Judo PIPE-CARE SYSTEM User manual

Installation and operating instructions
JUDO PIPE-CARE SYSTEM
Micro leakage protection system ¾" - 1¼"
Valid for: EU-countries and Switzerland
Language: English
Read before use and store!

Queries, orders, customer service
JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Email: [email protected] • judo.eu
Office address:
JUDO Wasseraufbereitung GmbH
Hohreuschstraße 39 - 41
D-71364 Winnenden
Trademarks:
Trademarks used in this document are the
protected and registered trademarks of the
owners.
© JUDO Wasseraufbereitung GmbH
D-71364 Winnenden
All rights reserved.
Reprinting, even in excerpt form, is only per-
mitted with special approval.
Dear customers,
Thank you for the confidence you have
shown in us by purchasing this prod-
uct. You have purchased a state-of-the-
art device. It has been carefully checked
prior to delivery. Nevertheless, if diffi-
culties occur, please contact the closest
customer service (see chapter Customer
service).
These installation and operating instructions
are intended for both installers, who are in
charge of installing, maintaining or repair-
ing the device, and for the operators of the
device.
2 JUDO JPCS 1703593 • 2022/10

Contents
Contents
1 Safety......................................... 4
1.1 Intended use............................... 4
1.2 Application limits......................... 4
1.3 Safety instructions....................... 4
1.4 Symbols used............................. 6
1.5 Units used................................... 6
1.6 Normative basics........................ 6
2 Product information.................. 7
2.1 Scope of supply.......................... 7
2.2 Function description.................... 7
2.3 Materials used............................ 8
3 Installation................................. 9
3.1 Conditions................................... 9
3.2 Installation of the rotary flange
fitting............................................ 9
3.3 Installation of the device............. 10
3.4 Commissioning............................ 11
4 Operation................................... 11
4.1 Status display............................. 11
4.2 Possible settings......................... 11
4.3 Menu key - selectable functions
and settings................................ 13
4.4 Setting limit values...................... 19
4.5 Automatic operation.................... 21
4.6 Automatic shut-off of the water
supply.......................................... 21
4.7 Emergency-open function........... 22
4.8 Displaying operating data and
information.................................. 22
4.9 Conversions, changes................ 23
4.10 Maintenance, repair, spare parts 23
4.11 Temporary removal of the
device.......................................... 23
5 Remote control and Remote
transmission of messages....... 24
5.1 External messages..................... 24
5.2 Integration in building control
systems....................................... 24
6 Warning message / fault........... 25
7 Servicing.................................... 28
7.1 Cleaning...................................... 28
7.2 Warranty and maintenance......... 28
8 Technical data........................... 29
8.1 Installation dimensions................ 31
8.2 Connection options..................... 32
8.3 Accessories................................. 33
8.4 Electronic control unit................. 34
8.5 Spare parts................................. 36
9 Disposal..................................... 37
10 EC Conformity Declaration...... 38
11 Maintenance log........................ 39
12 Customer service...................... 40
1703593 • 2022/10 JUDO JPCS 3

Safety
1 Safety
These operating instructions must always
be available at the place of use of the
device.
1.1 Intended use
The device is intended to shut off the water
supply to drinking water systems, upon
exceeding of the settable values for
•maximum withdrawal time
•maximum water quantity
•maximum water volume flow
for protection against water damage, water
loss and unwanted water consumption.
It can be installed in all commercially avail-
able drinking water pipes. Installation and
use are subject to the applicable national
conditions.
1.2 Application limits
1.2.1 Water quality
The water must comply with the European
Drinking Water Directive (98/83/EC). Before
using the device with water that does not
comply with this Directive, it is essential to
consult the manufacturer.
1.2.2 Water pressure
CAUTION
The water pressure must not exceed
16 bar input pressure. The device
must not be installed if the mains
pressure is above 16 bar (even for a
short time)!
Nominal pressure PN 16
1.2.3 Water and ambient tempera-
ture
The filter is suitable for use in cold drinking
water up to a maximum water and ambient
temperature of 30 °C.
1.3 Safety instructions
DANGER
The device could reduce or cut
water supply for equipment down-
stream requiring constant readi-
ness for water withdrawal (e.g.
thermal flow protection, sprinkler
system).
This could result in fires or explo-
sions.
If there are downstream safety
devices and the water supply line
to these devices does not branch
off upstream of the device, then
the device must not be installed!
DANGER
The motorised ball valve is
installed on the rear side of the
device. When the device is not
installed, the ball valve can be
reached with the finger through the
opening on the rear.
If the device is commissioned or
connected to the mains without
being installed, there is a risk of
crushing due to rotating parts.
Never operate the device or con-
nect it to the electrical mains if it is
not fully installed!
Never put your finger in the open-
ing on the rear side of the device!
4 JUDO JPCS 1703593 • 2022/10

Safety
1.3.1 Electrical danger
ELECTRO_NO_HEADER
Risk of electric shock
Only the supplied power supply unit may
be used to connect the unit to the power
supply. This reduces the mains voltage
for operating the electronics to a harm-
less low voltage of 24 V.
A splash-proof socket above the device,
at a distance of no more than 1.5 m, is
required for connection to the mains, in
accordance with the legal regulations for
wet rooms.
The power supply unit must be discon-
nected to make the electrical installation.
1.3.2 Warning of property damage
WARNING
Risk of water damage or damage
to property
The device may only be installed by
qualified technical personnel.
The installation room must be dry and
free from frost.
The ambient temperature must not
exceed 30 °C! In higher temperatures
or direct sunlight, material damage may
occur up to and including breakage of
device parts.
The pipe must be able to safely support
the device (weight: see chapter 8). If nec-
essary, the pipes must be provided with
additional fastenings or support.
If no bypass valve is installed, a shut-
off valve must be installed upstream and
downstream of the device in order to
interrupt the water supply during instal-
lation, maintenance, repair or malfunc-
tion of the device.
For the installation of the device in
domestic water piping, only use the sup-
plied built-in rotary flange (see chap-
ter(siehe Kapitel 3.2 ).
The flange surface of the rotary flange
fitting must be upright!
The rotary flange fitting must be fitted so
that it is free from mechanical stress or
strain. Otherwise mechanical damage to
the pipe or the rotary flange fitting up to
and including breaks can result.
For proper sealing the profile of the pro-
file flange seal must point towards the
rotary flange fitting (siehe Figure 4).
Only operate the device in a technically
faultless condition:
•Check for damage prior to installa-
tion.
•Immediately have any malfunctions
in operation rectified by qualified
technical personnel.
The appliance must not be exposed to
strong vibrations.
The mains voltage must not be inter-
rupted (e.g. via a light switch). If the
device is not permanently supplied with
power,
•a possible leakage cannot be
detected.
•the leakage protection cannot close
in the event of a leakage.
Persons who, due to their physical, sen-
sory or mental abilities or their inexperi-
ence or lack of knowledge, are unable to
operate the device safely may not oper-
ate it without supervision or instruction
from a responsible person.
After the leakage protection has closed
due to a limit being exceeded, first check
whether there is a leak before opening
the leakage protection again.
If there is a device for hot water prepa-
ration (in particular a gas or electrically
operated instantaneous water heater
or a heating boiler), the manufacturer's
instructions for the water heater must
1703593 • 2022/10 JUDO JPCS 5

Safety
be observed before opening the leakage
protection (instructions for venting).
Do not use household cleaning agents to
clean the outside of the device, but only
use clear water to avoid embrittlement of
the plastic.
The device may only be repaired by qual-
ified technical personnel.
Only use original spare parts for repairs.
Before performing work on the device
that goes beyond pure operational use,
the device must be depressurised! If
this is ignored, the result may be uncon-
trolled escape of water resulting in water
damage to the building/home.
If the device is removed due to an inter-
ruption of operation:
•Protect the flange surfaces against
damage to ensure proper sealing.
•Protect the device from dirt so as not
to impair drinking water hygiene.
•Store the device in a frost-free place
to prevent damage caused by freez-
ing water and leakage.
Unauthorised conversions and changes
are forbidden for safety reasons. These
can impair the functioning of the device,
leading to leaks and, in the worse case
scenario, to bursting of the device.
1.4 Symbols used
The safety instructions contained in these
operating instructions are labelled with the
following symbols:
Indication of existing dangers
Warning of electric voltage
User tips and other information
Instructions attached directly to the device,
e.g.:
•Direction of flow (arrow)
•Type label
•Cleaning information
must be observed and maintained in legible
condition.
1.5 Units used
Unit Conversion
bar 1 bar = 105 Pa = 0.1 N/mm2
¾" DN 20
1" DN 25
1¼" DN 32
1.6 Normative basics
This device has been designed and
manufactured according to
•DIN 3553 (Leakage protection systems
with sensors and automated shut-off
devices, requirements and tests)
6 JUDO JPCS 1703593 • 2022/10

Product information
2 Product information
2.1 Scope of supply
•Micro leakage protection system, pre-
assembled
•Installation and operating instructions
2.2 Function description
The device measures the water flow and
monitors the set limit values for water with-
drawal. Water flow is shut off if limit values
are exceeded.
Monitored limit values:
•maximum water quantity in litres
•maximum water flow in litres per hour
•maximum water withdrawal time in min-
utes
These limit values
•are automatically determined and set in
a learning mode phase during the flow
of the first 10 m³ of water.
•can also be modified via the menu.
INFO_NO_HEADER
The teach-in mode can be restarted
at any moment when requested.
To ensure fault-free operation, the leakage
protection system is equipped with auto-
matic mechanisms that prevent faults.
Fig. 1: Function description
1 Control panel
2 Display
3 Rotary flange fitting
4 Nameplate with instructions for emer-
gency open function
Fig. 2: View from below: LAN cable
connection
INFO_NO_HEADER
The LAN connection is available if the
connectivity module (available as an
accessory) has been installed.
1703593 • 2022/10 JUDO JPCS 7

Product information
2.2.1 Control panel
Fig. 3: Leakage protection control panel
1 Two line display
2 Keyboard
The leakage protection unit is operated via
the keyboard.
Functions of the individual keys:
Menu key
- Access to the Setting menu
Arrow key
- Scroll up in the menu
- Increase value
Arrow key
- Scroll down in the menu
- Reduce value
Back key
- Jump one menu level back without
saving
OK key
- Access to the sub-menu
- Accept value and save, then jump
one menu level back
- Acknowledge message
Meaning of the display’s background
lighting:
None: Operating state without
water flow
Blue flashing
light:
Operating state with
water flow
White: upon pressing of a key
Yellow: for warning messages
Red: for fault indications
2.2.2 Sleep mode
Limit value monitoring can be deactivated
during a pre-set time to allow transport of
large water volumes (for garden irrigation,
filling pools etc.).
2.2.3 Vacation mode
During longer absences, the limit values can
be easily reduced or the water supply can
be completely shut off.
2.2.4 Micro leakage testing
Micro leakage testing can be performed to
detect leaks in the water pipe system even if
they are very small.
2.2.5 Emergency-open function
In case of emergency (e.g. power failure
during a building fire), the leakage protec-
tion shut-off valve can be opened and shut
without power supply (see 2.2.5).
2.2.6 Remote monitoring and con-
trol
The device can be integrated in building
control systems (see chapter 5).
2.3 Materials used
The materials and substances used are
resistant to the physical, chemical and cor-
8 JUDO JPCS 1703593 • 2022/10

Installation
rosive loads expected to be encountered in
drinking water.
The materials and substances in contact
with drinking water fulfill the requirements
of §17 of the German Drinking Water Ordi-
nance, which are available in concretised
form in the current assessment bases and
guidelines of the Umweltbundesamt (Ger-
man Federal Environment Agency).
3 Installation
CAUTION
The device may only be installed
by qualified technical personnel.
Installation of the device upstream of the
domestic water meter is forbidden.
3.1 Conditions
CAUTION
Risk of property damage or water
damage!
The pipe must be able to safely
support the device (weight: see
chapter 8). If necessary, the pipes
must be provided with additional
fastenings or support.
3.1.1 Requirements for the place of
installation
CAUTION
The installation room must be dry
and free from frost.
The ambient temperature must not
exceed 30 °C! In higher temper-
atures or direct sunlight, mater-
ial damage may occur up to and
including breakage of device parts.
If no bypass valve is installed, a
shut-off valve must be installed
upstream and downstream of the
device in order to interrupt the
water supply during installation,
maintenance, repair or malfunction
of the device.
A splash-proof socket above the
device, at a distance of no more
than 1.5 m, is required for connec-
tion to the mains, in accordance
with the legal regulations for wet
rooms.
The appliance must not be
exposed to strong vibrations.
In general the device is installed upstream
of the protective filter.
3.2 Installation of the rotary
flange fitting
CAUTION
The flange surface of the rotary
flange fitting must be upright!
The rotary flange fitting must
be fitted so that it is free from
mechanical stress or strain. Oth-
erwise mechanical damage to the
pipe or the rotary flange fitting up
to and including breaks can result.
The built-in rotary flange serves as a con-
necting element between the domestic
water installation and the device. It is suit-
able both for horizontal and vertical pipes.
It consists of:
•rotary flange fitting
•profile flange seal
•two union nuts
•two pipe sockets
•two flat seals.
Attention: Install the built-in rotary flange
in the flow direction! This is indicated by an
arrow integral with the casting.
INFO_NO_HEADER
If the installation is twisted, a func-
tioning of the device is not possible.
1703593 • 2022/10 JUDO JPCS 9

Installation
1 2
Fig. 4: Rotary flange fitting
1 Profile flange seal
2 Flow direction arrow
Procedure:
1. Loosen the two union nuts of the built-
in rotary flange and remove them with
the pipe sockets from the built-in rotary
flange fitting.
2. Fit the two pipe sockets with union nut
into the pipeline.
3.3 Installation of the device
CAUTION
For proper sealing the profile of
the profile flange seal must point
towards the rotary flange fitting
(siehe Figure 4).
Fig. 5: Placing and engaging the device
(fastening principle)
1 Feed screws through
2 Turn clockwise to engage
Fig. 6: Device connection engaged
(fastening principle)
Initial situation:
•The rotary flange fitting is installed in
the pipe and still closed with the mount-
ing cover.
Do not undo the screws on the device!
1. Open the shut-off valve upstream of the
installation location or the stopcock and
flush the pipe with the newly installed
rotary flange fitting by opening a down-
stream withdrawal point.
2. Close the withdrawal point again and
shut off the water again upstream of the
installation location (stopcock or shut-
off valve).
3. Remove the mounting cover of the
rotary flange fitting AND the respective
fastening screws.
4. Insert the heads of the four flange
screws of the device through the bay-
onet holes on the rotary flange fitting
(see Figure 5).
5. Turn the device in a clockwise direc-
tion as far as it will go (see Figure 5 and
Figure 6).
6. Tighten the four flange screws.
UNIT
Select the tightening torque (about
4 Nm) so that the seal is effective
and the device is not damaged or
strained!
10 JUDO JPCS 1703593 • 2022/10

Installation
3.4 Commissioning
Prior to initial commissioning (or to com-
missioning after maintenance work) fill the
installed device with water and vent:
1. Open the upstream shut-off valve to
fill the device with water. The device is
now under mains pressure.
2. Fully open a water tap downstream of
the device. After a flushing water quan-
tity of about 5 litres, the device is bled.
3. Plug the power supply unit in.
The control system checks the position
of the shut-off valve. If the shut-off valve
is open, the display shows:
Initial position
leakage protect
The device is ready for operation.
4 Operation
4.1 Status display
During normal operation the status dis-
play is displayed:
Leakage protect
opened
Letter “L“ at the end of the 2nd line:
•“L”: The device is in learning mode (see
chapter 4.4.3).
4.2 Possible settings
The following settings can be made via
the key Menu (Selection Setting):
Submenu
item
Setting
Language German, English, French,
Dutch, Italian
Submenu
item
Setting
Leakage pro-
tection (see
chapter 4.4)
Limit values
Vacation mode
Sleepmode time
Auto. testing (micro leak-
age testing)
Date Day / month / year
Time Hours / minutes
Backlight 10 % to 100 %, in 10%
steps
Contrast 10 % to 100 %, in 10%
steps
Tone Off / on / interval 6 h
Message
relay
Set fault indication relay as
normally closed contact /
normally open contact
Factory set-
ting
Recreate factory setting;
see chapter 4.2.1)
Procedure:
1. Press Menu key.
2. Navigate to Setting using the arrow
keys and confirm with the OK key.
3. Navigate to the desired setting (e.g.
date) and confirm with the OK key.
4. Using the arrow keys navigate to the
desired setting (e.g. set date) and con-
firm with the OK key.
1703593 • 2022/10 JUDO JPCS 11

Operation
4.2.1 Factory settings
The device is set as follows when deliv-
ered:
Setting for: Set to:
Language English
Leakage protect - limit
value for maximum with-
drawn time
30 min
Leakage protect - limit
value for max. water flow
4000 L/h
Leakage protect - limit
value for maximum
water quantity
500 L
Leakage protect - vaca-
tion mode
Vacation mode
on, U1
Leakage protect -
Sleepmode time
6 h
Leakage protect -
Auto testing
(micro leakage testing)
Auto testing off
Backlight 80 %
Contrast 50%
Tone - leakage warning on
Tone - fault 6 h
Message relay Normally closed
INFO_NO_HEADER
Upon resetting to the factory settings,
the above mentioned settings are
recreated.
Resetting to factory setting
All settings that have been made can be
reset to the factory setting as follows:
1. Press MENU key.
2. Using the arrow keys navigate to the
Setting menu item and press OK.
3. Using the arrow keys navigate to the
Factory setting menu item and press
OK.
4. Using the arrow keys select the follow-
ing setting and confirm with the OK key:
Factory setting
<yes>
The standard settings are recreated
(see chapter4.2.1).
12 JUDO JPCS 1703593 • 2022/10

Operation
4.3 Menu key - selectable func-
tions and settings
The following can be selected or set via
the menu key:
•Close (manually close leakage protec-
tion)
•Sleep mode (pause limit value monitor-
ing for a specified time)
•Vacation mode (limit values can be eas-
ily reduced or the water supply can be
completely shut off)
•Micro leakage testing
•Learn mode (determine limit values
from water flow)
•Settings (see chapter 4.2)
•Operating data
•Info
Procedure:
1. Press the menu key, to call the main
menu.
Main menue
Language
2. Use the keys ▲ and ▼ to navigate
through the sub-menu. Confirm the
desired sub-menu item with the OK key.
3. Then use the keys ▲ or ▼ to select the
desired setting and confirm with the OK
button.
The desired setting is saved.
1703593 • 2022/10 JUDO JPCS 13

Operation
4.3.1 Menu structure
M key
Close
Sleep mode
Vacation mode
Micro leakage
testing
Learn mode
Settings
Sprache /
Language
Leakage
protection
Date
Time
Backlight
Contrast
Tone
Message relay
Factory setting
Leakage protection
Limit values
Leakage protection
Vacation mode
Leakage protection
Sleepmode time
Leakage protection
Auto testing
Operating data
Info
Tot. water
quantity
Device number
Service no.
History
Water flow
Withdrawal time
Water flow
Water quantity
off
U1
U2
1 to 10 h
U3
Auto testing
on / off
Auto testing
Message only?
Auto testing
on
Auto testing
off
Auto testing
Message only
Auto testing
Message+close
Control unit SW-Version
Control unit HW-Version
Leakage protection
Input (LS)
Input (LS)
Floor sensor
Input (LS)
Sleep mode
Input (LS)
Close mode
14 JUDO JPCS 1703593 • 2022/10

Operation
4.3.2 Manually close or open leak-
age protection
Close leakage protection:
1. Press Menu key.
2. Using the arrow keys, select menu item
Close and press key OK. The following
appears on the display:
Leakage protect
close <OK>
3. Press OK to confirm. The following
appears on the display in an alternating
manner (with a yellow background):
Leakage protect
closed
To open
press <OK>
Water supply is shut off by the leakage
protection system.
INFO_NO_HEADER
The Menu key is deactivated in
this state.
To open the leakage protection system:
Press OK key.
The leakage protection system opens
for water supply. The default status dis-
play appears.
4.3.3 Temporary deactivation of
the leakage protection (sleep-
mode)
Situations in which large water volumes are
required on a one-off basis, e.g.
•Watering the garden
•Filling the swimming pool
•Filling the garden pond
may require the switching off of limit value
monitoring. This is referred to as "Sleep
mode".
INFO_NO_HEADER
No monitoring of water consumption
takes place in sleep mode.
Activation of sleep mode:
1. Press Menu key.
2. Select sleep mode using the arrow keys
and confirm with the OK key.
The following appears on the display:
Start
sleep mode <OK>
3. Press OK to confirm.
Sleep mode starts. The following
appears on the display in an alternating
manner (with a yellow background):
Leakage protect.
6 hours off
To end
press <OK>
The countdown of the displayed sleep
mode time runs. During this time, limit
value monitoring is paused.
1703593 • 2022/10 JUDO JPCS 15

Operation
INFO_NO_HEADER
The default sleep mode time of
6 h can be changed in hour steps
to another value in the range 1 to
10 h.
After the sleep mode time has
elapsed, limit value monitoring
starts again and the default sta-
tus display appears.
The Menu key is deactivated in
sleep mode.
Cancel sleep mode:
Press OK key.
Normal limit value monitoring starts
again. The default status display
appears.
4.3.4 Activation of vacation mode
During longer absences, the limit values
for water withdrawal can be reduced or the
water supply can be completely shut off.
There are two possibilities:
•immediate manual activation
•automatic activation after approx.
72 hours without water flow
INFO_NO_HEADER
Vacation mode remains active until
key OK is pressed (the vacation
mode message then disappears).
Key Menu is deactivated during vaca-
tion mode.
I. Immediate activation of vacation mode
(manual)
1. Press Menu key.
2. Select Vacation mode using the arrow
keys and confirm with the OK key. The
following appears on the display:
Vacation mode
Start <OK>
3. Press OK to confirm.
Vacation mode is activated. The fol-
lowing appears on the display in an
alternating manner (with a yellow back-
ground):
Leakage protect.
in vacation mode
To end
press <OK>
II. Setting vacation mode automatic acti-
vation
There are four different settings for
automatic activation:
°off (no automatic activation of vaca-
tion mode)
°U1 (= limit values 500 L/h • 50 L •
5 min)
°U2 (= limit values 1000 L/h •
100 L • 10 min)
°U3 (= shut-off valve closed - no
water flow)
1. Press Menu key.
2. Navigate to Setting using the arrow
keys and confirm with the OK key.
3. Navigate to Leakage protection using
the arrow keys and confirm with the OK
key.
4. Navigate to Vacation mode Leakage
protection using the arrow keys and
16 JUDO JPCS 1703593 • 2022/10

Operation
confirm with the OK key.
5. Select die desired setting (off • U1 • U2
• U3) using the arrow keys and confirm
with the OK key.
The selected vacation mode is saved.
To terminate vacation mode:
Press OK key.
Vacation mode is terminated. Normal
limit value monitoring starts again. The
default status display appears.
4.3.5 Micro leakage testing, manual
or automatic
The device also has the option of being able
to promptly detect small leaks.
Micro leakage testing can be started man-
ually at any time (see Starting micro leak-
age testing manually, page 19), but can
also take place automatically (see Perform-
ing small leakage testing automatically,
page 17).
If the leak cannot be found, even though a
micro leakage is repeatedly detected, the
installer or a professional company should
carry out a leak detection on the installation,
in order to find any possible leaks.
INFO_NO_HEADER
Automatic micro leakage testing is
deactivated upon delivery and can be
activated if desired.
If automatic micro leakage testing is
activated with subsequent setting to
message and closing of the water
supply, it is possible that frequent
shutting off of the water supply can
occur because, based on experience,
very small leaks are not an infrequent
occurrence.
A preceding period of at least one
hour without any water flow is neces-
sary so that a micro leakage test can
run.
Performing small leakage testing
automatically
Micro leakage testing can also be per-
formed automatically; in this case testing is
performed daily without anything further to
do.
The following setting is necessary for
this:
1. Press the menu key.
1703593 • 2022/10 JUDO JPCS 17

Operation
2. Select Setting using the arrow keys and
confirm with the OK key.
Main menue
• Setting
3. Select Leakage protect using the arrow
keys and confirm with the OK key.
Setting
Leakage protect
4. Select Auto. testing using the arrow
keys and confirm with the OK key.
Leakage protect
Auto. testing
5. Using the arrow keys select on or off, to
activate or deactivate automatic micro
leakage testing. Save the selected set-
ting with the OK key.
Auto. testing
• on
Auto. testing
• off
The selected setting is saved.
Possible settings for automatic micro leak-
age testing
The following settings can be selected
for the occurrence of a micro leakage
that has been detected via automatic
micro leakage testing:
•Micro leakage message on the display
•Micro leakage message on the display
and additional shutting off of the water
supply
1. Press the Main menue key.
2. Select Setting using the arrow keys and
confirm with the OK key.
Main menue
• Setting
3. Select Leakage protect using the arrow
keys and confirm with the OK key.
Setting
Leakage protect
4. Select Auto testing using the arrow
keys and confirm with the OK key.
Leakage protect
• Auto testing
5. Select Message only? using the arrow
keys and confirm with the OK key.
Auto testing
• Message only?
6. Select the desired setting using the
arrow keys and confirm with the OK
key:
Auto testing
Message only
Auto testing
Message+close
The selected setting is saved.
18 JUDO JPCS 1703593 • 2022/10

Operation
Starting micro leakage testing manu-
ally
Prerequisite: all water withdrawal points
must be closed during micro leakage test-
ing.
1. Press Menu key.
2. Select Leakage protection using the
arrow keys and confirm with the OK
key.
Main menue
• Leakage pro-
tect
3. Select micro leakage using the arrow
keys and confirm with the OK key.
Leakage protect
• Micro leakage
testing
Micro leakage testing starts.
If no micro leakage has been
detected, the display alternates
between
No leakage
occurred
To acknowledge
press <OK>
The display returns to the operating dis-
play.
If no micro leakage has been
detected, the display alternates
between
Small leakage
occurred
To acknowledge
press <OK>
The display returns to the operating dis-
play.
INFO_NO_HEADER
Micro leakage testing can be
started manually at any time
even when a regular automatic
test had been set.
Prerequisite for automatically
running micro leakage testing is a
period of
at least one hour, in which no
water withdrawal takes place.
4.4 Setting limit values
Exceeding of the set limit values for
•maximum water quantity
•maximum water flow
•maximum water withdrawal time
leads to shutting off of the water supply.
INFO_NO_HEADER
When setting the limit values, con-
sideration must be given to devices
that depend on a sometimes very low
continuous water supply over a long
period of time to ensure their proper
functioning (e.g. certain tumble dry-
ers, etc.).
It is also possible to operate such
devices using sleep mode of the
micro leakage protection system.
1703593 • 2022/10 JUDO JPCS 19

Operation
4.4.1 Factory setting
The table shows the factory set limit val-
ues at which the device shuts off the
water supply:
Shut-off criterion Value / unit
Maximum water quan-
tity
(uninterrupted)
500 litres (L)
Maximum water flow
(uninterrupted)
4000 litres per
hour (L/h)
Maximum water with-
drawal time
30 minutes
(min)
Table 1: Factory-set limit values
If desired, allow adjustment of the limit val-
ues in two different manners:
•Manual (see chapter 4.4.2)
•Via learning mode (see chapter 4.4.3).
4.4.2 Changing limit values manu-
ally
Procedure:
1. Press Menu key.
2. Navigate to Setting using the arrow
keys and confirm with the OK key.
3. Navigate to Leakage protection using
the arrow keys and confirm with the OK
key.
4. Navigate to Leakage protect/limit values
using the arrow keys and confirm with
the OK key.
Then the individual shut-off criteria can
be selected and set to the desired value
inside the ranges specified in the table
(select via arrow key, confirm with OK).
Shut-off
criterion
Setting
range
Step
size
Max. with-
drawn time
10 min to 10 h,
unlimited
10 min
Max. water
flow
500 to 5000 L/h,
unlimited
500 L/h
Max. water
quantity
100 to 3000 L,
unlimited
100 L
Table 2: Adjustment ranges of the limit val-
ues
4.4.3 Determine and set limit values
automatically: Learn mode
Reasonable limit value settings correspond-
ing to the individual water consumption are
calculated and saved from the factory limit
settings and the water withdrawals during
the first 10 m³ of water flow.
INFO_NO_HEADER
The learning mode phase is indicated
by L10 at the end of the second line
of the display.
The value after the L indicates how
many m³ water flow are still outstand-
ing before learning mode will be com-
plete.
Starting learning mode:
1. Press Menu key.
2. Navigate to learning mode using the
arrow keys and press OK key.
Learning mode starts
During learning mode, the following are
output to the display in alternation:
Learning mode
is terminated
20 JUDO JPCS 1703593 • 2022/10
This manual suits for next models
6
Table of contents
Popular Plumbing Product manuals by other brands

Signature Hardware
Signature Hardware Edenton 951180 manual

Spectrum Brands
Spectrum Brands Pfister McAllen LG42-MCA0 Quick installation guide

CANTERBURY
CANTERBURY Z2208--27 quick start guide

Tylo
Tylo Sauna i1309 manual

American Standard
American Standard Williamsburg 0554.700 Specification sheet

Moen
Moen ioDIGITAL T3490 Series manual

Viega
Viega Prevista Dry Instructions for use

KWC
KWC F4LT1015 Installation and operating instructions

Glacier bay
Glacier bay HDQFW6AC027CP Installation and care guide

Hans Grohe
Hans Grohe Ecostat E 15708 Series Instructions for use/assembly instructions

Hans Grohe
Hans Grohe Bodyvette Stop 28467000 Assembly instructions

Luxart
Luxart Selah SH341 installation manual