Introduction
The system is designed for applications where pedestrian doors installed on garage doors. Is a position detection system of
the pedestrian door status, so that if it is open the system prevents the start of the movement of the garage door.
Is a wireless system composed by one transmitter and one receiver. The receiver monitors the status of transmitters connected to it.
The system complies with EN ISO 13849-1, category 2, PLc.
Technical data
Frequency
869,50 MHz
Power supply
12/24V ac/dc (9-35V dc / 8-28V ac)
Consumption standby/operating
18mA/80mA
Memory
6 transmitters (3 on relay 1, 3 on relay 2)
Relay numbers
2 relays
Relay contacts
1A
Radiated power
< 1mW
Operating temperature
-20ºC - +85ºC
Seal
IP54 (with IP65 cable glands)
Box size
82 x 190 x 40mm
Range
50m
Starting up
Mechanical installation
Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid metal
surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver. Connect the power cables to
the terminals of the printed circuit, following the indications of the connections diagram. Store the transmitter on the receiver. Fix
the front of the receiver to the back with the screws supplied for the purpose.
Programming the transmitter on the receiver
While programming the receiver, press the PROG button on the transmitter to be programmed into the receiver.
The receiver allows programming 6 transmitters (3 for Relay 1 and 3 for Relay 2).
Each safety edge transmitter must be learnt into the appropriate channel of the safety edge receiver.

3200369_RCONTACT-R_EN_Rev02 Page 2/3
Mode
Configuration of transmitter programming in the receiver.
Led R1
Led R2
1
When you open the pedestrian door, relay 1 on the receiver will be activated
ON
OFF
2
When you open the pedestrian door, relay 2 on the receiver will be activated
OFF
ON
3
When you open the pedestrian door, the two relays will be activated at the same time
ON
ON
PRESS RPORG BUTTON LED TURNS ON PRESS TRANSMITTER PROG ONE BEEP & PROGRAMMED
PRESS RPROG BUTTON LED TURNS OFF & END PROG
Autotest signal
Check the autotest output on the control panel, in stanby, to see whether the voltage is 0V (positive polarization) or 12/24V ac/dc
(inverted test input). Switch on the autotest signal of the panel and check that it has a maximum duration of 3 seconds.
Autotest output
in standby
Autotest output
activated
Polarization type
Jumper
ATEST POL
ATEST1
ATEST2
Connection to a equipment with
autotest
0V
12/24V
Positive
OFF
Connected*
Connected*
12/24V
0V
Inverted
ON
Connected*
Connected*
Connection to a equipment without
autotest **
---
---
---
OFF
Not connected
Not connected
* Nota: Connect autotest only for used outputs.
** Where the autotest is not used, the system is not checked at the start of the operation, which means that security standard EN 12453 regarding the use of motorised
garage doors is, in some cases, not complied with..
Maintenance
Beeps and leds messages / errors indication table
B1/B2
Led
Check
Led
Beeps
Equipment
Message / error
Solution
ON
OFF
No beeps
RCONTACT R
Detection of pedestrian door at open state
---
RCONTACT transmitter not programmed
Verify if it must be programmed and perform the
programming.
Communication failure between RCONTACT R
and RCONTACT T
Verify the batteries of the emitter and if they are
charged, verify the radio signal with the Check
function.
OFF
OFF
4 beeps each
20 seconds
RCONTACT R
RCONTACT/T low battery
Verify the batteries of the transmitter
OFF
ON
No beeps
RCONTACT R
Check function. See coverage and signal quality
table.
---
System Check
This function has to be used to check the operation and range of all the devices once the installation has been carried out.
Press the receiver’s CHECK button for at least 1 second to enter check mode. The indicator light will come on and four beeps will be
heard.
Perform a complete door opening and closing manoeuvre. During the system check a beep will be heard every 1,5 seconds.

3200369_RCONTACT-R_EN_Rev02 Page 3/3
CORRECT OPERATION OF THE SYSTEM
If no other acoustic signal is heard on completing the manoeuvre, the system is operating correctly. Either press the CHECK
button again or wait 5 minutes and the receiver will exit checking automatically, indicating with two beeps that the check
has been correct. The check indicator light will go out.
DETECTION OF TRANSMISSION FAILURE
If the communication with a transmitter fails during checking, or the communication is deficient (for instance, too many
communication retries or poor coverage), the receiver emits three consecutive beeps, indicating that an error has occurred.
Halt the door manoeuvre and open the pedestrian door to detect what has failed.
-If a single beep is heard on opening the pedestrian door, this means that the safety edge is correct.
-If three consecutive beeps are heard on opening the pedestrian door, this means that the safety edge has failed.
In this event, it is recommended changing the orientation of the transmitting-receiving aerials or installing an AED-
868 or FLAT-868 outdoor aerial to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator light will flash continuously.
Perform another system check until the result is correct.
Signal coverage
After opening the pedestrian door, continuous flashes, ranging from 1 to 5, indicate the signal coverage for the transmitter
at the time it was detected.
Number of check LED flashes
Coverage
Result of check
1
Very weak
Safety edge failure
2
Weak
OK
3
Normal
OK
4
Good
OK
5
Very good
OK
Total reset
In programming mode, keep the programming PROG button pressed down and make a bridge with the “MR” reset jumper for 3s.
The receiver will emit 10 warning sound signals and then more at a faster frequency, indicating that the operation has been carried
out. The receiver will stay in programming mode.
If 10 seconds pass without programming a transmitter, the receiver will exit the programming mode, emitting two 1 sec beeps.
Replacing a transmitter
If a transmitter becomes damaged the whole system must be reset and replaced, and non-damaged transmitters must then be re-
programmed into the receiver.
Use of the system
This equipment is designed for applications where pedestrian doors installed on garage doors. It is not guaranteed for
directly activating equipment other than that specified.
The manufacturer reserves the right to change the specification of the equipment without prior warning.
Important annex
Disconnect the power supply whenever you proceed to the installation or repair of the control panel.
In accordance with the European low voltage directive, you are informed of the following requirements:
-For permanently connected equipment, an easily accessible connection device must be incorporated into the cabling.
-This system must only be installed by a qualified person that has experience with automatic doors/gates and knowledge of the
relevant EU standards.
-The instructions for use of this equipment must always remain in the possession of the user.
-The frequency of the RContact system does not interfere in any way with the 868 MHz remote control systems.
JCM TECHNOLOGIES, S.A. declares herewith that the product RCONTACT R complies with the relevant fundamental
requirements of the RED Directive 2014/53/EU, as well as with the Machine Directive 2006/42/EC whenever its usage
is foreseen; and with the 2011/65/EU RoHS Directive.
EC Declaration of conformity
See web www.jcm-tech.com
JCM TECHNOLOGIES, SA · BISBE MORGADES, 46 BAIXOS - 08500 VIC (BARCELONA) SPAIN
Table of contents
Other JCM Technologies Transmitter manuals
Popular Transmitter manuals by other brands

MODSTER
MODSTER Vector SR48 user manual

Endress+Hauser
Endress+Hauser Cerabar M operating instructions

Novatech
Novatech 1730 Series Reference manual

Advanced Microwave Products
Advanced Microwave Products VHT1 quick start guide

Krone
Krone OPTISOUND 3030 C Handbook

Labom
Labom CG201x series operating instructions

MK
MK K5786 Installation & operating instructions

Tricor
Tricor TCE-8000 Programming guide

Pyramid
Pyramid TIMETRA SYNC RF 9T1WI installation instructions

Walkera
Walkera 2402D user manual

Lectrosonics
Lectrosonics UT195 Operating instructions and troubleshooting guide

Emerson
Emerson Micro Motion 5700 Configuration and Use Manual