JCM Technologies KEEROLL User manual

KEEroll
User Manual

Table of contents
Important safety instructions 4
Safety instructionsfor installation 4
Safety instructionsfor the use 5
Use of the equipment 5
Introduction 6
KEEroll 6
Indicators 6
Actions 7
RadioSens3 System 8
Batterylife 8
RadioBand3 System 9
KEEpad & KEEpush 10
KEEpad 10
KEEpush 10
KEEalarm 11
SESAME 11
SESAMEfeatures 11
KEEroll 12
Installation 12
Control panel fixations 12
Connections 13
Configuration / Starting up 15
Connect the power supply 15
Adjusting limit switch 15
Optionsselection 15
Set courtesy light 16
Programming 16
Transmitter programming 16
Manoeuvre programming 17
Verification 18
Verify that the control panel is working properly 18
Communication’s quality 18
Maintenance 19
Program maintenance manoeuvres 19
Reset manoeuvres counter 19
Reset transmitters 19
Reset safety elements 20
Fuse replacement 20
Troubleshooting 21
Technical Data 21
RadioSens3 System 22
Installation 22
Impact detection adjustment 23
Programming 23
Maintenance 23
jcmtechnologies
2

Batteriesreplacement 23
Troubleshooting 24
Technical Data 24
RadioBand System 25
Installation 25
Connection 25
Programming 28
Maintenance 29
Ledsand beepsindication table 29
Replacing the transmitter battery 29
Technical data 30
KEEpad & KEEpush 31
Installation 31
Programming 32
KEEpad 32
KEEpush 32
Verification 33
KEEpad 33
KEEpush 33
Maintenance 34
Batteriesreplacement 34
KEEpad 34
Troubleshooting 36
Technical Data 37
KEEalarm 38
Programming 38
Installation 39
Verification 39
Maintenance 39
Deactivate the alarm 39
Rearm the alarm 39
SESAME 40
Connections 40
Configuration 40
Set up WiFi connection 40
Configure SESAMEin "Honoa" 41
Verification 44
Maintenance 44
Resetting the device 44
LED behaviour 45
Notes 46
Regulatory Data 48
EU Declaration of conformity 48
jcmtechnologies
3

Important safety instructions
Safety instructions for installation
Disconnect the power supply whenever you proceed to the installation,
maintenance or repair of the equipment.
•Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as locks that is not
necessary for the automatic operation.
•Before installing the panel, check that the door is in good mechanical condition, correctly balanced and that it opens and
closes correctly.
•Install the manual unlocking device at a height lower than 1.8m.
•Install any permanent control next to the door away from any moving part and at a minimum height of 1.5m.
•For permanently connected equipment, an easily accessible power disconnection device must be incorporated into the wir-
ing. It is recommended that this be of the emergency switch type.
•If the control panel is supplied without emergency stop button, this will be incorporated in the installation, connecting it to
the STOP terminal.
•For correct use of the security edge, this must never be activated when the door is fully closed. It is wise to install the ends
of run before activating the edge.
•This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained operator.
•To connect the power supply and motor wiring, 2.5 mm2 section terminals must be used.
•Use protective goggles when handling the equipment.
•Fuses must only be handled when the appliance is disconnected from the mains.
•The instructions for using this equipment must remain in the possession of the user.
•European door normative EN 12453 and EN 12445 specify the following minimum protection and door safety levels:
- for single-family dwellings, prevent the door from making contact with any object or limit the force of contact (e.g. safety
band), and in the case of automatic closing, it is necessary to complement this with a presence detector (e.g. photocell).
- for communal and public installations, prevent the door from making contact with any object or limit the force of contact
(e.g. safety band), and complement this with a presence detector (e.g. Photocell).
WARNING: IN ACCORDANCE WITH THE EN 13241-1 AND EN 12453-1 STANDARD
CONCERNING PRESSURE MAINTAINED CONTROL DEVICES:
“The person operating the door must have a direct view of the doorway, must be near the door (5 meters maximum) during
movement of the door and should not find itself in a dangerous position”. Any adjustment of the radio range out of these
recommendations, undertakes the installer in terms of responsibility for injury or damage.
“Releasing of the pressure maintained control device should stop the door movement before it scrolls 5cml”.
jcmtechnologies
4

Safety instructions for the use
•Do not allow children to play with the door controls.
•Keep the remote controls out of the reach of children.
•Watch the door movement and keep people away until the door is fully open or closed.
•Precaution when operating the manual unlocking device, as the door may suddenly fall due to the bad condition of the
springs or door unbalance. Details on how to use the manual unlocking device must be provided by the manufacturer or the
device installer.
•Examine the installation frequently, especially the cables, springs and supports, to detect signs of wear, damage or unbal-
ance. Do not use the door if repair work or adjustments are required, as this may cause damage.
Use of the equipment
Designed for automation of garage doors, in accordance with the general description. Not guaranteed for other uses. The
manufacturer reserves the right to alter equipment specifications without prior notification. No liability can be accepted for
errors and misprints.
jcmtechnologies
5

Introduction
KEEroll
Designed for residential aluminium roller shutters, the KEEroll solution has direct communication with the user and the
installer.
Its capacitive front with illuminated keys provides comfort and security. The door can be opened and closed by any person
without the need for technical know-how. The installer requires no initial training in the product.
The control panel can incorporate the most advanced system for detecting obstacles via radio, without wires. Ready to work
with RadioBand3 or RadioSens3 tocomply with all safety regulations. It'sclean, quick and straightforward.
The system complies with standard EN ISO13849-1: 2008, category 2, PLc.
Indicators
jcmtechnologies
6

Actions
Press to open, stop and close the door.
Press to close the door in dead man mode.
Block transmitter function: KEEroll control panel incorporatesa block button on the cover to
prevent the door from being opened accidentally.
Press to block the door, key lights on. The control panel will not be able to move the
door neither to receive any transmitter. Useful function to block the door during the night.
Adjust courtesy light activation time: The user can set the desired time to leave the cour-
tesy light at on simply bypressing a button on the cover.
New transmitters: The user can program new transmitters simply by pressing a button on the
cover (deleting transmitters is an action that is only allowed in installer mode).
ALARM device is
necessary to activ-
ate this function
Alarm function: With the ALARM accessory it is possible to detect unwanted openings of the
door (robbery), enabling the control panel’s sound alarm to be activated, or even connecting it
to the alarm system alreadypresent in the home.
With door totally closed, if someone tries to move it manually, the alarm will be activated.
To stop the alarm, press any button of a programmed transmitter.
jcmtechnologies
7

RadioSens3 System
RadioSens3 is an impact detection system installed at the last slat of the roller shutter. It detects the obstacle and reopens
without causing any damage.
The communication system between the RS3 T868 and the KEEroll is permanently monitored (two-way link via radio).
Options and sensibility selectors must be set before programming.
Any later change will have no effect.
Battery life
Table Battery life in days Manoeuvres / day
Manoeuvre time (s) 25 10 5 4
10 320 410 440 450
15 275 375 425 435
20 250 350 410 420
25 220 325 285 410
30 200 300 375 390
jcmtechnologies
8

RadioBand3 System
The RadioBand system is designed of domestic, commercial and industrial door applications where a safety edge is used. The
system provides a wireless system replacing spiral cables or energy chain systems to provide the safety signal to the door or
gate control panel. The receiver monitors the status of transmitters connected to it.
The transmitter is compatible with 8K2 monitored safety edges or electromechanical safety edges (NCcontact), and also with
standard lowvoltage optical safety edges and OSE-S7502B and OSE-S7502 optical safety edges.
The system complies with EN ISO13849-1:2015, category 2, PLd.
jcmtechnologies
9

KEEpad &KEEpush
KEEpad
3-channel motion transmitter; 3 different functions (open / close door, switch on courtesy light, activate KEEALARM...). Each
of these channels is activated with a different password.
KEEpush
3-channel motion transmitter; 3 different functions (open door, switch on courtesy light, ...)
jcmtechnologies
10

KEEalarm
KEEalarm monitors your door and prevents a thief from quietly forcing your garage door.
KEEalarm is an accessory that monitors for intrusions. If a thief triestoopen your door byforce, an acoustic alarm will be
triggered.
SESAME
SESAMEis the device for controlling the residential door with the mobile phone.
•Supports up to 10 different users (licences).
•Licences renewable every 5 years.
•Compatible with any router via Wi-Fi.
•Detection and resolution of issues through web.
•Compatible with Android 5.0 and iOS with the free JCM Honoa app.
SESAME features
•Check the status of the door in real time.
•Open and close the door from any location.
•Receive notifications everytime the door is open or closed.
•Safety devices low battery warning
jcmtechnologies
11

KEEroll
Installation
Control panel fixations
Remove the front cover of the control panel. Install the bottom part on the wall in a vertical position, at least 1,5 meters over
the ground and in accordance with the assembly instructions below.
jcmtechnologies
12

Connections
To prevent electric shocks, the equipment must be disconnected from the
power supply and all the electrical connections.
230VAC MONOPHASE MOTOR OUTPUTS
jcmtechnologies
13

OPTO SAFETY EDGE / 8k2 SAFETY EDGE INPUT (AUTOEDGE)
PHOTOCELL INPUT PUSHBUTTONS INPUTS
jcmtechnologies
14

Configuration / Starting up
Connect the power supply
Adjusting limit switch
Door MUST BE AT HALFWAY position before
starting the limit switch adjusting
Dipswitch 1 in ON. Door will move in dead man mode. Keep pressed or to move up
or down the door.
Press , to change the phase of the motor in case the door is not moving in the proper sense.
Dipswitch 1 in OFF to exit dead man mode.
Options selection
Dipswitch function OFF ON
1- DEADMAN Normal operation Dead man operation
2- AUTOCLOSE Do not close automatically Close automatically
3- PRE-FLASH Pre-flash disabled 3s pre-flash enabled
4- ALARM* (KEEalarm needed) Alarm function disabled Alarm function enabled
5- COURTESY LIGHT / ALARM Courtesy light output External alarm output
6- TEST PHOTO Test photocell disabled Test photocell enabled
* Optional alarm. JCM can provide you KEEalarm
jcmtechnologies
15

Set courtesy light
It is possible to define the activation time of the courtesy light.
To change the setting hold and release. Repeat this step until the desired setting is reached (see table).
You can only access settings with the door closed and the DIP 1 selector OFF.
Frontal light Activation time
1 flash Manoeuvre time + 1 minute
2 flashes Manoeuvre time + 5 minute
3 flashes Manoeuvre time + 10 minute
Fast flashes Manoeuvre time + 1 second
Programming
Transmitter programming
Press the key (you hear a beep and the key lights on) until you reach the necessary channel settings (see "Transmitter
programming" table for the different settings).
You can only access settings with the door closed and the DIP 1 selector OFF.
Front light Indication
1 flash Press the desired transmitter button to
activate open / stop / close
2 flashes Press the desired transmitter button to
activate the courtesy light
3 flashes Functionless
4 flashes Press the desired transmitter button to
activate the alarm (KEEalarm needed)
Fast continuous
flashes
Multichannel: attribute respectively each
button for each function
Press each transmitter button to be programmed, a beep will be heard each time a transmitter is programmed.
Press again to exit transmitter programming. The keylight will switch off.
jcmtechnologies
16

Manoeuvre programming
First program the safety elements (RadioSens3 or RadioBand3). Then program the maneuver.
Door MUST BE TOTALLY CLOSED before starting the manoeuvre programming.
Enter Installer mode: Press (KEEroll programming button), the maintenance indicator lights on, a beep will
be heard.
1- Press , with the door
totally closed, on cover and
the control panel will initiate
and auto- programming
sequence.
7- Autoclose time.
2- Door opens2 seconds. 8- Press on cover and door
closes.
3- Door closesautomatically. 9- Door stops.
4- Door stops. 10- Door opensautomatically.
*Only with RadioSens3
5- Door opensautomatically. 11- Door closesautomatically.
*Only with RadioSens3
6- Door stops. 12- Maintenance indicator
lights off. End programming.
By default, RadioSens3 system addsan inhibition zone of maximum 4cm at the end of the closing movement.
It is possible to change the inhibition zone pushing on when the door is closing (step 11). From this point, RadioSens3
will be inhibited.
STOP button aborts the programming sequence.
jcmtechnologies
17

Verification
Verify that the control panel is working properly
Once the control panel is correctly wired and programmed, check that all the system (accessories included) is working prop-
erly.
Transmitter
Press the transmitter button and check that the door opens. Press again, and check that the door stops/closes.
Photocell
Check that the LED is at OFF.
If the photocell is activated when the door's moving, the LED will pass at ON, indicating the activation of the photocell.
RadioSens3, RadioBand3 system or safety edge
Check that the LED is at OFF.
If the safety element is activated when the door'smoving, the LED will pass at ON, indicating the activation of the safety
edge.
Communication’s quality
To ensure that the radio communication is good enough, check that the LED is at OFF. If is permanently activated,
please check RadioSens3/RadioBand3.
jcmtechnologies
18

Maintenance
Enter Installer mode: Press (KEEroll programming button), the maintenance indicator lights on, a beep will
be heard.
The following functions can be done inside this maintenance mode.
Program maintenance manoeuvres
Maintenance warning: By entering Installer mode you can set the number of manoeuvres for the
maintenance warning.
Keep pressing to set up the maximum number of manoeuvres:
Frontal light Indication
1 flash 2.000 manoeuvres (default)
2 flashes 3.000 manoeuvres or one year
3 flashes 5.000 manoeuvres or one year
Reset manoeuvres counter
If the maximum number of movements is exceeded, the maintenance alarm lights on, by pressing there is
rapid blinking and the number of movements is adjusted to 0
Reset transmitters
Hold until and keysstarts flashing,
a beep will be heard. Without releasing , press to erase trans-
mitters, some beeps will be heard followed by a long beep.
jcmtechnologies
19

Reset safety elements
Hold until and keysstarts flashing,
a beep will be heard. Without releasing and press , to erase safety
elements, some beeps will be heard followed by a long beep.
In case of erasing safety elements, the manoeuvre has to be reprogrammed
again. See Programming chapter.
Fuse replacement
When you power supply the equipment, if the frontal panel does not light, remove the front cover and replace the fuse with
another fuse with the same characteristics. You have a fuse available on the middle cover for the first time.
jcmtechnologies
20
Other manuals for KEEROLL
3
Table of contents
Other JCM Technologies Remote Control manuals
Popular Remote Control manuals by other brands

Sanyo
Sanyo Moonlight RMT-U110 owner's manual

Siku
Siku SIKUCONTROL 6701 operating instructions

Empire Comfort Systems
Empire Comfort Systems EFRC installation guide

RCA
RCA RCRPS04GR Guía de inicio Rápido

Universal Remote Control
Universal Remote Control ONE FOR ALL 6200CMN manual

Samsung
Samsung MIM-E03*N installation manual