Safety Precautions Soft Good Kits
the regulator may cause free flow. This is easily
stopped by slightly blocking the main outlet port.
1. At a minimum, the regulator should be thor-
oughly rinsed with fresh clean water after every
dive. Install blue cap with O-ring onto hose end of
the regulator. Mild liquid dish soap can be used to
remove grime. Avoid harsh cleaners.
2. If possible, the entire regulator should be soaked
in fresh warm water, between 80–120 °F (26–49
°C), for 15 minutes or longer. Soaking in warm wa-
ter will remove salt and mineral deposits more ef-
fectively than a fresh water rinse alone.
3. Allow the regulator to dry completely before
storage. Do not leave the regulator sitting in direct
sunlight. Shake the second stage to help remove
water trapped inside.
BCAUTION
During soaking do not depress the
purge button on the second stage.
Pressing the purge button can al-
low water to enter the inlet valve and
possibly go into the critical balancing
chamber. Water inside the balancing
chamber will lead to improper regu-
lator function, which could result in
personal injury.
4. Turn the second stage regulator adjustment
knob all the way out, away from the second stage
body. This will help lengthen the life of the regula-
tor seat.
5. Ensure the regulator is completely dry before
storing. Store only in a clean, cool, dry place.
BCAUTION
Never store the regulator while still
connected to a SCUBA cylinder. Im-
proper care or storage of underwa-
ter breathing equipment may lead to
equipment malfunction, which could
result in personal injury.
BWARNING
DO NOT use cleaning solvents on any
parts or components of this regulator.
The use of solvents may lead to failure
of the regulator parts and regulator
malfunction, which could cause seri-
ous injury or death.
BCAUTION
NEVER pressurize the rst stage regu-
lator without having a second stage
attached. This can lead to a sudden
burst of high pressure air, causing the
hose(s) to whip about, which could
cause personal injury.
1.2.1 Soft Good Kits
Always refer to M-48 appendices for scheduled
maintenance. These can be located at the back
of the user guides as well as under the support
tab at KMDSI.com. While all individual parts in the
rebreather POD and switchover regulator assem-
blies can be ordered separately, KMDSI has also
created kits to be use used for periodic, annual
and when required service.
Guidelines
O-rings should be lightly lubricated with oxygen
compatible NON SILICONE lubricant ONLY, for
example, Christo-Lube®, Tribolube® or equivalent in
accordance with the operations and maintenance
manual. NEVER USE SILICONE based lubricants.
At a minimum all O-rings found in the switchover
Open Circuit Regulator should be replaced at least
once a year. Components might require replace-
ment more often than yearly if the assembly use
is extreme, or if used in waters containing oil or
chemical contamination. Daily cleaning and in-
spections as well as performing the monthly in-
spection will identify the need more accurately
than simply placing a number of hours between
overhaul. Store spare O-rings, valves and soft
goods in a cool, dark, dry place. Avoid prolonged
exposure to temperatures above 90 °F (32 °C)
and/or exposure to ultra violet rays. Do not lubri-
cate exhaust valves. Lubricating valves can cause
dirt to stick, allowing leakage.