2
ITEMS
Q’ty
APPLICATION ITEMS
Q’ty
APPLICATION ITEMS
Q’ty
APPLICATION
1MOUNTING PLATE
1
To mount the indoor unit on the
wall.
5DRY BATTERY
2For the remote control.
AAA batteries.
9REMOTE CONTROL
HOLDER 1
To mount the remote control on the
wall.
2WALL PLUG
9
To x the mounting plate with
the long screws. (7)
To x the remote control with
the special screw. (2)
6SPECIAL SCREW
(Black)
2
•
To mount the remote control
on the wall.
• To mount the remote
control holder on the wall.
10 MANUALS
1Installation manual
1Operation manual
3LONG SCREW
(M4.5x30) 7To x the mounting plate with
the wall plugs
.
7TERMINAL COVER
1
To cover the electrical cable.
11
AIR PURIFYING FILTER
2
To remove dust and tobacco
smoke from the air.
4REMOTE CONTROL
1 To control remotely.
8SHORT SCREW
(M4x12)
1
To secure the terminal cover.
12
SHEET(adhesive type)
1
To rmly secure the electrical cable.
A
B
B
The drain hose can be connec-
ted at either side of the indoor
unit.
Reposition the drain hose and
drain cap as required.
(1) Remove the xed screw in the
hose holder at the end of the
drain hose.
(2) Hold the end of the drain hose,
and pull it out.
(3) Pull out the drain cap.
(4) Reconnect the drain hose to
the right and insert the drain
cap to the left.
• Fully insert the drain hose until it
stops and use the screw that was
previously removed in STEP(1)
to secure the hose holder to the
drain pan.
• Insert a hexagon socket screw
key (4 mm diagonal) into the
drain cap, and press it fully.
Caution:
After replacing, make sure that both
the drain hose and drain cap are
rmly inserted.
ACCESSORIES
NOTES ON DRAIN HOSE
Drain hose
Hose holder
Hexagon socket
screw key
Drain cap
Drain hose
Screw
Drain cap
B593
OPER
INSTALL
INSTALLATION DIAGRAM
NOTES ON LOCATIONS
Indoor Unit
Indoor unit
1. Keep the air outlet clear of any obstacle
so that outgoing air ows smoothly in
the entire room.
2. Make a drain hose hole for easy drain-
age.
3. Provide sufcient space on both sides
and above the unit.
4. The air lters should be easily taken in
and out.
5. Keep TV set, radio and the like 1 m or
more away from the unit and the remote
control.
6. Keep the air inlet clear of obstacles that
could block incoming air.
7. The remote control may not function
properly in a room equipped with an
electronic simultaneous-start or rap-
id-start uorescent lighting.
8. Select a location that does not cause
loud operation noise and extreme vibra-
tions.
Outdoor unit
1. Place the outdoor unit on a stable base.
2. Provided sufcient space around the unit. It should also be
well ventilated.
3. The unit should not be exposed to strong wind nor
splashed with rain water.
4. Water drain from the unit should be let out without prob-
lem. Lay a drain hose if required. In cold regions, install-
ation of the drain pipe is not advisable as freezing could
result.
5. Keep TV set, radio and the like 1 m or more away from the
unit.
6. Avoid locations exposed to machine oil vapor, salty air
(facing the seashore, for example), hot spring vapor sulfur
gas, etc. Such location can cause breakdown.
7. Also, avoid locations exposed to muddy water (along a
road, for example) or where the unit can be tampered with.
8. Select a location where the outgoing air or operating noise
cannot annoy others.
9. Keep the air outlet opening free of any obstacle. This could
affect the performance of the unit and create loud noises. Outdoor Unit
Trap
SAFETY PRECAUTIONS
•Tightenthearenutwithatorquewrenchaccordingtothespeciedmethod.
If the are nut is tightened too hard, the are nut may be broken after a long time and cause
refrigerant gas leakage.
•Wheninstallingtheunit,takecarenottoenterairsubstanceotherthanthespeciedrefri-
gerant(R410A)intherefrigerantcycle.
Otherwise, it will cause burst and injury as a result of abnormal high pressure in the refrigerant cycle.
•Besuretoconnecttherefrigerantpipebeforerunningthecompressor.
Otherwise, it will cause burst and injury as a result of abnormal high pressure in the refrigerant cycle.
•Earththeunit.
Incomplete earth may cause electrical shock.
•Ifnationallegislationsortypeofinstallationrequiresearthleakagebreaker,thelegislation
mustbefollowed.
•Arrangethedrainhosetoensuresmoothdrainage.
Insufcient drainage may cause wetting of the room, furniture etc.
•ThisroomairconditionerusesrefrigerantR410A.
Use the pipe, are nut and tools exclusively for R410A.
•Installationmustbemadeinaccordancewiththeinstallationmanualby
qualiedser-
vicepersonnel
.
Incorrect work will cause electric shock, water leak, re.
• Besuretousetheattachedaccessoriespartsandspeciedpartsforinstallation.
Use of other parts will cause electric shock, water leak, re, the unit falling.
•Theapplianceshallbeinstalledinaccordancewithnationalwiringregulations.
Wrong connection can cause overheating or re.
•Afterinstallationhascomplete,checkthatthereisnoleakageofrefrigerantgas.
If the refrigerant gas contact with re, it may generate toxic gas.
•Ventilatetheroomifrefrigerantgasleaksduringinstallation.
If the refrigerant gas contact with re, it may generate toxic gas.
•Usethespeciedelectricalcable.
Make
sure the cable is secured
in place and that the terminals are free of any excess force
from the
cable. Otherwise overheating
or re may result.
•Formthecablesothatthecontrolboxcover,thecordholderandcableholderarenot
loose.
Otherwise overheating, re or electric shock may result.
SPLIT AIR/AIR HEAT PUMP
INSTALLATION MANUAL
Indoor Unit
12 THR-N AA/I
Outdoor Unit
12 THR-N AA/O
Max. piping length: A Max. height difference: B Min. piping length
15 m 10 m 3 m
• Additional refrigerant charge is not neccessary.
• Standard piping length is 5m.
• When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the
hose’s lead-in port.
Usetherefrigerantpipesshowninthetablebelow.
Pipe size Pipe thickness Thermal insulation
Liquid side 1/4" (ø 6.35 mm) 0.8 mm Thickness: 6 mm or thicker
Material: Polyethylene foam
Gas side 3/8" (ø 9.52 mm)
•
The thermal insulation should cover both the gas and liquid pipes.
PIPING
3
1
3
Provide as much installation
space as possible for efcient
air-conditioning.
MIN.20
MIN.120
MIN.50
MIN.50
Length unit: mm
Open panel
MIN.100
MIN.200
MIN.200
MIN.50
MIN.120
MIN.50
Drain cap Drain hose
(Recommended more than 100 mm)
12THR-N_IVT_final all.indd 2 2016/1/8 15:57:08