manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. John Guest
  6. •
  7. Plumbing Product
  8. •
  9. John Guest Speedfit KM39767 User manual

John Guest Speedfit KM39767 User manual

This manual suits for next models

2

Popular Plumbing Product manuals by other brands

Moen SANI-STREAM 8797 manual

Moen

Moen SANI-STREAM 8797 manual

Grohe Allure Brilliant 19 784 manual

Grohe

Grohe Allure Brilliant 19 784 manual

Cistermiser Easyflush EVO 1.5 manual

Cistermiser

Cistermiser Easyflush EVO 1.5 manual

Kohler Triton Rite-Temp K-T6910-2A installation guide

Kohler

Kohler Triton Rite-Temp K-T6910-2A installation guide

BEMIS FNOTAB100 Installation instruction

BEMIS

BEMIS FNOTAB100 Installation instruction

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Akw Stone Wash Basin Installation instructions manual

Akw

Akw Stone Wash Basin Installation instructions manual

Enlighten Sauna Rustic-4 user manual

Enlighten Sauna

Enlighten Sauna Rustic-4 user manual

Moen ShowHouse S244 Series quick start guide

Moen

Moen ShowHouse S244 Series quick start guide

Sanela SLWN 08 Mounting instructions

Sanela

Sanela SLWN 08 Mounting instructions

Franke 7612982239618 operating instructions

Franke

Franke 7612982239618 operating instructions

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Heritage Bathrooms

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Tres TOUCH-TRES 1.61.445 instructions

Tres

Tres TOUCH-TRES 1.61.445 instructions

STIEBEL ELTRON WS-1 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON WS-1 Operation and installation

Miomare HG00383A manual

Miomare

Miomare HG00383A manual

BELLOSTA revivre 6521/CR1 quick start guide

BELLOSTA

BELLOSTA revivre 6521/CR1 quick start guide

American Standard Heritage Amarilis 7298.229 parts list

American Standard

American Standard Heritage Amarilis 7298.229 parts list

BorMann Elite BTW5024 quick start guide

BorMann

BorMann Elite BTW5024 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The company has a policy of continuous research
and development and reserves the right to amend
without notice the specification and design of all
products illustrated in this catalogue. John Guest
Speedfit reserve the right to change the colour and
shape of products. Photographs are for illustration
purposes only.
Subject to our Terms and Conditions
of Sale available on request.
Z2105/217/10/07
No.’s 95/3177 BS7291
KM39767
AVAILABLE FROM:
THE PUSH-F T SOLUT ON FOR
PLUMB NG & HEAT NG SYSTEMS
UK PRODUCT RANGE AND
NSTALLAT ON GU DE
October 2007
, and are
registered
trademarks of John Guest International
Limited
© Copyright 2007.
C /SfB
53.0 h6
John Guest Speedfit Limited
Horton Road, West Drayton, Middlesex UB7 8JL, England.
Tel: 01895 449233 Fax: 01895 420321. www.speedfit.co.uk
Technical Help Desk: 01895 425333
THE PUSH-F T SOLUT ON FOR
PLUMB NG AND HEAT NG SYSTEMS
JG Speedfit is a push-fit system suitable for the plumbing
of normal domestic hot and cold water services and
central heating applications, including pressurised and
combi systems.
Speedfit Fittings have been designed for use with both
Speedfit and copper pipe.
Extensive tests have shown that Speedfit products will
withstand temperatures and pressures well in excess of
normal working conditions.
JG Speedfit should be installed to conform with good
plumbing practice.
British Gas Service has accepted the John Guest Speedfit
System as being suitable for open vented and sealed
central heating systems and as eligible for acceptance
onto its service contracts.
Performance specifications are well within those required
for most normal domestic central heating and water
supply systems including:
•Mains fed and indirect cold water systems
•Vented and unvented hot water systems
•Vented central heating systems
•Sealed central heating systems provided
temperatures and pressures comply with
BS7291 Parts 1, 2 and 3 Class S.
•Underfloor heating
Speedfit EX Fittings
and Barrier ipe.
K24076, K24077 and K24078
British Gas
Service
BS7291
No. KM39767
Worldwide connections
The John Guest Group has a long
established reputation as a world leading
manufacturer of push-in fittings, tube and
other fluid control products. A
reputation built on producing consistently
high quality products with an ongoing
commitment to value engineering and
product development.
01 02
Technical Support
Our national team of Technical Support Engineers is
available to help you get the best from your
S
S
p
p
e
e
e
e
d
d
f
f
i
i
t
t
System. This includes a free underfloor heating estimate
and CAD design service.
T
Te
ec
ch
hn
ni
ic
ca
al
l
H
He
el
lp
p
D
De
es
sk
k:
:
0
01
18
89
95
5-
-4
42
25
53
33
33
3
The J
JG
G
S
S
p
p
e
e
e
e
d
d
f
f
i
i
t
t
Technical Advisory Service is available
to assist and advise on the aspects of the
S
S
p
p
e
e
e
e
d
d
f
f
i
i
t
t
System. The service is available 8:00am to 5:00pm
Monday to Friday.
The System is approved by the BRA and the WRAS.
Speedfit ‘PEM’ fittings and PEX and Polybutylene Barrier
Pipe are Kitemarked to BS7291 Parts 1, 2 and 3 Class S
Licence No KM39767.
Q ality Man fact re
A commitment to quality is at the heart of the John Guest Philosophy.
The strictest control is maintained by virtue of the fact that design and manufacture is carried
out in modern purpose built manufacturing centres in west London and at Maidenhead in
Berkshire.
Maintaining control over the whole process from initial tool design and tool making through
to final assembly and testing ensuring that only products of the highest quality are produced.
The company believe it is this commitment to quality that has led to it receiving prestigious
awards from many of the world’s leading testing and approvals organisations.
John Guest is a preferred supplier to many international companies.
•nstallation time reduced by up to 40%
•Pipe flexibility permits the cabling of pipe through less
accessible areas
•No risk of fire or flames from a blowtorch
•Easier to work in confined places
•A permanent leak-proof connection
•Corrosion free
•No scale build up
•Lower thermal diffusivity maintains safer surface
temperature
•Pipe elasticity can reduce the possibility of bursting
under freezing conditions
•Lead free and non toxic
•Less noise from water flow and expansion/contraction
•Long pipe lengths reduce fittings required
SYSTEM FEATURES
•All white system
•Truly demountable without damage to pipe or fitting
•Grip and seal connection
•Superseal nsert gives secondary seal
•Reduced pipe insertion force
•Lightweight and easy to handle on site
SYSTEM BENEF TS
As a result of long term test programmes and rigorous
quality standards, John Guest Speedfit Limited offer a 25
year guarantee against the defects in materials or
manufacturing of ‘PEM’, ‘PSE’ and ‘SFM’ Range
Plumbing Fittings and Speedfit Barrier Pipe
manufactured by John Guest.
John Guest Underfloor Heating Products, which should
be installed and maintained in accordance with our
recommendations, carry a 2 year guarantee against
defects in materials and manufacture.
John Guest Plumbing and Heating Products are for use
with normal UK domestic plumbing and heating systems
and supplied in accordance with our Conditions of Sale.
GUARANTEE
Boats. The flexibility of the Speedfit System ensures it can
be cabled easily around the interior and hidden from view.
Caravans. Speedfit is ideal for caravan installations due
to its flexibility and its resistance to corrosion and freezing.
Exhibitions. The unique ability of the Speedfit System to
be easily demounted and reused, together with its
flexibility, makes Speedfit ideal for this application.
Agric lt ral and Hortic lt ral.
Speedfit has many
applications in agricultural and horticultural environments.
Portable B ildings (site cabins, toilets). As with caravans,
Speedfit is well suited to this application.
Speedfit fittings suitable for central heating systems can
withstand temperatures up to 114°C intermittently for
short periods.
Speedfit fittings shown as not suitable for central heating
systems are used primarily on the domestic hot and cold
water system accepting temperatures of up to 65°C.
Ensure fittings and pipe are kept clean at all times by
keeping them in bags and boxes provided.
Do not empty Speedfit Products onto the floor area.
Ensure internal ‘O’ Ring seals are kept free from dirt and debris.
John Guest fittings and related products are specifically
designed and manufactured by John Guest to the
Technical Specifications set out in the John Guest
Product Catalogues. All John Guest fittings and related
products should be selected, installed, used and
maintained in accordance with these Technical
Specifications. t is the customer’s / user’s responsibility
to ensure that John Guest fittings and related products
are suitable for their intended applications, are properly
installed and maintained and are used in accordance with
the Technical Specifications. t is also the customer’s /
user’s responsibility to provide it’s own customers with
any relevant technical information about John Guest
products it supplies them.
Speedfit should not be used for gas, fuel oil or compressed
air applications.
John Guest produce a push fit system of pipe and fittings
for
compressed air situations. See seperate literature for details.
SPEC AL APPL CAT ONS
WORK NG TEMPERATURES AND PRESSURES
HANDL NG F TT NGS AND P PE
PRODUCT SELECT ON AND NSTALLAT ON
03 04
Contents
PLUMB NG AND HEAT NG
UNDERFLOOR HEAT NG
UNDERGROUND F TT NGS
TECHN CAL CHECKL STS
Plumbing and 09 - 10
Heating Fittings
Flexi Hoses 11 - 12
Brass Fittings 12
Valves 13
Pipe and 14 - 15
Accessories
22 - 26
27 - 28
Designed to be quick and easy to install.
For connecting MDPE
Cold Water Service Pipe.
Plumbing and Heating 29
Underfloor Heating 30
Underground Fittings 30
Application Usual Working Maximum working Maximum working
temperature, ºC temperature, ºC pressure, bar
Cold Water 20 20 12
(indirect and direct mains)
Central Heating 82 105, short term 3
malfunction at 114
Hot Water 65 95 6
(including unvented cylinders)
HOW SPEEDF T WORKS
Grips before it seals
Main ʻOʼ Ring Seal
Stainless steel teeth
grip the pipe
Pipe insert gives
secondary seal
Speedfit Fittings have a unique grip then seal construction made up of a collet with stainless
steel teeth to grip the pipe and an ‘O’ ring to provide a permanent leak proof seal.
Use of the Superseal Pipe nsert ensures a double ‘O’ ring seal.
An ‘O’ ring at the head of the insert and the shape of the stem, provide a secondary seal against
the bore of the fitting. A combination of this and the main ‘O’ ring ensure a good connection.
The stem of the insert gives greater rigidity of the length of pipe within the fitting, reducing the
chance of leaks if a side load is applied.
The head of the insert has been designed for ease of insertion.
The additional benefit of Twist and Lock Fittings is that a twist of a screwcap locks the pipe in
position and gives increased compression on the ‘O’ ring for even greater security.
MAK NG A GOOD CONNECT ON
Pipe Cutter
JG TS
Speedfit
Barrier Pipe
Ensure the pipe is free of score
marks. Cut the pipe square.
When using Speedfit Barrier Pipe
cut along an insertion mark. We
recommend the use of JG Pipe
Cutters.
To prevent damage to the ‘O’ ring
remove all burrs and sharp edges.
When connecting Speedfit Pipe
use a Superseal Pipe nsert. A
twisting motion will aid insertion.
The insert should only be used
with Speedfit Pipe.
Fittings and pipe should be kept clean bagged and undamaged
before use.
NEW TW ST AND LOCK F TT NGS
The fitting should be in the ‘unlocked’ position, this is
shown with a small gap between the screwcap and the
body flange.
Push the pipe fully into the fitting, up to the pipe stop. f
the Speedfit Pipe has been cut correctly the insertion
mark on the pipe will be level with the collet head. The ‘O’
ring on the Superseal Pipe nsert provides a secondary
seal against the bore of the fitting. A good connection
has been made.
Gap between Cap
and Flange
Pipe mark indicates
full insertion
Twist the screwcap until it
touches the body flange.
This increases the ‘O’ ring
seal around the pipe and
locks the pipe into position.
f you are not using collet
clips, ensure that the
screwcaps are in the
locked position.
Pull to check it is secure. t is good practice to test the system
prior to leaving the site or before use. Our recommended
test procedure is shown in our Technical Checklist.
ADDED BENEF T TW ST AND LOCK
STANDARD SPEEDF T F TT NGS
Standard Speedfit connections are made in the same way
as Twist and Lock.
Push Pipe up to Pipe Stop. f the Speedfit Pipe has been
cut correctly the insertion mark on the pipe will be level
with the collet head.
Push pipe up to stop
Secondary Seal
Pipe mark indicates
full insertion.
Pull to check connection
is secure and test the
system. Our recommended
test procedure is shown
in our Technical Checklist
on page 29.
TO D SCONNECT
Ensure that the system
is depressurised.
The screwcap on Twist
and Lock Fittings will
need to be turned back
to the unlocked position.
WHAT NOT TO DO
Fitting may be gripped but not
sealed if pipe is not fully inserted.
Don’t use hacksaws to cut the
pipe or leave burrs on the end of
the pipe.
Do not insert fingers into the fitting as the stainless steel
teeth may cause injury.
Remember to pressure test the completed installation
according to the recommendations in our Technical Checklist.
✗
✗
Don’t use
damaged or
scored pipe.
✗
PREPARE THE P PE
05 06
Push the collet square against the face of the fitting by
using fingers or with the help of our collet release tool.
With the collet held in position the pipe can be removed.
The fitting can be used again without the need for
replacement parts.
Don’t forget to push the
pipe fully into the fitting,
past both the collet (gripper)
and the ‘O’ ring.
Use a collet cover or collet clip to provide added security
against pipe disconnection, e.g. the fitting coming into
contact with rigid surfaces and behind dry-lining walls.
Collet covers for use with standard Speedfit fittings, are
available in white or in red or blue to allow colour coding of pipes.
Stops are located at the following distances from the end
of the fitting:
size 10mm 15mm 22mm 28mm
stop distance 20mm 30mm 35mm 44mm
Collet cover
Collet clips are available in grey and white for use with
standard fittings to prevent accidental pipe
disconnection.
Red or blue collet clips provide colour coding of pipe on
twist and lock fittings.
They are not designed to prevent accidental release and
should be fitted when the fitting is in the locked position.
Collet clip
The action of pressure in a system could increase the grip
of the collet. The release aid allows a firmer grip on the
collet whilst removing the pipe.
Release aid
P PE STOP D STANCES
COLLET COVERS
RELEASE A D
COLLET CL PS
The unique feature of the
Speedfit Concept, the ability
to disconnect the fitting
should you want to, means
the Speedfit Stop End not
only provides a permanent
leakproof seal, but can be
readily removed to allow
work to restart or to allow
an extension to a system.
Thus, the fitting is especially
useful to allow water to be
turned back on, overnight for
instance, or if a job has to be
interrupted for another reason.
Stop end
Stop ends are also useful when pressure testing a system
before appliances are connected.
Designed to simplify pipe connection
in restricted spaces. The Speedfit
Stem Elbow provides an instant swivel
fitting so pipe can be orientated in
any direction.
A special 10mm version gives a neat
connection from concealed plumbing
to
a radiator.
STOP END
STEM ELBOW
The Speedfit range of brass
chromium plated service
valves can be used on both
hot and cold water services
and central heating. Push fit
connections mean much
reduced installation time,
especially in confined spaces.
The valves, in 10 to 22mm,
have a 1/4 turn open/close
mechanism operated by a
screwdriver slot or a lever.
Tap connector patterns have
a union nut to connect
direct to a tap or floatvalve.
Lever
operated valves are
supplied
with both a blue
and a red indice.
The ability of Speedfit products
to twist whilst in situ
allows
the screwdriver slot
operating valve to be turned
out of sight,
helping to avoid
unauthorised tampering.
Speedfit x Speedfit
Mechanism twists out of sight
SERV CE VALVE
Speedfit manufacturer a wide range of connectors
including conventional straight and bent tap connectors.
The range also offers a special and
unique Tap Connector that only
requires a simple hand tightening to
connect up a terminal tap, mixer or
float valve. An integral seal within the
fitting avoids the need for further
sealant. The connectors are useful
when replacing existing brassware or
in other confined spaces.
Coupling up to a supply is easy. The
pipe is simply pushed home into
the Speedfit connection and is
instantly secured, without the need
for specialist tools.
TAP CONNECTORS
Speedfit have introduced an innovative 22mm x 10mm 4
way manifold. Departing from the usual manifold design,
this new product has 4 in-line 10mm outlets, offering a
neater envelope size and therefore a much smaller
installation space.
Other benefits include better flow characteristics and a
more even distribution of hot water.
The 22mm and 10mm Speedfit push-fit connections make
for a fast and easy installation, even in confined spaces.
Whilst designed as a heating product, the manifold can
also be used in a mains pressure hot or cold domestic
plumbing system, to feed bathroom or kitchen taps and
mixers. This allows for a more efficient installation as
every terminal fitting has its own dedicated supply.
SPEEDF T MAN FOLD
The Speedfit range includes an Appliance Tap for
the permanent connection of washing machines and
dishwashers, thus enabling complete water isolation to
the appliance.
A simple push fit connection of the supply pipe and a
plastic thread on the outlet to marry well with the plastic
thread on the hose means the Speedfit Appliance Tap is very
easy to install. The large round handle is easy to grip and turn.
APPL ANCE TAP
The Speedfit Connection, when made with the insert, has
a number of design features.
Sliding the stem of the insert into the pipe gives greater
compression of the main ‘O’ ring on the pipe and greater
rigidity of the length of pipe within the fitting, reducing the
chance of leaks if a side load is applied.
A connection is easier to make because the head of the
insert has been designed for ease of insertion.
Superseal nserts are listed on page 14.
SUPERSEAL P PE NSERT
07 08
Manufactured to a quality you would expect from Speedfit,
our range of Flexi Hoses has 40 different patterns.
Available in lengths from 150mm to 1,000mm, ends are
either push fit to union nut or push fit to push fit,
including
hoses with an integral
service valve operated by a 1/4 turn
screwdriver slot.
Apart from being aesthetically
pleasing the new white
hoses offer more flexibility and a larger through bore
for better flow characteristics.
More specialist patterns
have been designed to help
the installation of monobloc
mixers to a 15mm supply.
Sold in pairs, each hose in
the pair has a different
spanner location to ease
connection of the threaded
end into the monobloc’s
inlets.
The hoses are suitable for cold water up to 10 Bar and
hot water (65˚C max) up to 6 Bar and approved by WRAS.
The Superseal Pipe nsert has been developed to be used
with Speedfit Barrier Pipe and Speedfit Fittings to provide
an extra line of defence when installing a Speedfit Push
Fit System.
The insert has it’s own ‘O’ ring which, with a stem sliding
within the inside of the pipe, gives a secondary seal
against the inside of the fitting.
FLEX HOSES
PLUMB NG F TT NGS
ART NO. SIZE MM
ART NO.SIZE MM
Suitable for central heating systems.
ART NO.SIZE MM
PEM0410W 10
PEM0415W 15
PEM0422W 22
PEM0428W 28
Suitable for central heating systems.
PEM201510W 15 x 10
PEM202215W 22 x 15
Suitable for central heating systems.
ART NO.SIZE MM
JG601B 20 x 15
JG603B 25 x 15
JG602B 25 x 22
Cold water only.
Used to connect PE Pipe to Speedfit
or to Table X or Y Copper.
Taken from the Speedfit Underground Fittings
Range, see separate section for details and
Technical Specification.
PEM0310W 10
PEM0315W 15
PEM0322W 22
PEM0328W 28
EQUAL STRA GHT CONNECTOR
ART NO. I E STEM
PEM221010W 10 x 10
PEM221015W 10 x 15
PEM221515W 15 x 15
PEM222222W 22 x 22
ART NO.SIZE MM
PEM0210W 10
PEM0215W 15
PEM0222W 22
PEM0228W 28
Suitable for central heating systems
Please note a Collet Cover cannot be used
on a Speedfit end assembled with the stem
of a 22mm Stem Elbow.
Suitable for central heating systems.
ART NO.SIZE MM
PEM3015BW 15 x 10 x 10
PEM3015AW 15 x 15 x 10
PEM3022CW 15 x 15 x 22
PEM3022BW 22 x 15 x 15
PEM3022DW 22 x 15 x 22
PEM302210AW 22 x 22 x 10
PEM3022AW 22 x 22 x 15
PEM3028BW 28 x 22 x 22
PEM302815AW 28 x 22 x 28
PEM3028AW 28 x 28 x 15
PEM3028DW 28 x 28 x 22
Sizes are listed in the following order.
Suitable for central heating systems.
12
3
Provides a swivel
type connection.
ART NO.SIZE
Suitable for central heating systems.
For torque figures see Technical Checklist.
ART NO. SIZE
PSE3210W 10mm x 1/2” BSP
PSE3201W 15mm x 1/2” BSP
PSE3203W 15mm x 3/4” BSP
PSE3202W 22mm x 3/4” BSP
Suitable for central heating systems
Note: Plastic threads are not as strong
as metal threads.
For torque figures see Technical Checklist.
Requires hand tightening only.
With brass swivel nut and sealing washer.
ART NO.SIZE
Suitable for central heating systems.
For torque figures see Technical Checklist.
ART NO.SIZE MM
ART NO.SIZE MM
PL10 10
PL15 15
PL22 22
PL28 28
Suitable for central heating systems.
PEM061510W 15 x 10
PEM062215W 22 x 15
PEM062815W 28 x 15
PEM062822W 28 x 22
PEMSTC1514 15mm x 1/2” BSP
PEMSTC1516 15mm x 3/4” BSP
PEMSTC2216 22mm x 3/4” BSP
PEMBTC1514 15mm x 1/2” BSP
ART NO.SIZE MM
PSE4610W 10
PSE4615W 15
PSE4622W 22
Suitable for central heating systems.
ART NO. SIZE MM
CM0715S 15
CM0722S 22
CM0728S 28
Suitable for cold water tanks only.
Requires hand tightening only.
Maximum wall thickness of tank 4mm.
Suitable for central heating systems.
With brass swivel nut and sealing washer.
REDUC NG STRA GHT COUPLER
PE-COPPER COUPLER
EQUAL ELBOW
STEM ELBOW
EQUAL TEE
REDUC NG TEE
TANK CONNECTOR
STOP END
REDUCER
FEMALE COUPLER - TAP CONNECTOR
STRA GHT TAP CONNECTOR
BENT TAP CONNECTOR
PLUG
09 10
ART NO.SIZE MM
PEM532210W 22 x 22 x 10
PEM532215W 22 x 22 x 15
Sizes are listed in the following order.
Suitable for central heating systems.
12
3
STEM TEE
ART NO.SIZE
NC471 1/2 id x 15mm
NC2324 3/4 id x 22mm
Suitable for central heating systems.
Connects imperial to metric pipe.
ART NO.SIZE MM
CM-SC-15S 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.SIZE
NC448 15mm x 1/2"
NC473 22mm x 3/4"
NC737 22mm x 1/2"
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.
JG- ROP
Creates a neat outlet for 10mm supply pipes to a radiator. To be
used with single gang 25mm steel K0 boxes to BS 4662, fitted
with rubber grommet.
CONVERS ON CONNECTOR
SL P CONNECTOR
HOSE CONNECTOR
RAD ATOR OUTLET PLATE
ART NO.SIZE
MM
JGRA L4 4 Zone 22 x 15
JGRA L6 6 Zone 22 x 15
JGRA L12 12 Zone 22 x 15
BRASS RA L MAN FOLD
ART NO.SIZE MM
SFM512210S 22 x 10
Suitable for central heating systems.
4 WAY MAN FOLD
ART NO.SIZE MM
SFM522210S 22 x 10
SFM522215S 22 x 15
Suitable for central heating systems.
4 PORT RA L MAN FOLD
ART NO.SIZE
MM
JGMAN2-R 2 Port 3/4” x 15
JGMAN3-R 3 Port 3/4” x 15
JGMAN4-R 4 Port 3/4” x 15
JGMAN2-B 2 Port 3/4” x 15
JGMAN3-B 3 Port 3/4” x 15
JGMAN4-B 4 Port 3/4” x 15
BRASS MAN FOLD
Red Handle
Blue Handle
Blanking plug supplied
with each manifold.
Control knobs have the means to be labelled
ʻBasinʼ, ʻBathʼ, ʻSinkʼ, ʻShowerʼ, ʻToiletʼ, ʻBidetʼ
or ʻWashing Machineʼ.
ART NO. SIZE
MM X BS
Hot and cold water only, maximum 65
º
c.
Protect from sunlight and frost.
PLAST C BACK PLATE ELBOW
15PWB 15 x 1/2"
MAN FOLDS
FLX43P 15 x 1/2"
FLX34P 10 x 1/2"
FLX35P 15 x 3/8"
FLX15P 15 x 1/2"
FLX16P 15 x 3/4"
FLX22P 22 x 3/4"
FLX18P 15 x 1/2"
FLX20P 15 x 3/4"
FLX19P 22 x 3/4"
FLX23
Full Bore
22 x 3/4"
FLX40 15 x 1/2"
FLX42 15 x 3/4"
FLX41 22 x 3/4"
Not suitable for central heating systems.
Hot and Cold water only, 65°C max.
500mm long
300mm long
ART NO.SIZE MM
FLX33P 15 x 10
FLX17P 15 x 15
FLX26P 22 x 22
FLX21P 15 x 15
FLX27P 22 x 22
FLX47 15 x 15
300mm long
500mm long
BRA DED FLEX HOSES
ART NO.SIZE
MM X BS
BRASS VALVE
FLX24P 15 x 1/2”
FLX25P
Full Bore
22 x 3/4”
FLX31P 15 x 1/2”
FLX38P 15 x 3/4”
FLX32P
Full Bore
22 x 3/4”
PLAST C VALVE
FLX37P 15 x 1/2”
FLX39P 22 x 3/4”
PLAST C VALVE W TH HANDLE
FLX37-H 15 x 1/2”
FLX39-H 22 x 3/4”
300mm long
500mm long
BRASS F TT NGS
ART NO.SIZE
MM X BS
Converts Speedfit to male thread.
ART NO. SIZE
MM X BS T
MW051504N 15 x 1/2”
MW052206N 22 x 3/4”
MW052818N 28 x 1” BSP
Suitable for central heating systems.
Manufactured in DZR Brass.
ART NO. SIZE
MM X BS T
MW011504N BRASS 15 x 1/2”
MW012206N BRASS 22 x 3/4”
MW012808N 28 x 1”
Suitable for central heating systems.
Manufactured in DZR Brass.
ART NO.SIZE
MM X BS
22CFA 22 x 1
Suitable for central heating systems.
Manufactured in DZR Brass.
ART NO.SIZE
MM X BS
22CMA 22 x 1
Suitable for central heating systems.
Manufactured in DZR Brass.
SPEEDF T X UN ON NUT
SPEEDF T X SPEEDF T
SPEEDF T X UN ON NUT W TH SERV CE VALVE
BRASS MALE COUPLER
BRASS BACK PLATE ELBOW
BRASS MALE STEM ADAPTOR
BRASS MALE CYL NDER ADAPTOR
BRASS FEMALE CYL NDER ADAPTOR
11 12
150mm long
1000mm long
ART NO.SIZE
MM X MALE
FLX48 12 x M10
FLX28 15 x M10
FLX29 15 x M12
FOR MONOBLOC M XERS
ART NO.SIZE
MM X BS
ART NO.SIZE
MM X BS
FLX36P 15 x 1/2”
ELBOW PATTERN
300mm long
300mm long
300mm long
500mm long
ART NO.SIZE
MM X BS
FLX49 15 x 3/8”
SPEEDF T X MALE THREAD
300mm long
ART NO.SIZE MM
SPEEDF T X UN ON NUT
SPEEDF T X PLA N STEM
200mm long
SPEEDF T X SPEEDF T W TH SERV CE VALVE
BRASS VALVE
FLX44P 15 x 15
FLX45P 15 x 15
ART NO.SIZE
MM X MALE
FOR MONOBLOC M XERS
ART NO. SIZE
MM X BS
SPEEDF T X UN ON NUT W TH SERV CE VALVE
ART NO. I E STEM
WFLX51 15 15
DENT TY D SCS
ART NO. ACK QTY
WH TE PVC FLEX HOSES
WFLX15 15 x 1/2”
WFLX16 15 x 3/4”
WFLX22 22 x 3/4”
WFLX18 15 x 1/2”
WFLX20 15 x 3/4”
WFLX19 22 x 3/4”
ART NO.SIZE
MM X BS
300mm long
500mm long
ART NO. SIZE MM
WFLX17 15 x 15
SPEEDF T X SPEEDF T
300mm long
WFLX36 15 x 1/2”
ELBOW PATTERN
300mm long
ART NO. SIZE
MM X BS
ART NO.SIZE
MM X BS
10MC (1/2) BRASS 10 x 1/2”
15MC (1/2) BRASS 15 x 1/2”
22MC (3/4) BRASS 22 x 3/4”
MW012818N 28 x 1”
PLAST C VALVE W TH HANDLE
WFLX37-H 15 x 1/2”
WFLX39-H 22 x 3/4”
300mm long
WFLX28 15 x M10
WFLX29 15 x M12
300mm long
FLX - RED 10
FLX - BLU 10
1000mm long
SPEEDF T X PLA N STEM
300mm long
ART NO. I E STEM
FLX53 15 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C max.
For handles on service valves.
ART NO.SIZE
MM X BS
MW501514N 15 x 1/2”
MW502216N 22 x 3/4”
Suitable for central heating systems.
Manufactured in DZR Brass.
Converts Speedfit to female thread.
BRASS FEMALE STEM ADAPTOR
15WB 15 x 1/2"
22WB 22 x 3/4"
Manufactured in DZR Brass.
Suitable for central heating systems.
SHORT VERS ON
15WB2 15 x 1/2"
Manufactured in Brass.
Suitable for central heating systems.
VALVES
ART NO.SIZE MM
15 ESOT 15
ART NO.SIZE
15 APT 15mm x 3/4" BSP
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
For torque figures on plastic threads
please see Technical Checklist.
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.SIZE MM
15STV 15
22STV 22
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.SIZE MM
15SV 15
22SV 22
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.SIZE MM
15BDC 15
ART NO.SIZE MM
15DCV 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.SIZE MM
10HSV 10
15HSV 15
22HSV 22
Suitable for central heating systems.
Suitable for central heating systems.
Manufactured in DZR Brass.
Please note a collet cover cannot be used on
a Speedfit end assembled with a draincock.
Draincocks can be fitted with a standard
fitting fitted with a collet clip.
When using with Twist and Lock Fittings
the fitting must be locked.
ART NO.SIZE
15PTSV 15 x 1/2”
22PTSV 22 x 3/4”
Suitable for central heating systems.
ART NO.SIZE MM
15HSV-BRASS 15
Suitable for central heating systems.
P PE AND P PE ACCESSOR ES
ART NO.SIZE MM
CM1810S 10
CM1815S 15
CM1822S 22
CM1810W 10
CM1815W 15
CM1822W 22
CM1810R 10
CM1815R 15
CM1822R 22
CM1810B 10
CM1815B 15
CM1822B 22
Suitable for central heating systems.
White and grey collet clips prevent accidental
release of pipe from standard fittings.
Red and blue clips provide colour coding of pipe,
they should not be used to prevent accidental
release of pipe.
ART NO.SIZE MM
PKM1910W 10
PKM1910R 10
PKM1910B 10
AM1915W 15
PM1915R 15
PM1915B 15
AM1922W 22
PM1922R 22
PM1922B 22
Available in white, red or blue
Suitable for central heating systems
ART NO. SIZE
15BPEX-20x2L 15mm x 2m
15BPEX-20x3L 15mm x 3m
15BPEX-20x6L 15mm x 6m
22BPEX-20x2L 22mm x 2m
22BPEX-20x3L 22mm x 3m
22BPEX-20x6L 22mm x 6m
28BPEX-10x3L 28mm x 3m
28BPEX-10x6L 28mm x 6m
Suitable for central heating systems.
Straight lengths
The pipe has an inner barrier to
stop the ingress of atmosphere.
*By special order only.
ART NO.SIZE MM
TSM10N 10
TSM15N 15
TSM22N 22
TSM28N 28
Suitable for central heating systems.
To be used when connecting Speedfit Pipe
to a compression fitting.
See Page 16.
ART NO.SIZE
10BPEX-25C 10mm x 25m
10BPEX-50C 10mm x 50m
10BPEX-100C 10mm x 100m
15BPEX-25C 15mm x 25m
15BPEX-50C 15mm x 50m
15BPEX-100C 15mm x 100m
15BPEX-120C 15mm x 120m
15BPEX-150C 15mm x 150m
22BPEX-25C 22mm x 25m
22BPEX-50C 22mm x 50m
Suitable for central heating systems.
Coils
The pipe has an inner barrier to
stop the ingress of atmosphere.
British Gas accepted for water
pipe in vented and sealed central
heating systems.
ART NO.SIZE MM
STS10 10
STS15 15
STS22 22
STS28 28
Suitable for central heating systems.
To be used only when connecting
Speedfit Pipe and Speedfit Fittings
to enhance the sealing security of
the connections. See page 05.
ART NO. SIZE
BLACK
15BLK CON-25C 15mm x 25m
15BLK CON-50C 15mm x 50m
22BLK CON-25C 22mm x 25m
22BLK CON-50C 22mm x 50m
RED
15RED CON-50C 15mm x 50m
22RED CON-50C 22mm x 50m
BLUE
15BLU CON-50C 15mm x 50m
22BLU CON-50C 22mm x 50m
To be used when Speedfit Pipe is laid
in Concrete and Masonry, see section
on page 20.
*
ART NO. SIZE
CONELB F TS 10, 15 & 22mm
STOP VALVE
WASH NG MACH NE TAP
EMERGENCY SHUT OFF TAP
DOUBLE CHECK VALVE
PLAST C SERV CE VALVE
BRASS SERV CE VALVE
BRASS CHROME PLATED SERV CE VALVE
BRASS CHROME PLATED SERV CE VALVE
W TH TAP CONNECTOR
BRASS DRA N COCK
PEX BARR ER P PE
PEX BARR ER P PE
SUPERSEAL P PE NSERT
P PE NSERT
CONDU T P PE
CONDU T ELBOW
COLLET COVER
COLLET LOCK NG CL P
ART NO.SIZE MM
15BSC 15
Only suitable for central heating.
Head and Body manufactured in DZR Brass.
BRASS STOP TAP
13 14
Grey
ART NO.SIZE MM
10BV 10
15BV 15
22BV 22
Suitable for central heating systems.
BRASS CHROME PLATED BALL VALVE
White
Red Blue
ART NO.SIZE
15BPB-25C 15mm x 25m
15BPB-50C 15mm x 50m
15BPB-100C 15mm x 100m
15BPB-120C 15mm x 120m
15BPB-150C 15mm x 150m
22BPB-25C 22mm x 25m
22BPB-50C 22mm x 50m
Suitable for central heating systems.
Coils
The pipe has an inner barrier to
stop the ingress of atmosphere.
British Gas accepted for water
pipe in vented and sealed central
heating systems.
POLYBUTYLENE BARR ER P PE
Each Valve has a red and a blue indice.
ART NO.SIZE
15SVSTC 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PLAST C SERV CE VALVE W TH TAP CONNECTOR
ART NO.SIZE
15SVBTC 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PLAST C ANGLE SERV CE VALVE
W TH TAP CONNECTOR
ART NO. SIZE
15P P-50C-E 15mm x 50m
22P P-50C-E 22mm x 50m
P PE N P PE
ART NO.SIZE MM
PLAST C BALL VALVE
Not suitable for central heating systems.
Each Valve has a red and a blue indice.
15SV-H 15
22SV-H 22
Grey
White
Grey
White
ART NO. SIZE
15SVSTC-W 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
ART NO.SIZE
15SVBTC-W 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
Water-replenishing ring mains are typically used in hotels
and hospitals. They are maintained at a constant high
temperature to supply hot water to distribution pipes to
wards or hotel rooms which may be some way from the
heat source.
These systems are very different from more conventional
domestic hot water and central heating systems.
Speedfit Products cannot be used on ring main systems.
The exception would be those systems designed for
domestic situations which have an intermittent
temperature of less than a maximum of 65ºC. This is in
accordance with BS7291 Parts 1 and 3 Class S.
ART NO.
JG-TS
ART NO.
JG HDC
BLADE-JGHDC
ART NO.SIZE MM
PC15W 15
PC22W 22
PC28W 28
PCSW
For up to 22mm size pipe.
ART NO. SIZE MM
NPC10 10
NPC15 15
NPC22 22
NPC28 28
ART NO.SIZE MM
10CFB 10
15CFB 15
22CFB 22
To help create a tighter bend than
the minimum with unsupported pipe.
ART NO. SIZE MM
JG-BS10 10
JG-BS15 15
JG-BS22 22
For use with Female Coupler/Tap Connector.
PLUMB NG SPARE PARTS
ART NO.SIZE MM
PXC 10 10
PXC 15 15
SPF 22 22
PXC 28 28
PXC 10 10
PXC 15 15
PXC 22 22
PXC 28 28
ART NO.SIZE MM
10 EPR 10
15 EPR 15
22 EPR 22
28 EPR 28
ART NO.SIZE
1/2 EPW 1/2
3/4 EPW 3/4
10mm
15mm and 22mm
ART NO.SIZE MM
10RA 10
15RA 15
22RA 22
28RA 28
P PE AND P PE ACCESSOR ES
For Standard Fittings
For Twist and Locks Fittings
SYSTEM CONNECT ONS
The Speedfit Range includes couplers to connect
Speedfit Pipe to 1/2” to 1” BSP and BSPT. See page 12.
Many but not all compression fittings are suitable for use
with plastic fittings and pipe. Users should therefore
check for compatibility. Compression fittings with short
tube stop depth or brass olives should not be used with
plastic fittings or pipe.
When using compression fittings with Speedfit Pipe, a
Standard Pipe nsert (prefix TSM) must be used to
withstand the compressive pressure of the olive. The olive
must be located within the the length of the pipe insert
and the pipe fully inserted into the fitting. The connection
should not need more than 2 full turns after the olive has
gripped the pipe. JG Speedfit recommend the use of soft
copper olives.
n modern properties, water enters a building usually in
blue MDPE (medium density polyethylene) pipe. n order
to comply with Water Regulation Schedule 2.10, the
internal plumbing system should be connected via a
Speedfit Stop Valve (Part Nos. 15STV and 22STV) in
conjunction with a PE-Copper Coupler from the Speedfit
range of Underground Fittings.
Speedfit fittings can be connected onto chromium plated
copper pipe if the chromium plating is completely
removed to the full depth of the fitting. To ensure
maximum grip, the fitting of a collet clip is recommended.
Connection of Speedfit
pipe to supply pipe of other
materials should be via a
stop tap with a 15mm or
22mm compression outlet.
Compression fitting Standard Pipe insert
Olive
Speedfit Pipe
with Superseal Pipe Insert
Stop valve
Copper pipe
PE copper coupler
MDPE pipe with
Pipe Insert
Collet clip
Speedfit Pipe
Speedfit pipe should never be connected directly to a boiler.
Although most modern boilers have a high limit
thermostat, residual heat can be conducted by the heat
exchanger. Therefore, Speedfit recommend a minimum of
1 metre from the boiler casing should be run in copper
pipe unless otherwise stated in the boiler manufacturers
installation literature.
A gravity primary circuit operating on an uncontrolled
cooking range or solid fuel boiler should be run entirely in
copper and the heating circuit run in copper for the first metre
.
Refer to BS 5955: Part 8 for further clarification.
All appliances should have safety devices to make sure
they cannot operate above the working temperature and
pressure range set out in our Technical Checklist on page
29. f safety devices are not incorporated within the
appliance then external controls will be needed.
Water meters (and other devices) can contain check
valves that prevent the expansion of heated water back
down the main supply from a combi boiler. f plastic pipe
is to be used, a suitable expansion vessel must be fitted.
This is especially important to consider if a water meter is
fitted retrospectively. Speedfit do not recommend the use
of plastic pipe on the main supply between a water meter
and a combi boiler if an expansion vessel is not fitted.
Speedfit Products should not be fitted to a sealed system
oil boiler, back fired boiler or other uncontrolled heat source.
Please also see Drop-Pipe Systems on page 17 and
System Commissioning and Fl shing on page 21.
Ensure nut and olive are in place before inserting pipe insert.
t is not possible to connect Speedfit fittings to Stainless
Steel Pipe.
Fittings to connect imperial
pipe to metric pipe are
shown on page 10.
RELEASE A D
COLD FORM NG BEND
BEND NG SPR NG
P PE CUTTER
HEAVY DUTY P PE CUTTER
P PE CL PS AND SPACERS
NA L CL P
COLLETS
EPDM ‘O’ R NG
THREAD WASHER
CONNECT ON TO COMPRESS ON F TT NG
CONNECT ON TO MPER AL P PE AND F TT NGS
CONNECT ON TO CHROME-PLATED COPPER P PE
CONNECT ON TO MA NS SUPPLY
CONNECT ON TO R NG MA NS
CONNECT ON TO BO LERS
Speedfit can be used on sealed and open vented heating
systems, where boilers are either heating a hot water
storage cylinder or instantaneous hot water such as a
combination boiler. The temperature and pressure limits
of the system must not exceed the maximum values stated
under the heading ‘Working Temperatures and Pressures’.
When using a traditional copper vented cylinder Speedfit
pipe and fittings can be installed with direct connections
to the cylinder.
As shown in the Product Range List, the Speedfit range of
fittings includes valves, taps, adaptors and connectors for
the plumbing of all typical domestic appliances and fittings.
CONNECT NG TO OTHER PLUMB NG F XTURES
CONNECT ON TO CYL NDER & WATER HEATERS
15 16
For up to 28mm size pipe.
Allows a firmer grip on the
collet when removing pipe.
ART NO.SIZE MM XM
JGTAPE 50 x 45
FO L TAPE
Metallic tape to meet NHBC requirements
for plastic pipe to be detected inside walls.
The Speedfit range includes a Double Check Valve
(Part No 15DCV) to enable installers to comply with Water
Regulation
Schedule 2.15,
thus preventing contamination
of water arising from
back siphonage,
backflow or
cross connection.
Washer
Hole dia.
15mm pipe 29mm
22mm pipe 36mm
28mm pipe 46mm
Cold water tank
The minimum distance to make a solder connection on
copper pipe inserted into a Speedfit Fitting is 450mm
(18 inches). Ensure that any residual flux solder is not
allowed
to come in contact with the fitting. That same
measurement
is the safe distance to use a freezer kit to
Speedfit Pipe.
Care should be taken when designing and installing a
central heating system where radiators are supplied by
pipe work which drops from an upper floor.
With this kind of system it is possible to trap air in the
upper floor pipe work. When the boiler is fired the increase
in pressure within the pipe caused by expanding air could
cause the pipe to burst.
t is therefore essential that the system be designed so
that any air can be removed from the system either
automatically or manually by installing automatic or
manual air vents at the highest points of the system.
Speedfit pipe should not be used to provide the discharge
from unvented cylinders, unvented water heaters and sealed
systems via the temperature relief and pressure relief values.
Speedfit recommend that mains supply pipework to unvented
water heaters (up to 15ltr capacity), be run in metal pipes.
Speedfit pipe should be connected to circulating pumps,
motorised valves in accordance with the section in this
book headed, “Connecting Plastic Pipe To Compression
Fittings”. f Speedfit pipe is not mounted on a supporting
structure, the pipe must be clipped close to the components’
connections to ensure adequate support and to assist in
the reduction of vibration.
For heavier equipment, ensure that appropriate metal
brackets provide full and independent support of the
components and that it does not rely solely on the pipework
for support.
To install the Speedfit Tank Connector, unscrew the nut
and push the body of the fitting through the tank hole with
the washer on the inside of the tank.
Hand tighten the nut onto the body. Push the pipe into
the connector.
Note: Hand tightening the nut onto the body is all that is
required. Further mechanical tightening will damage the fitting.
Maximum wall thickness of tank 4mm
EE Guidance Note 7 provides useful guidance on the
design of electrical installations where there is increased
risk of electric shock. t recognises that the requirement
for supplementry bonding may be relaxed where metal
taps and plastic pipes supply other bathroom fittings.
Similarly a metal bath or radiator not connected to an
extraneous-conductive-part is not required to be connected
to the local supplementry conductors.
Metal
Pipe
Metal
Pipe
Speedfit Pipe and Fitting
Clip Clip
Earth Lead
The most common way of running pipework to a radiator
is to run both flow and return pipes central to the
radiator position.
Once the plasterboard is installed the pipes are passed
through the Speedfit Radiator Outlet Plate to exit
plasterboard without the need of unsightly holes.
Metal reducing sets which convert radiator valves from
15mm to 10mm are not suitable for use with Speedfit
Fittings or Pipe as they can cause damage to the plastic.
Pipe Supplementary Bond Comments
Material Required Between
Earth terminals of
protective conductors of
class I and of class II
equipment and accessible
exposed conductive parts
of the building structure.
Hot water pipe, central
heating pipes, earth
terminals of protective
conductors of class I and
class II equipment and
accessible exposed
conductive parts of the
building structure.
Central heating pipes, the
earth terminals of
protective conductors of
class I and class II
equipment and access to
exposed conductive parts
of the building structure.
All metal pipes,
earth terminals of
protective conductors
class I and class II
equipment, and accessible
exposed conductive parts
of the building structure.
All metal pipes,
earth terminals of
protective conductors of
class I and class II
equipment, and accessible
exposed conductive parts
of the building structure.
Bonding of metal taps
metal radiatorsor metal
baths is not required
unless the bath is
connected to the
metallic building structure.
A bond is not required
to the taps either hot
nor cold, or to metal
baths unless connected
to the metallic
building structure.
Bonding of metal water
taps is not required,
nor metal baths unless
connected to the metallic
building structure.
Metal pipes themselves
can be used as bonding
conductors if joints are
metal to metal and
electrically continuous.
Metal central heating
radiator does not
require bonding.
Cold Hot Central
Water Water Heating
P PP
PMM
PPM
MMM
MMP
P= Plastic M= Metal NB: All Waste Pipes are plastic.
1. Supplementary bonding is carried out to the earth terminal
of protective conductors of class and class equipment
within the bathroom. A supplementary bond is not run
back to the main earth.
2. Metal window frames are not required to be supplementary
bonded unless they are electrically connected to the
metallic structure of the bonding.
3. Metal baths supplied by metal pipes do not require
supplementary bonding if all the pipes are bonded and
there is no other connection of the bath to earth.
4. All bonding connections must be accessible and labelled
“Safety Electrical Connection - Do Not Remove”.
DROP-P PE SYSTEMS
D SCHARGE P PES
WATER HEATERS
CONNECT ON TO PUMPS AND VALVES
CONNECT ON TO COPPER P PE
CONNECT NG TO COLD WATER STORAGE TANK
PREVENT NG BACK FLOW
RAD ATOR CONNECT ONS
ELECTR CAL CONT NU TY CONT’D
SUPPLEMENTRY BOND NG TO BATHROOMS
NSTALL NG P PEWORK
Speedfit Barrier Pipe is manufactured to BS 7291 Parts 1,
2 and 3 Class S and is Kitemarked.
The pipe is available in coils and straight lengths. See
pages 14. Pipe markings are spaced to aid the making of
a good connection when using a Superseal Pipe nsert.
15mm B-PEX to BS7291 : Part 3 : 1990 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C
t is made up of 5 layers, the
centre of which is a blue
coloured oxygen barrier
which prevents the ingress
of air into the system, thereby
reducing the effect of corrosion
on metal components.
Because of it’s low thermal conductivity, when carrying
hot water, Speedfit Pipe is cooler and therefore safer to
touch. Relatively low heat loss through radiation means that
a system retains it’s heat longer and delivers hot water
more quickly and with less wastage than a metal system.
SPEEDF T BARR ER P PE
For general guidance on pipework sizing, please refer to
BS6700 or the nstitute of Plumbing Engineering Services
Design Guide. Speedfit fittings are suitable for pipes
within ±0.1mm of nominal size. They can be used with
copper pipe to BS EN 1057 or Speedfit plastic pipe.
The Product Range List shows the fittings available for
reducing pipe diameters within the system.
Speedfit pipe is available in straight lengths and coils.
Pipe Diameter
Straights 2m - 15mm 22mm -
3m - 15mm 22mm 28mm
6m - 15mm 22mm 28mm
Coils 25m 10mm 15mm 22mm -
50m 10mm 15mm 22mm -
100m 10mm 15mm --
120m - 15mm --
150m - 15mm --
P PEWORK S Z NG
17 18
22mm Barrier-PB to BS7291-2 2001 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C
The pipes exit a single
gang box (fitted with rubber
grommets)
located at the
mid height of the finished
radiator position. This also
provides a fixed point for
other trades to work to and
reduces the risk of damage
to the pipework.
Unvented pressurised cylinders can be installed using
Speedfit Pipe and Fittings. However, insertion depths on
compression joints that form part of the cylinder must be
checked prior to installation and the use of standard pipe
inserts (Prefix TSM) is recommended.
n accordance with current U.K. Building Regulations
(Part G), discharge pipes from temperature and/or pressure
relief valves must be run in metal pipework.
Speedfit connections to combined Cylinder/Boiler
units and Thermal Storage Units must be made outside
the casing unless otherwise stated in manufacturers
installation literature.
CONNECT ON TO CYL NDER & WATER
HEATERS CONT NUED
The plumbing or heating system installer should have
these aspects checked to ensure compliance with current
EE regulations. f in doubt please contact the Speedfit
Technical Advisory Service or your local Electricity Authority.
ELECTR CAL CONT NU TY
UNVENTED PRESSUR SED CYL NDERS
Unvented Pressurised Cylinders can be installed using
Speedfit pipe and fittings. However if the safety
parameters of the cylinder exceed those of the pipe and
fittings it is possible to fit a pressure reduction valve on
the out going hot supply pipe. This will not interfere with
any other cylinder safety devices demanded by
regulations as they are all fitted in the incoming side of the
cylinder. Run a short length of copper pipe from the
cylinder connection (about 150mm - 300mm) then fit a
Honeywell DO5F pressure reduction valve. This will
protect the pipe and fittings from excessive pressure in
the event of boiler / cylinder malfunction. The factory
fitted temperature / pressure relief valve on the cylinder
will discharge below 100˚C therefore protecting the pipe
from excessive temperature.
JG Speedfit aluminium foil tape can be used to fulfil the
NHBC requirements for the identification of location of
plastic pipes in or behind a wall surface by a metal
detector. t features a bright aluminium finish, rubber/resin
high-tack adhesive and quality siliconised backing paper
to allow the easy handling of short, cut lengths.
D
DO
O
N
NO
OT
T
s
st
ti
ic
ck
k
t
th
he
e
t
ta
ap
pe
e
t
to
o
t
th
he
e
S
Sp
pe
ee
ed
df
fi
it
t
p
pi
ip
pe
e
o
or
r
f
fi
it
tt
ti
in
ng
gs
s
o
or
r
t
th
ho
os
se
e
o
of
f
a
an
ny
y
o
ot
th
he
er
r
m
ma
an
nu
uf
fa
ac
ct
tu
ur
re
er
r.
.
METAL FO L TAPE