Ningbo Kepo Electronics Co.,Ltd. http://www.chinaacoustic.com
4. Reliability Test
Aftertest(1~8item), the BuzzerS.P.L. differenceshall be within ±10dB,Frequency
differenceshall be within ±0.2KHz. and the appearancenot exist anychange tobe harmful
tonormaloperation(e.g. cracks,rusts,damagesand especially distortion).
ModelNo. :
Page
Revision No.
Drawing No.
4/10
在1-8项试验后,蜂鸣器的声压变化值在±10dB之内,频率变化在±
0.2KHZ之内。外观无变化(例如:开裂、生锈、损伤、变形等现象).
SpecificationforMagneticBuzzer
KPMB-G3008-4233 OEM4233R
1.1
Afterbeing worked inachamberat +60±2 for 1hour,
then soundershall be placed inachamberat -20±2for 1
hour(1cycleis the belowdiagram).
After6abovecycles, soundershall be measured afterbeing
placed innaturalcondition for1hour.
Afterbeing placed inachamberwith 90 to95%R.H.at +40±2
for2hand then being placed innaturalcondition for2h,
soundershall be measured.
First being worked inachamberwith -20±2for 2hand
then being placed inachamberwith -20±2 ℃for16h, finally
being placed innaturalcondtion for2h, soundershall be
measured.
Afterbeing woked inachamberwith +60±2for 2h and
then being placed innaturalcondition for2h, soundershall be
measured.
-20
+60
将产品置于+60±2 试验箱中,先工作 2小时,然后在正常
大气压条件下恢复2小时后,进行测量
将产品置于-20±2 试验箱中,先工作 2小时,再放置16小时,
然后在正常大气压条件下恢复 2小时后,进行测量
将产品置于湿度为90~95%R.H,温度为40±2℃试验箱中2小
时,然后在正常大气压条件下恢复 2小时后,进行测量
将产品置于60±2 ℃试验箱中,先工作1小时,然后将产品置于
-20±2 ℃试验箱中,再工作1小时,经过6个循环后,在正常大气
压条件下恢复1小时,进行测量
4ThermalShock
Test
热冲击试验
3
2
1
Item
LowTemperature
Test
High Temperature
Test
HumidityTest
湿试验
低温试验
高温试验
1hour
1hour
20 Sec.
Specification