manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rane
  6. •
  7. Remote Control
  8. •
  9. Rane ZR1 User manual

Rane ZR1 User manual

This manual suits for next models

1

Other Rane Remote Control manuals

Rane DR3 User manual

Rane

Rane DR3 User manual

Rane DR1 User guide

Rane

Rane DR1 User guide

Rane DRZH User manual

Rane

Rane DRZH User manual

Rane VR2 Instruction Manual

Rane

Rane VR2 Instruction Manual

Rane DRZH User manual

Rane

Rane DRZH User manual

Rane DR2 User manual

Rane

Rane DR2 User manual

Rane IEEE 802.11a User manual

Rane

Rane IEEE 802.11a User manual

Rane CP R1 User manual

Rane

Rane CP R1 User manual

Popular Remote Control manuals by other brands

Bircher Reglomat RC Duo 2 user guide

Bircher Reglomat

Bircher Reglomat RC Duo 2 user guide

Emerson RCBT100 owner's manual

Emerson

Emerson RCBT100 owner's manual

BILDA Element-6 user manual

BILDA

BILDA Element-6 user manual

Absima CR7P manual

Absima

Absima CR7P manual

Mitsubishi Electric PAR-32MAAG Instruction book

Mitsubishi Electric

Mitsubishi Electric PAR-32MAAG Instruction book

RCA RCRTBL08BE1 quick start guide

RCA

RCA RCRTBL08BE1 quick start guide

US Electronics NOVARI user guide

US Electronics

US Electronics NOVARI user guide

Panasonic EUR7622KB0 Operation guide

Panasonic

Panasonic EUR7622KB0 Operation guide

Bang & Olufsen Beo4 user manual

Bang & Olufsen

Bang & Olufsen Beo4 user manual

Marantz RC101 user guide

Marantz

Marantz RC101 user guide

FUTABA 9ZAP - PART2 manual

FUTABA

FUTABA 9ZAP - PART2 manual

HR Matic HR MULTI 3 quick start guide

HR Matic

HR Matic HR MULTI 3 quick start guide

Anritsu MP1777A Operation manual

Anritsu

Anritsu MP1777A Operation manual

Niles WVC100 Installation & operating guide

Niles

Niles WVC100 Installation & operating guide

Bang & Olufsen BEO6 Getting started

Bang & Olufsen

Bang & Olufsen BEO6 Getting started

GE 94901 instruction manual

GE

GE 94901 instruction manual

FUTABA R7108SB Full manual

FUTABA

FUTABA R7108SB Full manual

Invacare G91S user manual

Invacare

Invacare G91S user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DATA SHEET / MANUAL ZR1 & PR2
COMMERCIAL PROCESSOR REMOTES
CP64S & CP52S CONNECTIONS
Turn the power to the CP unit OFF until all connections are made.
EUROBLOCK CONNECTIONS
When wiring to Euroblocks, a minimum wire gauge of 22 is pre-
ferred for reliability. If the ground or shield wire is left shorter,
it acts as a strain relief for the other wires. Cable with a exible
jacket is easier to use and less likely to damage the connections.
Avoid stripping excess insulation. Inspect wires for nicks that
may lead to wire breakage. Fully insert each wire in the appropri-
ate socket and tighten the screw.
REMOTE INSTALLATION
e CP64S supports wired remotes for Page Assign (PR2) and
Zone Level and Zone Source (ZR1) selection. e CP52S only
supports Zone Level and Zone Source (ZR1) selection. Wire
lengths of up to 1000 feet are possible. A brief list of suitable
wire types is provided below in the section on Wire Types.
e PR2 remote provides Page Zone Assign for Page 1 and
Page 2 signals and is usually located at the Page source. If your
application requires one of the two PAGE ASSIGN switches to
control both Page 1 and Page 2 Assign, simply wire Page 1 and
Page 2 control bits in parallel. You may wish to leave the knob
o the unused control and cover it with one of the hole plugs
provided in the kit. If your installation requires Page 1 and Page
2 remote control at two dierent locations, only three wires are
required for each PR2 remote (Z1, Z2 & GND). As above, you
may wish to leave the knob o the unused control and cover it
with a hole plug.
e ZR1 remote provides Zone Level and Source Selection,
allowing local control from inside the zone. Two ZR1 remotes
may be used (use only one for each Zone). If only one of the two
controls is used, you may cover the unused control with one of
the hole plugs provided in the kit. If you require one ZR1 remote
to control both Zones, simply wire the ports in parallel. is
may be done with selector only, volume only or both. If only one
of the two controls is wired in parallel, the other is still available
for a second remote.
When paralleling one remote across multiple CP64Ss, all
three control pins must be wired, including the shields.
Power to the CP64S or CP52S should be o until all connec-
tions are made. It is important to ensure that the Remote Ports
are not subjected to sustained voltages outside the range of 0 to
5 volts DC or high levels of static. Inputs are protected, howev-
er, caution is the better part of... you know. It is a good idea to
install the wiring, connect it to the remote assemblies and then
make the nal connections at the CP unit. Do not short Vr1 or
Vr2 pins to ground. ese pins are current limited, however, ex-
cess heat is generated in the 5 volt supply if a short occurs. Never
subject the Vr1 or Vr2 pins to voltages above 5 volts.
REMOTE MOUNTING
e ZR1 and PR2 remote assemblies mount in a standard U.S.
electrical box with a minimum depth of 2.25" (5.5 cm). Be sure
to note the wire color of each input in order to facilitate correct
wiring to the CP unit. Connect each wire to the 5-pin connec-
tor by fully inserting it in the correct socket and tightening the
screw. Make sure wires are free of nicks and that the cable jacket
is stripped back suciently to allow it to lie in the electrical box
with the remote assembly inserted. Use the at head #6 screws
supplied with the kit to mount the remote assembly and silk-
screened front panel to the electrical box (see above diagram).
Note the “UP” arrow screened on the printed circuit board of
each remote (mount it pointing up).
Install each knob so that the line on the knob is properly
aligned with the silk-screening on the front panel of the remote
assembly. Install any Decora plate of your choice. For a secured
installation, you may wish to leave the knobs o and use a blank
Decora plate to cover the remote after adjustment.
PROGRAM SELECT
LEVEL
82
100
46
L1
L3L2
P
PAGE 2 ASSIGN
PAGE 1 ASSIGN
BOTHOFF
BOTH
Z1
OFF
Z2
Z1 Z2
All features & specications subject to change without notice. 10013
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 TEL 425-355-6000 FAX 425-347-7757 WEB rane.com
1
2
3
4
5
S2A
6
7
8
9
10
S2B
2
3
4
1
5
J1A
5 POS TERM
GND
GND
6
7
8
9
10
S1B
1
2
3
4
5
S1A
GND
GND
GND
Z2
Z1
GND
Z1
Z2
PAGE 1
PAGE 2
PAGE REMOTE (PR 2)
1
2
3
4
5
S1A
6
7
8
9
10
S1B
2
3
4
1
5
J1A
5 POS TERM
GND
GND
GND
D1
D0
Vc
Vr
ZONE REMOTE (ZR 1)
CW
2
1 3
R1
2KRD
WIRE TYPES
Variations in wire type do not greatly aect the performance
of the remote controls. However, 22-gauge stranded wire with
a exible jacket is recommended. You may use 5-conductor
unshielded remote control signal cable for shorter runs (less than
200 ft.) or 4-conductor (2 pair) shielded remote control signal
cable (use the shield as the GND return) for longer runs (200 to
1000 ft.). e type of wire required is inuenced by your instal-
lation and local electrical codes.
Rane Corporation does not provide or source cable. Please
contact your local retail or wholesale outlet, not the factory. e
following is a short list of suitable cable types:
CONSOLIDATED ELECTRONIC WIRE AND CABLE
Plenum cable:
Unshielded remote control signal cable CAT. # 9896
Shielded remote control signal cable CAT. #9877, CAT. #9852
WEICO WIRE & CABLE INC.
Communication and control cable:
Multiconductor, unshielded CAT. #7606
ALPHA
Communication and control cable:
Multiconductor, unshielded CAT. #1175C
BELDEN
Unshielded remote control signal cable CAT. # 88741
Shielded remote control signal cable CAT. # 88723