Keysight N2763B User manual

Keysight N2763B
Rack Mount Kit for 4000G X-Series
Oscilloscopes
INSTALLATION GUIDE

Notices
© Keysight Technologies, Inc. 2012, 2023
No part of this manual may be reproduced in
any form or by any means (including elec-
tronic storage and retrieval or translation into
a foreign language) without prior agreement
and written consent from Keysight Technolo-
gies, Inc. as governed by United States and
international copyright laws.
Manual Part Number
N2763-97001
Edition
First Edition, October 2023
Printed in Malaysia
Published by:
Keysight Technologies, Inc.
1900 Garden of the Gods Road
Colorado Springs, CO 80907 USA
Warranty
The material contained in this document is
provided "as is," and is subject to being
changed, without notice, in future editions.
Further, to the maximum extent permitted
by applicable law, Keysight disclaims all
warranties, either express or implied, with
regard to this manual and any information
contained herein, including but not limited
to the implied warranties of merchantability
and fitness for a particular purpose.
Keysight shall not be liable for errors or for
incidental or consequential damages in
connection with the furnishing, use, or
performance of this document or of any
information contained herein. Should
Keysight and the user have a separate
written agreement with warranty terms
covering the material in this document that
conflict with these terms, the warranty
terms in the separate agreement shall
control.
Technology Licenses
The hardware and/or software described in
this document are furnished under a license
and may be used or copied only in
accordance with the terms of such license.
U.S. Government Rights
The Software is "commercial computer
software," as defined by Federal Acquisition
Regulation ("FAR") 2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of
Defense FAR Supplement ("DFARS")
227.7202, the U.S. government acquires
commercial computer software under the
same terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the Software
to U.S. government customers under its
standard commercial license, which is
embodied in its End User License Agreement
(EULA), a copy of which can be found at
www.keysight.com/find/sweula. The
license set forth in the EULA represents the
exclusive authority by which the U.S.
government may use, modify, distribute, or
disclose the Software. The EULA and the
license set forth therein, does not require or
permit, among other things, that Keysight: (1)
Furnish technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish to, or
otherwise provide, the government rights in
excess of these rights customarily provided
to the public to use, modify, reproduce,
release, perform, display, or disclose
commercial computer software or
commercial computer software
documentation. No additional government
requirements beyond those set forth in the
EULA shall apply, except to the extent that
those terms, rights, or licenses are explicitly
required from all providers of commercial
computer software pursuant to the FAR and
the DFARS and are set forth specifically in
writing elsewhere in the EULA. Keysight shall
be under no obligation to update, revise or
otherwise modify the Software. With respect
to any technical data as defined by FAR
2.101, pursuant to FAR 12.211 and 27.404.2
and DFARS 227.7102, the U.S. government
acquires no greater than Limited Rights as
defined in FAR 27.401 or DFAR 227.7103-5
(c), as applicable in any technical data.
Safety Notices
This product has been designed and tested in
accordance with accepted industry stan-
dards, and has been supplied in a safe condi-
tion. The documentation contains information
and warnings that must be followed by the
user to ensure safe operation and to maintain
the product in a safe condition.
CAUTION
A CAUTION notice denotes a hazard.
It calls attention to an operating
procedure, practice, or the like that,
if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTION notice until the indicated
conditions are fully understood and
met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated
conditions are fully understood and
met.
2 Rack Mount Kit for 4000G X-Series Oscilloscopes

Rack Mount Kit for 4000G X-Series Oscilloscopes 3
In This Guide…
This guide contains instructions for installing the Rack Mount Kit for
4000G X-Series Oscilloscopes. The Rack Mount Kit provides a support shelf and
hardware for mounting Keysight 4000G X-Series oscilloscopes into Electronic
Industries Association (EIA) standard 19-inch (487-mm) rack cabinets.
The Rack Mount Kit includes the following parts:
Quantity Part Number Description
1 N2763-68702 Tray, Rack Assembly
1 N2763-01201 Clamp, Top
2 N5470-03701 Rail, Rack Mount
2 N2763-24104 Trim Plate, Side
1 N2763-24106 Trim Plate, Top
1 N2763-68703 Trim Plate, Bottom Assembly
2 0515-0456 Screw, machine, pan head, with washer, Torx T20
M4 x 0.7, 20 mm
2 0515-2049 Screw, machine, flat head, Torx T20 M5 x 0.8,
16 mm
4 2360-0806 Screw, machine, pan head Philips, 10-32 x 0.5 in
12 0590-0804 Nut, sheet metal, 10-32 x 0.5
8 3030-1768 Screw, special, pan head, Philips, 10-32 x 0.625 in

4 Rack Mount Kit for 4000G X-Series Oscilloscopes
N5470-03701 Rack Mount Rail, Qty. 2
N2763-68702 Rack Tray Assembly
N2763-01201 Top Clamp

Rack Mount Kit for 4000G X-Series Oscilloscopes 5
N2763-68703 Bottom Trim Plate Assembly
N2763-24104 Side Trim Plate, Qty. 2
N2763-24106 Top Trim Plate

6 Rack Mount Kit for 4000G X-Series Oscilloscopes
3030-1768

Installation
Rack Mount Kit for 4000G X-Series Oscilloscopes 7
Installation
You will need the following tools to install the Rack Mount Kit:
• T20 Torx driver.
• #2 Phillips screwdriver.
To perform the installation:
1Set the oscilloscope on its back. Remove the T20 screw from each leg.
2Set the oscilloscope onto the N2763-68702 Rack Tray Assembly.
T20 screw

8 Rack Mount Kit for 4000G X-Series Oscilloscopes
Installation
3Secure the oscilloscope to the Rack Tray Assembly using (Qty. 2) 0515-0456
screws.
4Remove the oscilloscope’s strap handle using a Torx T20 driver.
0515-0456 screw
handle removed

Installation
Rack Mount Kit for 4000G X-Series Oscilloscopes 9
5Attach the N2763-01201 Top Clamp to the top of the oscilloscope using (Qty 2)
0515-2049 screws.
0515-2049 screws

10 Rack Mount Kit for 4000G X-Series Oscilloscopes
Installation
6Attach the two N5470-03701 Rack Mount Rails to your rack using (Qty. 4)
2360-0806 screws and (Qty. 4) 0590-0804 nuts.
Four
2360-0806 screws,
0590-0804 nuts

Installation
Rack Mount Kit for 4000G X-Series Oscilloscopes 11
7Slide the assembled oscilloscope and Rack Tray Assembly into the rack.
8Secure the two Side Trim Plates to the rack using (Qty. 4) 3030-1768 screws
and (Qty. 4) 0590-0804 nuts. Assembly may be easier if you slightly lift the
oscilloscope to align the holes.
Four
3030-1768 screws,
0590-0804 nuts

12 Rack Mount Kit for 4000G X-Series Oscilloscopes
Installation
9Secure the N5470-24102 Top Trim Plate to the rack using (Qty. 2) 3030-1768
screws and (Qty. 2) 0590-0804 nuts.
Two
3030-1768 screws,
0590-0804 nuts

Installation
Rack Mount Kit for 4000G X-Series Oscilloscopes 13
10 Bottom Trim Plate:
aOptional: If you plan to connect cables from the oscilloscope to the BNC
feedthroughs, connect them now. It may be difficult to connect them after
securing the bottom trim plate.
bOptional: If you plan to route the MSO cable through the notch in the Bottom
Trim Plate, route it now.
cSecure the N2763-68703 Bottom Trim Plate to the rack using (Qty. 2)
3030-1768 screws and (Qty. 2) 0590-0804 nuts.
11 Store the oscilloscope’s legs, strap handle, and related hardware in the zipper
pouch on the rear of the Rack Tray.
You have completed installation of the Rack Mount Kit.
Two
3030-1768 screws,
0590-0804 nuts
Route MSO
cable here
Zipper
Pouch

14 Rack Mount Kit for 4000G X-Series Oscilloscopes
Installation


This information is subject to change
without notice.
© Keysight Technologies, Inc. 2012,
2023
Printed in Malaysia
First Edition, October 2023
*N2763-97001*
N2763-97001
www.keysight.com
Table of contents
Other Keysight Rack & Stand manuals

Keysight
Keysight Y1217A Installation and operation manual

Keysight
Keysight MXR2RACK User manual

Keysight
Keysight EDU190A User manual

Keysight
Keysight Y1225A User manual

Keysight
Keysight Y1164A User manual

Keysight
Keysight Y1215B Quick start guide

Keysight
Keysight N2138A User manual

Keysight
Keysight E7590A User manual