jablotron Futura User manual

Ventilation unit
with heat and moisture recovery
FUTURA
User manual


JABLOTRON FUTURA USER MANUAL
1/29 JABLOTRON LIVING TECHNOLOGY
TABLE OF CONTENTSTABLE OF CONTENTS
1. Introduction
1. Symbols used
2. Identification and application
3. Safety instructions
4. Heat recovery operation principle
5. Structural parts of the heat recovery unit
1. Unit body
2. LED indicator
3. Filters and filter replacement
4. Enthalpy exchanger
5. Fans
6. Summer bypass
7. Optional accessories
6. Unit operation modes
1. Stand-by
2. Constant power
3. Auto mode
4. Time schedule
7. Unit functions
1. Boost (forced ventilation)
2. Summer bypass
3. Night mode
4. Vacation
5. Party
6. Circulation
7. Overpressure
8. Anti-radon protection
9. Heating
10. Restart
11. Winter operation
12. Drying
1. Drying at extremely low outdoor temperature
2. Drying during prolonged low outdoor temperature
3. Drying after the fans have stopped
4. Icing protection
13. Functions, priorities and their response to simultaneous activation
8. Controlling the unit with Alfa control panel
1. Home screen
2. Quick access
3. Futura quick access screens
4. CoolBreeze quick access screen
5. Settings quick access screen
6. Error notifications on home screen
9. CoolBreeze Functions
1. Cooling and heating with CoolBreeze
2. Preferred and current temperature
3. CoolBreeze power output
4. Fan speed during CoolBreeze cooling/heating
5. Bypass

JABLOTRON FUTURA USER MANUAL
2/29 JABLOTRON LIVING TECHNOLOGY
6. Outdoor unit defrosting
7. Futura drying mode
10. Control of heat recovery unit
1. Local control
2. Remote control
3. Control using MyJABLOTRON mobile application
1. Login and basic control
2. Information about the unit
3. Advanced settings
4. Setting the Time schedule mode
4. Sharing access to Futura
11. Warranty
12. Disposal
1. Information for users regarding the disposal of electrical and electronic appliances (households)
2. Information for users regarding the disposal of electrical and electronic appliances (corporate and business)
3. Information regarding disposal of electrical and electronic items for users outside the European Union
Verze 3.0 EN

JABLOTRON FUTURA USER MANUAL
3/29 JABLOTRON LIVING TECHNOLOGY
11. . IntroductionIntroduction
Subject of this installation manual is Futura - ventilation unit with he at and mois ture recoveryFutura - ventilation unit with heat and moisture recove ry, which is designed for
controlled ventilation and treatment of the indoor environment of residential premises. The heat recovery unit ensures recovery
of heat and moisture, filters supplied air and helps maintain optimum air humidity. In summer, it provides additional cooling in
the night mode thanks to an integrated automatic bypass.
Before you put the heat recovery system in operation, read this User Manual carefully. It will provide you with information about
operational principles of heat recovery unit, its structural design, modes, functions, operation and maintenance.
Pay attention to all specifications and instructions included in this manual and follow them accordingly. This is the only way of
ensuring proper and safe operation of the heat recovery system.
This device complies with the Commission Regulation (EU) No 1253/2014 with regard to ecodesign requirements for ventilation
units and Commission Delegated Regulation (EU) No 1254/2014 with regard to energy labelling of residential ventilation units.
ANY CHANGES RESULTING FROM TECHNICAL DEVELOPMENT ARE RESERVED. WE RESERVE THE RIGHT TO CHANGE THE
CONTENTS OF THE MANUAL ANY TIME WITHOUT PRIOR NOTICE.
11..11. . Symbols usedSymbols used
Please, pay increased attention to the used symbols and in the interest of your safety and proper operation of the heat recovery
unit follow the instructions that accompany every symbol.
S ym b o lS ym b o l D esc ri pti o nD esc ri pti o n
IMPORTANT WARNINGIMPORTANT WARNING
CAUTION! IMMINE NT DANGE R!CAUTION! IMMINE NT DANGE R!
(risk of injury of the user or the service staff; risk of ventilation unit damage or disruption of its
proper function and operation)
CAUTION! ELECTRIC E QUIPMENT!CAUTION! ELECTRIC E QUIPMENT!
DANG E R! CAUT ION! RISK OF HAND INJURY!DANG E R! CAUT ION! RISK OF HAND INJURY!
22. . Identification and applicationIdentification and application
The Futura heat recovery unit represents HVAC device with heat recovery and an active control of moisture recovery. It has been
designed for comfortable and energy-efficient controlled ventilation of family houses. The heat recovery unit provides controlled
ventilation of residential premises with required ventilation volume of 100 – 350 m3 (3530 - 12360 ft3), at the outdoor air
temperature range from -19 °C to +45 °C (-2 °F to 113 °F). The unit can be used at the maximum relative indoor humidity level of
60 % at the temperature of 22 °C (72 °F).
Figure 1 – Identification label

JABLOTRON FUTURA USER MANUAL
4/29 JABLOTRON LIVING TECHNOLOGY
33. . Safety instructionsSafety instructions
Always follow the safety instructions that are included in this User Manual. Failure to observe them may result in personal injury
or damage of the heat recovery unit.
The unit has been designed and manufactured to provide controlled ventilation in residential buildings and premises.
The unit may only be used for purposes for which it has been designed and manufactured and for which it has adequate
technical capabilities – in line with the conditions defined by the manufacturer. Its design, construction and technical
condition complies with safety regulations.
The heat recovery unit must be installed in compliance with general and local safety regulations.
The heat recovery unit may only be installed, connected, commissioned and maintained by an authorized service technician
with respective professional qualifications. A service technician is a person with adequate qualifications, experience and
knowledge of respective regulations, standards as well as possible risks and dangers.
The unit may only be independently operated by physically and mentally apt persons that have thoroughly read and
understood the User Manual. The User Manual must be stored in an accessible place.
Do not change or modify the heat recovery unit in any way!
Follow the time intervals for regular filter replacement.
Do not repair the heat recovery unit! If you find a defect or damage contact a service technician immediately.
We do not recommend leaving the heat recovery system off for prolonged periods, not even in the of absence of persons.
Always let the system run at the lowest ventilation level or in the Automatic Mode.
The unit can not be used while there is still unfinished construction work in the building. The unit must be installed and
commissioned in a finished and clean building.
The heat recovery unit is designed for joint operation with a fireplace only when the fireplace is suitable for passive buildings,
has a sealed fireplace insert and its own air supply.
Joint operation with a fireplace is possible only if relevant safety and fire regulations are followed. Such operation requires
setting and using the Overpressure function (see Heat recovery unit functions).
The s ys tem must not be ope rated toge ther with an ope n fireplace or with any fire place w ithout itsThe s ys tem must not be ope rated toge ther with an ope n fireplace or with any fire place w ithout its
ow n air supply!ow n air supply!
The unit mus t be off and dis connected from electrical mains during any maintenance including filterThe unit mus t be off and dis connected from electrical mains during any maintenance including filter
re place ment!re place ment!
Do do not reach into the filter space w ith your hand when replacing filters! Avoid risk of hand injury!Do do not reach into the filter space w ith your hand when replacing filters! Avoid risk of hand injury!

JABLOTRON FUTURA USER MANUAL
5/29 JABLOTRON LIVING TECHNOLOGY
44. . Heat recovery operation principleHeat recovery operation principle
The heat recovery system ensures continuous replacement of used air with fresh, clean air. Heat recovery takes place in the
exchanger, where the supplied air receives part of heat and humidity from extracted air (mainly from kitchen, bathroom etc.).
Therefore fresh air which continuously flows into the interior (living room, children’s rooms, guest bedroom, office etc.) is
thermally optimized. The fresh air is also filtered before it is supplied. To prevent dust buildup on fan blades the extracted air is
filtered as well. The two air streams are separated so that fresh and used air do not mix.
An automatic bypass enabling after-cooling during summer months (in the night mode) is integrated in the heat recovery unit. As
heat recovery is not desirable during summer the bypass channel directs extracted air outside of the exchanger and thus
prevents cooler night air from being heated up by the warm extracted air.
Figure 2 – Heat recovery principle

JABLOTRON FUTURA USER MANUAL
6/29 JABLOTRON LIVING TECHNOLOGY
55. . Structural parts of the heat recovery unitStructural parts of the heat recovery unit
The heat recovery unit consists of the following structural parts:
ABCD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Figure 3 – Unit structure
A - Outdoor air
B - Waste air
C - Supplied air
D - Indoor air
De scription:De scription:
1 - Outdoor air filter
2 - Terminal
3 - Main board
4 - Bypass servo
5 - T & RH waste air sensor
6 - Circulation servo
7 - T & RH outdoor air sensor
8 - IO board
9 - Extracted air filter
10 - Mains supply and fuse
11 - Power board
12 - Power supply
13 - T & RH supply air sensor
14 - T & RH extract air sensor
15 - Comfortable post-heating
16 - Condensate drain
55..11. . Unit bodyUnit body
Outer jacket of the heat recovery unit is made of durable plastic. The internal structure is made of monolithic polypropylene,
which serves as heat and noise insulation without thermal bridges. The orifices of the heat recovery unit (∅ 150 mm) for air supply
and exhaust are situated in its top part.

JABLOTRON FUTURA USER MANUAL
7/29 JABLOTRON LIVING TECHNOLOGY
55..22. . LED indicatorLED indicator
LED indicator is located on the front cover of the unit. It provides a visual indication of unit's current status. During normal
operation green light pulses in regular intervals. A change in the LED color indicates an error notification, need to replace filters or
Bluetooth activation. All color indications are described in the following table.
Co l o r RGB LEDCo l o r RGB LED Descriptio nDescriptio n
green Constant power, Automatic mode, Stand-by
Yellow Replace filters! Filters are clogged!
Red Error! Fault!
Blue Active Bluetooth
Pleas e pay atte ntion to the changes in LED indicator.Pleas e pay atte ntion to the changes in LED indicator.
55..33. . Filters and filter replacementFilters and filter replacement
The heat recovery unit contains F7 filters at the air supply as well as exhaust. The need to replace the filters is indicated
automatically. Recommended frequency of their replacement depends on the air quality in the environment where the unit is
used (1× approx. 2 – 6 months). Basic filtration can be supplemented with an optional carbon filter, which is inserted directly into
the unit under the supplied air filter.
Users are alerted to the need to replace filters by:
a change of the color of LED indicator on the front side of the unit (see the preceding table),
a notification in MyJABLOTRON mobile application,
a notification "Filte r""Filter" and a warning symbol on the control panel
Do not reach into the filter s pace with your hands w he n replacing filte rs ! Avoid the ris k of handDo not re ach into the filte r space w ith your hands w he n replacing filte rs ! Avoid the ris k of hand
injury!injury!
Never use your he at recove ry unit without filters ! The unit must be off during maintenance and filterNeve r us e your heat re covery unit without filters ! The unit must be off during maintenance and filter
re place ment!re place ment!
When replacing filters proceed as follows:
use On/Off button the switch the heat recovery unit off,
remove cover from filter drawer and pull filters out of the drawer,
insert a new filter into the drawer and place the cover back in its place, make sure to insert filters correctly, observing the
arrows indicating air flow direction!
switch the heat recovery unit on using the On/Off button
press filter initialization button on the control board (see fig. 4 – Filter initialization) or start filter replacement in
MyJABLOTRON application.
New filters mus t be ins erted in both filter draw ers and filter covers mus t be placed back be foreNew filters mus t be ins erte d in both filter draw ers and filter covers mus t be placed back be fore
initialization proces s! Do not us e any other filters than those s upplied by the manufacturer and doinitialization proces s! Do not us e any other filters than those s upplied by the manufacturer and do
not add any extra prefilters !not add any extra prefilters !

JABLOTRON FUTURA USER MANUAL
8/29 JABLOTRON LIVING TECHNOLOGY
XX 22 XX 33 XX 44 XX 55 XX 66
TT11
GGNNDD
XX 11
LLAANN RRSS-- 448855 EExx tt RRSS-- 448855 PPeerr NNTTCC AA AA
But t o nBut t o n
AA++
BB--
AA++
GGNNDD
++2244VV
GGNNDD
NNTTCC
LLEEDD
BBSSTT
GGNNDD
AAAA
AAAA
BB--
I N 1I N 1
I N 2I N 2
I N / O U TI N / O U T
Figure 4 - Filter initialization - short press
After new filter initialization the unit will return to its previous setting.
Figure 5 – Filter change
Clogge d filters that are not replaced re gularly may caus e gre ater pre ss ure los s , poor airflow andClogged filte rs that are not replaced regularly may caus e greater pres s ure los s, poor airflow and
accumulation of dus t on fan blades which hinde rs their functionality. Clogge d filters also increas eaccumulation of dus t on fan blades which hinde rs their functionality. Clogge d filters also increas e
pow er consumption and output of fan motors . This res ults in exces s ive w ear, sys te mic imbalancepower cons umption and output of fan motors . This res ults in exces s ive we ar, sys te mic imbalance
and imprope r operation of heat recovery s ys tem in ge neral. In an extre me cas e this m ay lead toand imprope r operation of heat recovery s ystem in ge neral. In an e xtreme case this may le ad to
irrevers ible damage and impaired functionality of comfortable ve ntilation.irrevers ible damage and impaired functionality of comfortable ve ntilation.
Replace filters on regular bas is!Replace filters on regular bas is!
55..44. . Enthalpy exchangerEnthalpy exchanger
Futura heat recovery unit is equipped with an enthalpy counter-current exchanger. Apart from transferring heat from exhausted
air it is also capable of transferring humidity, thus optimizing indoor environment humidity levels.
55..55. . FansFans
Futura heat recovery unit contains two efficient fans with an integrated electronic unit and the function of maintaining a constant

JABLOTRON FUTURA USER MANUAL
9/29 JABLOTRON LIVING TECHNOLOGY
air flow.
55..66. . Summer bypassSummer bypass
Summer bypass is a supplementary bypass channel that directs supplied air around the exchanger during cooler summer nights.
This prevents warm exhausted air from transferring its heat to cooler outdoor air and heating it up. Bypass works in an automatic
mode and its use is based on the temperature setpoint. Bypass is not used at an outdoor temperature lower than +8 °C, during
active Drying, Circulation or Stand-by. Automatic bypass function can be enabled or disabled in a mobile application.
55..77. . Optional accessoriesOptional accessories
The heat recovery system can be supplemented with following optional accessories - CO2 sensors (up to 8 pieces), Alfa control
panels (up to 8 pieces), VAC material and distribution elements.
66. . Unit operation modesUnit operation modes
66..11. . Stand-byStand-by
When the heat recovery unit is in Stand-by mode, the air exchange is not active. Information from all the connected sensors is
available, being continuously evaluated. Thanks to connection to Jablotron Cloud, the heat recovery unit can be activated and its
settings can be changed any time. The unit in Stand-by mode responds to Boost function.
66..22. . Constant powerConstant power
Constant power mode lets user adjust level of fan speed (levels 1 – 5). Depending on the temperature and humidity setpoint, the
system controls the bypass flap and connected peripherals. It controls turning of the heat exchanger flaps and drying flap based
on the current temperature and humidity.
66..33. . Auto modeAuto mode
Default mode of the heat recovery unit. This mode uses information from the connected CO2 sensors and controls fan speed
based on updated values. The ventilation output is adapted to the requirements for quality of the indoor environment. The unit
remains in this mode until it is switched to the Time Schedule mode. The sensors control the operation of the heat recovery unit
automatically; fan speed is adjusted according to data from sensors. There can be up to 8 CO2 sensors connected to the unit and
the HVAC technician can set which ones will be used to control the fan speed.
66..44. . Time scheduleTime schedule
A mode in which user schedules switching between Automatic Mode, Stand-by Mode or a preset fan speed within a range of
five levels: 1 (minimum) – 5 (maximum). Time schedule can be activated or deactivated. If Time schedule is activated while one
of the functions is running, the function is immediately deactivated and the unit starts to run according to the Time schedule
mode. However, Time schedule mode cannot be activated while the Vacation function is on.
77. . Unit functionsUnit functions
77..11. . Boost (forced ventilation)Boost (forced ventilation)
A top speed (5) function used if a fast, forced ventilation of the indoor premises is required. The unit is temporarily switched to
the maximum level, the fans working at the top speed. This function is available in any mode. It can be activated from the mobile
application (for any time interval), from the wall-mounted control panel (for a preset interval) or with a Boost switch connected to
the unit (for two preset intervals, one for short press and one for a 3 second long press). Boost switches are typically installed in
rooms where forced ventilation is needed, such as bathroom, toilet or kitchen. The time interval for Boost switch (for both short
and long press) can be adjusted, but only by the HVAC technician. If Boost is active, the time remaining until the expiration of this
function is displayed next to the respective symbol. After expiration of the given time, the unit returns to the previous mode.
77..22. . Summer bypassSummer bypass
Summer bypass consists of a supplementary bypass channel that directs the supplied air around the exchanger, namely during

JABLOTRON FUTURA USER MANUAL
10/29 JABLOTRON LIVING TECHNOLOGY
cooler summer nights. This prevents the warm exhausted air from transferring the unwanted heat to the colder air from the
outside and heating it up
77..33. . Night modeNight mode
A reduced power function used at night. The unit is switched to the minimum level (1), the fans working at the lowest power
setting. After expiration of the given time, the unit will return to the previous mode.
77..44. . VacationVacation
A reduced power function used in periods of absence of the users on the premises. The unit is switched to the minimum level
(1), the fans working at the lowest power setting.
77..55. . PartyParty
An increased power function used mainly when more people are present on the premises. The unit works at the 4th power
setting. After expiration of the set time the unit will return to the previous mode.
77..66. . CirculationCirculation
A function used if it is necessary to prevent flowing of outdoor air into the indoor space. The indoor air is circulated. Upon setting
this function, the user sets the duration of this function.
77..77. . OverpressureOverpressure
A function designed for simultaneous use with a fireplace. The unit changes the ratio of the fan speeds for the aspirated and
exhausted air. The fan exhausting air from the indoor space works at a lower speed than the fan that supplies air. This prevents
combustion products and smoke from getting into the interior.
77..88. . Anti-radon protectionAnti-radon protection
A function for permanent radon protection of the premises. Similar to the Overpressure function, it changes the fan speeds for
the fresh and exhausted air. The fan exhausting air from the indoor space works at a lower speed than the fan that supplies fresh
air. This prevents radon from leaking indoors. This function can be actived only from the mobile application. The overpressure
ratio is set by the HVAC technician and the function is permanent until its deactivation in the mobile application.
77..99. . HeatingHeating
The heat recovery unit can heat the supplied fresh air by means of an internal heater. The heater output is controlled based on
temperature of exhaust air. This feature can be turned on or off from a mobile application. The heat recovery unit is not intended
as a primary source of heating!
77..1010. . RestartRestart
The following user functions are reactivated after the restart of the unit or after a power outage:
Ventilation
Time schedule settings
Vacation
Anti-radon protection
Fan speed for different levels (1-5)
Overpressure settings
Temperature setpoint
Humidity setpoint
Ventilation settings in Auto mode
Boost duration
IN1 and IN2 input settings
Heating permission

JABLOTRON FUTURA USER MANUAL
11/29 JABLOTRON LIVING TECHNOLOGY
Cooling permission
Automatic bypass permission
The following functions are deactivated after restart:
Boost
Circulation
Overpressure
Night mode
Party
Drying
Filter check
Shutdown
Servicing mode
Bluetooth permission
77..1111. . Winter operationWinter operation
Winter operation is started automatically when the average temperature of exhausted air drops below -3 °C (27 °F). Winter
operation prevents fans from stopping while the unit is in the Auto mode running according to data from the CO2 sensors. During
winter operation, the fans do not stop. Their speed decreases to Level 1 instead. When the unit is switched into the winter
operation while the circulation mode is on, the circulation mode is deactivated.
77..1212. . DryingDrying
The heat recovery unit is technically as well as structurally ready for operation at temperatures below the freezing point without
the need of preheating down to -19 °C (-2 °F). When the outside temperatures remain below freezing point, the unit may
occasionally switch into drying mode. This mode removes excess moisture from the unit. It is fully automatic, the unit activates
drying mode as necessary according to operation logic evaluation. The time span between two drying cycles is not fixed.
Drying lasts three hours.
The flaps of the heat exchanger are further turned over in intervals determined by the dew point temperature.
Heating (internal or CoolBreeze) is turned on the maximum.
The bypass flap is shut and the circulation flap is open.
The speed of both fans is set to 20%. Balancing of the pressure is not active, but the
Overpressure
mode and
Anti-radon
Protection
mode stay on.
Too low Outdoor Temperature
and
Settings
symbols are displayed on the wall-mounted control panel.
Thanks to this function no other frost protection in the form of electric preheating is necessary. During this mode, the user
comfort is not reduced; the air that is supplied to the indoor space is warmer than the air that is exhausted. If the Boost function
is activated during drying, the forced exhaust time is limited to 2 minutes. The drying mode cannot be deactivated by the user
and in case of a power outage, the drying mode is resumed after the unit is on.
7.12.1. Drying at extremely low outdoor temperature
A mode started automatically when the outdoor temperature drops and remains below -20 °C (-4 °F) for 16 minutes. This mode is
deactivated when the temperature rises to -18 °C (0 °F).
Too low Outdoor Temperature
and
Warning
symbols are displayed on
the wall-mounted control panel. After the drying is finished, the ventilation and filter check are blocked, Boost is limited to 2
minutes, the unit continues to run in the Circulation mode.
7.12.2. Drying during prolonged low outdoor temperature
Drying mode is activated when the temperature of exhausted air drops below -5 °C and does not rise above -1 °C during the
following 72 hours. In case of a restart or a power outage the elapsed drying time is saved and when the unit is back on, the
drying mode is resumed for the remaining period of time.
7.12.3. Drying after the fans have stopped
When the fans stop running for 35 seconds or longer, while the temperature of the exhausted air is below 0 °C, the drying is
activated.

JABLOTRON FUTURA USER MANUAL
12/29 JABLOTRON LIVING TECHNOLOGY
7.12.4. Icing protection
Icing protection is activated when the average temperature of the exhausted air is below -3 °C. Icing protection blocks Time
schedule mode, Auto mode (in case the unit is controlled by CO2 sensors) or analogue voltage input from stopping the fans.
Instead of stopping, the fans continue to run at Level 1 speed. This action can be seen in the mobile application. Icing protection
also blocks Circulation mode.
77..1313. . Functions, priorities and their response to simultaneous activationFunctions, priorities and their response to simultaneous activation
When a certain function of the heat recovery unit has been activated, you can activate another function - that will either
deactivate or interrupt the previous function, or the functions will run simultaneously. Each function and mode has a defined
priority in relation to other functions. The functions and modes are prioritized in the following order:
Emergency mode
Boost
Party
Night mode
Vacation
Manual setting (level 1-5) or Time schedule mode
Auto mode (CO2 or analogue input)
Circulation, Overpressure and Anti-radon can run simultaneously with any of the above-mentioned modes/functions, but they
cannot run simultaneously with each other. They are prioritized in the following order:
Circulation
Overpressure
Anti-radon
The BoostBoos t function interrupts the CirculationCirculation function. The Night modeNight mode and PartyParty functions will resume after expiration of
the BoostBoos t function. If the Boos tBoost function is started and the VacationVacation function has also been selected (both symbols are lit), the
VacationVacation function will resume once Boos tBoos t function expires. Boos tBoost is available in any mode.
Selecting the Night ModeNight Mode deactivates BoostBoos t and Party.Party.
Selecting the VacationVacation function deactivates Boos t, Night ModeBoos t, Night Mode and Circulation.Circulation.
Selecting the PartyParty function deactivates Boost, Night modeBoost, Night mode and Circulation.Circulation.
PartyParty function cannot be activated while the VacationVacation function is active.
When the ventilation is controlled by analogue inputanalogue input with voltage of 1-10 V, it overrides the CO2 controlled ventilation.
Selecting the Time sche duleTime s chedule deactivates all of the other running functions and the unit starts running according to the
Time scheduleTime schedule settings. T ime scheduleTime schedule is not available while the VacationVacation function is active.
Pressing the Boos tBoost button repeatedly does not cancel, but prolongs the function.
Selecting Overpress ureOverpres s ure while the Boos tBoost function is on does not cancel the BoostBoos t function. The fan speed ratio is adjusted
according to the Ove rpres s ureOverpres sure ratio and the unit continues to run in Boost.Boost.
Selecting the Boos tBoost while the Overpres s ureOverpres sure is active does not cancel Ove rpres s ureOverpres sure . The BoostBoos t is activated while the
unit continues to operate at the Ove rpres s ureOverpres sure fan speed ratio.
Boos t, Overpres sure, CirculationBoos t, Overpres sure, Circulation have the option of setting a delayed start or stop.

JABLOTRON FUTURA USER MANUAL
13/29 JABLOTRON LIVING TECHNOLOGY
88. . Controlling the unit with Alfa control panelControlling the unit with Alfa control panel
Alfa control panel is a standard joint control panel for Jablotron Living Technology systems. Its operation starts on home screen.
88..11. . Home screenHome screen
Figure 6 – Home screen icons
1 - Set ventilation level
2 - Connected to cloud
3 - Temperature setpoint
4 - Actual temperature
5 - CoolBreeze output
6 - Actual local humidity
7 - Actual local CO2
8 - Outdoor humidity
9 - Outdoor temperature
Home s cree n quick accessHome s cree n quick access
User can set quick access for temperature setpoint or ventilation level. Turning the control dial provides a primary quick access
and enables user to adjust the desired value (temperature or ventilation level, depending on the setting). The new value is saved
automatically after three seconds of inactivity. In the Settings menu the user can set whether primary quick access will be
assigned to temperature setpoint or ventilation level.
Secondary quick access (e.g. for ventilation level if the temperature is set as the primary quick access) is displayed by pressing
and holding the dial. Subsequent turning of the control dial enables the user to adjust the given value (temperature or ventilation

JABLOTRON FUTURA USER MANUAL
14/29 JABLOTRON LIVING TECHNOLOGY
level, depending on the setting). After three seconds of inactivity the value is saved and the secondary quick access indication
disappears from home screen.
Dis playing subs ys te m valuesDis playing subs ys te m values
If a subsystem is available, its current value with respective unit is displayed below its icon. If the subsystem is not available, its
icon is displayed in grey and –– is displayed instead of the value. In case CoolBreeze is connected, the system displays icon of the
current mode (cooling/heating - snowflake/flame and breeze icon). If CoolBreeze is not connected, the snowflake/flame icon is
displayed in grey.
88..22. . Quick accessQuick access
Pressing the dial on the home screen displays menu with icons for individual subsystems, a "Home screen" icon and a "Settings"
icon. In case a particular subsystem is not connected to the system, its icon is displayed in grey and the icon is skipped when the
dial is turned.
Figure 7 – Quick access tab icons - active ventilation
1 - CoolBreeze
2 - Cooling
3 - Heating
4 - Home screen
5 - Ventilation
6 - Hot water
7 - Settings
Active icon is inverse - home screen is lit.
Turning the dial scrolls through the menu items.
Clicking on a highlighted item opens its respective screen.
Clicking on the house icon hides the menu and displays the home screen.
Menu timeout is five seconds - after five seconds of inactivity the display returns to home screen automatically. The timeout
is reset when the dial is manipulated.
Icons in the menu that are not active are displayed in grey and skipped when scrolling. Hot water, Cooling or Heating is only

JABLOTRON FUTURA USER MANUAL
15/29 JABLOTRON LIVING TECHNOLOGY
displayed when the subsystem is connected.
Scrolling through itemsScrolling through items
Unless the subsystem is in the Stand-by state, “Operating Mode” is highlighted by default when entering the Quick Access
screen. The currently highlighted item is indicated by a bold black frame. If the item's value can be changed, small arrows appear
above and below the item. Turning the dial clockwise moves the highlight in the following order: "Ventilation level",
"Temperature setpoint", "Humidity setpoint", "Next page", "Back", "Stand-by" and again "Operating mode". Turn the dial counter-
clockwise to scroll through items in reverse order.
If the subsystem is in the Stand-by mode, the Stand-by button is highlighted by default when entering the Quick Access screen.
The subsystem items are displayed in grey and show only the most recent status of the subsystem. Turning the dial scrolls
through “Next Page” (or “Previous Page”), “Back” and “Stand-by” elements, subsystem items are skipped.
Figure 8 – Scrolling through items
How to s elect an item and adjust its valueHow to s elect an item and adjust its value
If the currently highlighted item allows the value to be adjusted, small grey arrows appear above and below. Clicking on the item,
its icon and the arrows blacken and the value can be changed. Turning the dial adjusts the value of the item within the defined
step and range. Subsequent click confirms the new value. This action will highlight the menu item again and enable the user to
scroll to other items. Pressing and holding the dial saves new settings. New settings are also saved automatically after ten
seconds of inactivity and the quick access screen is displayed.

JABLOTRON FUTURA USER MANUAL
16/29 JABLOTRON LIVING TECHNOLOGY
Figure 9 – Adjusting the value of selected item
88..33. . Futura quick access screensFutura quick access screens
Futura has three basic quick access screens. Their description is stated below.
Figure 10 – First quick access screen
Operation modeOperation mode (adjustable item). Current ventilation mode. Icon shows current ventilation mode (Manual/Time
Schedule).
Ventilation levelVentilation level (adjustable item). Ventilation level. Icon shows current ventilation level.
Tempe rature se tpointTempe rature se tpoint (adjustable item). Preferred temperature setpoint. Icon shows preferred temperature for bypass or
heating.
Humidity s etpointHumidity s etpoint (adjustable item). Preferred relative humidity setpoint. Icon shows preferred humidity (each value has
its individual icon).

JABLOTRON FUTURA USER MANUAL
17/29 JABLOTRON LIVING TECHNOLOGY
Figure 11 – Second quick access screen
Circulation.Circulation. Click to display the Time Setting Screen (Quick Access). The icon shows whether the Circulation function is
active. If active, the Circulation icon is displayed along with remaining time (HH:MM). If the Circulation function is not active,
only the circulation icon is displayed.
Boos t.Boos t. Click to display the Time Setting Screen (Quick Access). The icon shows whether the Boost function is active. If
active, the Boost icon is displayed along with remaining time (HH:MM). If the Boost function is not active, only the Boost icon
is displayed.
Overpres s ure.Overpres s ure. Click to display the Time Setting Screen (Quick Access). The icon shows whether the Overpressure function
is active. If active, the Overpressure icon is displayed along with remaining time (HH:MM). If the Overpressure function is not
active, only the Overpressure icon is displayed.
Night Mode.Night Mode. Clicking this item displays the Time Setting screen (Night Mode page 1). After confirmation (Night Mode page
2) the mode is enabled. Clicking the cancel button disables the night mode. The icon shows whether Night mode is enabled,
the item shows Night mode icon and the time from-to “HH:MM-HH:MM”. If night mode is not enabled, only the Night mode
icon is displayed.
Figure 12 – Third quick access screen

JABLOTRON FUTURA USER MANUAL
18/29 JABLOTRON LIVING TECHNOLOGY
Vacation.Vacation. Click this item to display the Time Setting Screen (Day/Hour). The icon shows whether Vacation mode is active,
the item shows Vacation icon and the time to end (DDd HHh). If Vacation mode is not active, only Vacation icon is displayed.
The "Stand-by" and " Info" buttons are ide ntical for all three s cre ens . Clicking the “Stand-by” button turns theThe "Stand-by" and " Info" buttons are ide ntical for all three s cre ens . Clicking the “Stand-by” button turns the
Stand-by mode on or off. T urning Stand-by mode on w ill dis able quick acce ss ite ms.Stand-by mode on or off. T urning Stand-by mode on w ill dis able quick acce ss ite ms.
The unit goes to Stand-by immediate ly upon clicking the dial - unlike adjus table ite ms that are s et by turningThe unit goes to Stand-by immediately upon clicking the dial - unlike adjus table ite ms that are set by turning
the dial.the dial.
88..44. . CoolBreeze quick access screenCoolBreeze quick access screen
To quickly access CoolBreeze click on its icon. The icon in the menu bar will be highlighted and framed. The header and body of
the screen turns into CoolBreeze quick access. The highlight moves to the first item on the left - “Operation Mode” or “Stand-by”
when the unit is in the Stand-by mode.
Figure 13 – CoolBreeze quick access screen
Scrolling through CoolBreeze me nuScrolling through CoolBreeze me nu
The logic of scrolling through CoolBreeze menu is the same as scrolling through the quick access of Futura. Turning the dial
clockwise moves the highlight in the following order: "Set temperature", "Back", "Stand-by" and again "Operating mode". The
"CoolBreeze power indication" item is skipped. Turning the dial counter-clockwise scrolls the highlight in the reverse order.
How to s elect an item and adjust its valueHow to s elect an item and adjust its value
The logic of changing values in CoolBreeze quick access is the same as in the Futura quick access.
CoolBre eze menu des criptionCoolBre eze menu des cription
„Stand-by“ button.„Stand-by“ button. The CoolBreeze goes to Stand-by mode immediately after clicking the dial - unlike adjustable items that
are set by turning the dial. Stand-by button turns the Stand-by CoolBreeze mode on or off. Turning on the Stand-by mode
disables the CoolBreeze quick access items. When the icon is black - CoolBreeze is in Stand-by mode; when the icon is light -
CoolBreeze is running.
CoolBre eze Operating modeCoolBre eze Operating mode (adjustable item). Setting the current CoolBreeze operating mode. The icon displays the
current CoolBreeze operating mode. Cooling (flake and breeze symbol) - heating (flame and breeze symbol).
Tempe rature se tpointTempe rature se tpoint (adjustable item). Preferred temperature setpoint - icon displays set preferred temperature.
„Back“ button.„Back“ button. Clicking this item will move the highlight to the menu bar of the CoolBreeze subsystem.