Kantech kt-100 User manual

Mini Door Controller
Opens the door to versatile security
KT-100
• Flash memory programming
• Fast Communication Speed up to 115,200 bauds
• Trouble Reporting
• Shorter Installation Time
• Interfaces with an External Alarm System
Item # 20950
DN1512-0412
© 2003 Kantech Systems. All rights reserved. Specifications may be modified without
notice. ™ Trademarks of Kantech Systems
Product specifications and availability subject to change without notice.
Certain product names mentioned herein may be trade names and/or
registered trademarks of other companies.
KT-100 Technical Specifications
Input power 9.5 to 14 VDC/50mA + accessories (Max. 750mA)
Battery backup 1 lithium battery, up to 10 year retention
Dimensions (H·W·D) inches 4.5” H x 2.75” W x 1.25” D (11.4cm x 7.0cm x 3cm)
Operating temperatures From 35°F to 110°F (2°C to 40°C), 0-95% humidity, non-condensing
Reader types Wiegand, proximity, bar code, magnetic, integrated keypad and others
Monitored points (inputs) 4 monitored points, NO/NC, with or without end-of-line resistors
Points maximum wiring 600m (2,000‘) – (AWG #22)
Door strike power 12VDC, 250mA each, supervised
Auxiliary outputs (LED, BUZ) 2 outputs, open NPN collector for door access & status
25mA max, 12 VDC each
Relay outputs (R1 ,R2 , R3 , R4) 2 control relay outputs, 12VDC, 25mA totals each, open collector
to ground
2 relay outputs, 30VAC/DC, 50mA (max) each. Two opto-isolated
contacts per relay
Reader power outputs 5VDC @150mA total, protected
Communication ports RS-485
Communication speed Up to 115,200 bps (automatic detection)
Firmware Flash memory 64k
RAM memory 128k, protected by a lithium battery
Network autonomy Distributed data and processing
Certifications/Listing FCC Part 15, Class B
Ordering Information
KT-100 Mini Door Controller 2 readers, 1 door
(requires 12VDC power supply)
MUSB-1WHT Surface mounting box to use with the KT-100
Mini Door Controller (color: white)
VC-485 RS-232/RS-485 multi-function
communication interface
USB-485 USB to RS-485 communication interface
Tel: 1-450-444-2040 Fax: 1-450-444-2029
Toll free: 1-888-KANTECH (1-888-526-8324)
http://www.kantech.com
Mini Door Controller
Opens the door to versatile security
KT-100
Flash Memory Programming
The KT-100’s firmware program is stored in flash memory
for easy upload from the workstation without changing
memory chips. Security providers will also find the flash
memory saves time by allowing system upgrades from a
PC without having to physically go to every controller.
Trouble Reporting
Constant trouble supervision keeps tabs on the unit’s
power supply and whether a short to ground or open
circuit is affecting the locking device. It also checks all the
equipment for any type of failure or tampering, while a
self-resetting PTC protects the power output against short
circuits and surges.
Shortens Installation Time
Mounts on the secure side of a door, reducing the length
of cable required for installations. Has no dipswitches or
jumpers to set. Includes connections for 2 card readers
(entry/exit), lock device, door contact and request to exit.
Mounting is easy: it can be placed on a single gang box
(flush mount) or on a surface back box specially
designed for it.
Interfaces With An External
Alarm System
Installers can assign registered users permission to arm or
disarm an external alarm system. Using a TCP/IP interface
module, the KT-100 can be connected to a LAN/WAN
network (using Kantech’s EntraPass Corporate Edition
multi-user access control system software).

Other manuals for kt-100

1

Other Kantech Network Card manuals

Kantech Expansion Modules Cabinet KT-MOD-CAB Assembly instructions

Kantech

Kantech Expansion Modules Cabinet KT-MOD-CAB Assembly instructions

Kantech KT-400 Expansion Module KT-MOD-INP16 User manual

Kantech

Kantech KT-400 Expansion Module KT-MOD-INP16 User manual

Kantech KT-200 User manual

Kantech

Kantech KT-200 User manual

Kantech Multi-function Communication Interface... Quick start guide

Kantech

Kantech Multi-function Communication Interface... Quick start guide

Popular Network Card manuals by other brands

Wyrestorm Enado instruction manual

Wyrestorm

Wyrestorm Enado instruction manual

Abus FUMO50040 Installation instructions and user manual

Abus

Abus FUMO50040 Installation instructions and user manual

HomeLink MPUW1801 user manual

HomeLink

HomeLink MPUW1801 user manual

Multitech RouteFinder RF802USB user guide

Multitech

Multitech RouteFinder RF802USB user guide

D-Link DHP-307AV user manual

D-Link

D-Link DHP-307AV user manual

TRENDnet 10/100 Mbps Ethernet Card PF-16 PCMCIA user manual

TRENDnet

TRENDnet 10/100 Mbps Ethernet Card PF-16 PCMCIA user manual

Sonnet Presto 10GbE SFP+ quick start guide

Sonnet

Sonnet Presto 10GbE SFP+ quick start guide

Asus USB-N13 user manual

Asus

Asus USB-N13 user manual

SMC Networks SMC9432TX user guide

SMC Networks

SMC Networks SMC9432TX user guide

Lancom AirLancer MC-54ag manual

Lancom

Lancom AirLancer MC-54ag manual

miniDSP WI-DG user manual

miniDSP

miniDSP WI-DG user manual

D-Link DGE-530T manual 

D-Link

D-Link DGE-530T manual 

StarTech.com ST2GPEX quick start guide

StarTech.com

StarTech.com ST2GPEX quick start guide

Eaton PXGMS Power Xpert Gateway Minislot UPS quick start guide

Eaton

Eaton PXGMS Power Xpert Gateway Minislot UPS quick start guide

Nortel Agent Greeting NTVQ09AB Maintenance and troubleshooting guide

Nortel

Nortel Agent Greeting NTVQ09AB Maintenance and troubleshooting guide

Freescale Semiconductor Microcontrollers manual

Freescale Semiconductor

Freescale Semiconductor Microcontrollers manual

Allied Telesis AT-2746FX datasheet

Allied Telesis

Allied Telesis AT-2746FX datasheet

Alcatel 7270 MSC Specifications

Alcatel

Alcatel 7270 MSC Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.