manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kidde
  6. •
  7. Rack & Stand
  8. •
  9. Kidde SMK23 Assembly instructions

Kidde SMK23 Assembly instructions

SMK23 Pattress Surface Mount Pattress For models:
123I, 123/9HI, 123/9HILL, 123/9EI, 223I, 223/9I,
223/9ILL, 223/9HI, 223/9HILL, 323I, 323/9HI, 323/9HILL
Application
• This surface mount pattress is for use with
KIDDE Fyrnetics, Hard Wired Smoke, Heat and
CO Alarms, where surface cabling is being
used, such as in retrofit applications.
Usage
• This is designed for installation by a qualified
electrician, in accordance with the current IEE
regulations. Failure to install correctly can result
in a fatal shock or fire hazard.
• Alarms without battery back-up must be
connected direct to the Consumer Unit on a
separately fused spur – see current Building
Regulations.
(AC models with battery back-up may be
connected off an adjacent lighting circuit).
• Knock-outs on the underside and edge of the
pattress provide flexibility of cable entry, for
ease of use. A small rib on the edge of the
pattress lines up with a mark on the alarms
base plate, to ensure correct alignment.
• Site and select alarm type in accordance with
manufacturer literature/manual shipped with
alarm. Also refer to Building Regulation
requirements if applicable, plus BS5839 Pt 6.
• Isolate mains power before commencing work.
• Never remove/refit the cable harness whilst
mains power is present.
Surface Mounting Kit
Installer’s Guide
• Crossing line and neutral connections or line
and interconnect connections will fatally
damage all interconnected alarms invalidating
the guarantee.
• Never Meggar Test an installation, without
disconnecting any connected alarms (this can
permanently damage the alarm and invalidates
the guarantee).
• All interconnected alarms must be powered off
the same fuse/circuit breaker.
• Total cable length between alarms must not
exceed 250m (273yds) and be 1.5mm in
diameter, 3 core and earth (BS6243Y).
Important Notes
• As in illustration 1 (on reverse), bring mains
cabling into pattress terminal block via knock-
out selected and fix pattress to ceiling with
2 screws.
(If using dry lining box, select appropriate holes
on pattress and secure with machine screws.)
• Wire in mains cabling to terminal block, looping
“earth” in and out.
• Connect flying leads on alarm cable harness to
appropriate terminals and ensure polarity is
correct.
• Install and test alarm by following guidance in
Installer Manual of alarm.
smk23UM/800
KIDDE Safet Europe, Mathisen Wa , Colnbrook, SL3 0HB, UK.
© KIDDE Fyrnetics 2000
Blue
White*
Brown
Line (Red)
Earth
Neutral (Black)
Blue
White*
Brown Blue
White*
Brown
* Interconnect only –if single alarm installation, leave unconnected with sheathing intact.
Connect to Terminal Block in ceiling cavity or via Surface Pattress.
These are double insulated products and do not need earthing –
never use earth conductor to interconnect – use 3 core and earth (BS6243Y).
House Cabling
(Interconnect)*
1.
2.

Other Kidde Rack & Stand manuals

Kidde SMK23R Assembly instructions

Kidde

Kidde SMK23R Assembly instructions

Kidde SMK23RU Assembly instructions

Kidde

Kidde SMK23RU Assembly instructions

Kidde KI-ABST Assembly instructions

Kidde

Kidde KI-ABST Assembly instructions

Popular Rack & Stand manuals by other brands

Philips TC349815 instructions

Philips

Philips TC349815 instructions

New Star Computer Products FPMA-D965 instruction manual

New Star Computer Products

New Star Computer Products FPMA-D965 instruction manual

LEGRAND 6 531 10 quick guide

LEGRAND

LEGRAND 6 531 10 quick guide

Genelec 8260-450B instructions

Genelec

Genelec 8260-450B instructions

Perlesmith PSLFK1-24 installation instructions

Perlesmith

Perlesmith PSLFK1-24 installation instructions

Videotec UCCMA instruction manual

Videotec

Videotec UCCMA instruction manual

Epcom EPB64EW installation manual

Epcom

Epcom EPB64EW installation manual

Panasonic TY-S37PA50W instructions

Panasonic

Panasonic TY-S37PA50W instructions

CONNECTA HEF655 instruction manual

CONNECTA

CONNECTA HEF655 instruction manual

VonHaus 3000249 quick start guide

VonHaus

VonHaus 3000249 quick start guide

Elite Screens ZCVMAX99S user guide

Elite Screens

Elite Screens ZCVMAX99S user guide

FourStarGroup 11200471C quick start guide

FourStarGroup

FourStarGroup 11200471C quick start guide

Holman 40200 Instruction guide

Holman

Holman 40200 Instruction guide

Classic Exhibits SEGUE DESIGNS VK-1902 manual

Classic Exhibits

Classic Exhibits SEGUE DESIGNS VK-1902 manual

IBM Netfinity 5Ux24D Tower-to-Rack Kit installation instructions

IBM

IBM Netfinity 5Ux24D Tower-to-Rack Kit installation instructions

MANORGA EPSILON Assembly instructions

MANORGA

MANORGA EPSILON Assembly instructions

AMC Akustik EP Series installation instructions

AMC

AMC Akustik EP Series installation instructions

bouncepad Wing Assembly instructions

bouncepad

bouncepad Wing Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.