Minimum spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
[] Additional spacing should be considered for ease of installation and
servicing.
[] Additional clearances might be required for wall, door, and floor
moldings.
[] Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation openings in
the top and bottom of the door are required. Louvered doors with
equivalent ventilation openings are acceptable.
[] Companion appliance spacing should also be considered.
Minimum installation Spacing
14" max.
(356 ram) i-_
1t.--
(140 m m)'_x, "'i,
(25 ram)
1 18"
(457 mm)
(25 ram)
_Additional spacing is recommended.
3mm
(76 ram)
48 (n?
(310 cm2)
24 in.2
(155cm2)
(76 ram)
Mobile home = Additional installation requirements
This dryer is suitable for mobile home installations. The installation must
conform to the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
[] Metal exhaust system hardware, available for purchase. For further
information, please reference the "Assistance or Service" section of
your Use and Care Guide.
[] Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby window)
should be at least twice as large as the dryer exhaust opening.
Electrical Requirements
it is your responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved in
remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
[] To supply the required 3 or 4 wire, single phase, 120/240 volt, 60
Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specified on the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit.
Do not have a fuse in the neutral or grounding circuit.
[] Do not use an extension cord.
[] if codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of electrical
connection you will be using and follow the instructions provided for it
here.
[] if local codes do not permit the connection of a neutral ground wire
to the neutral wire, see "Optional 3-wire connection" section.
[] This dryer is manufactured ready to install with a 3-wire electrical
supply connection. The neutral ground wire is permanently connected
to the neutral conductor (white wire) within the dryer, if the dryer
is installed with a 4-wire electrical supply connection, the neutral
ground wire must be removed from the external ground connector
screw (green screw), and secured under the neutral terminal (center
or white wire) of the terminal block. When the neutral ground
wire is secured under the neutral terminal (center or white wire) of
the terminal block, the dryer cabinet is isolated from the neutral
conductor.
[] A 4-wire power supply connection must be used when the dryer is
installed in a location where grounding through the neutral conductor
is prohibited. Grounding through the neutral is prohibited for (1)
new branch-circuit installations, (2) mobile homes, (3) recreational
vehicles, and (4) areas where local codes prohibit grounding through
the neutral conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers.
The kit should contain:
[] A UL listed 30-amp power supply cord, rated 120/240 volt minimum.
The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m)
long. The wires that connect to the dryer must end in ring terminals
or spade terminals with upturned ends.
[] A UL listed strain relief.
6