2
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (PA-1) (RACKS/HOUR)
RACKS PER HOUR 40
RACKS PER HOUR (OPTION) 48
DISHES PER HOUR 1000
GLASSES PER HOUR 1000
OPERATING CAPACITY ( PA-1V) (RACKS/HOUR)
RACK PER HOUR 28
DISHES PER HOUR 700
GLASSES PER HOUR 700
OPERATING CAPACITY (PA-2’s) (RACKS/HOUR)
RACKS PER HOUR 80
RACKS PER HOUR (OPTION) 96
DISHES PER HOUR 2000
GLASSES PER HOUR 2000
OPERATING CYCLE (PA-1) (SECONDS)
WASH TIME 40
RINSE TIME 15
TOTAL CYCLE TIME 90
TOTAL CYCLE TIME (OPTION) 72
OPERATING CYCLE (PA-1V) (SECONDS)
WASH TIME 40
RINSE TIME 15
TOTAL CYCLE TIME 120
OPERATING CYCLE (PA-2’s) (SECONDS)
WASH TIME 35
RINSE TIME 20
TOTAL CYCLE TIME 90
TOTAL CYCLE TIME (OPTION) 72
TUB CAPACITY (GALLONS)
WASH TUB (MINIMUM) (PA-1’s) 1.7
WASH TUB (MINIMUM) (PA-2’s) 3.1
WASH PUMP CAPACITY
GALLONS PER MINUTE 61
TEMPERATURES
WASH---°F (MINIMUM) 120
WASH---°F (RECOMMENDED) 140
RINSE---°F 120
RINSE---°F (RECOMMENDED) 140
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER (PA-1) 3/4
(2) WASH PUMP MOTOR HORSEPOWER (PA-2’s) 3/4 ea.
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec-
tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim-
ply for reference and may change without notice at any
given time.
TYPICAL
TOTAL ELECTRICAL
VOLTS HERTZ PHASE AMPS CIRCUIT
PA-1’s 115 60 1 12.0 15 AMP
PA-2’s 115 60 1 23.0 30 AMP
WATER REQUIREMENTS
INLET TEMPERATURE (Minimum) 120°F
INLET TEMPERATURE (Recommended) 140°F
GALLONS PER HOUR (PA-1’s) 68
GALLONS PER HOUR (PA-2’s) 160
GALLONS PER HOUR (PA-2’s) (OPTION) 192
WATER LINE SIZE NPT (Minimum) 3/4”
DRAIN LINE SIZE NPT (Minimum) 2”
FLOW PRESSURE P.S.I. 20±5
MINIMUM CHLORINE REQUIRED (PPM) 50
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS
PA-1/PA-2 Series Installation & Operation Manual
7610-002-24-11 Rev. J (11/02/2005)