GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• This product is Class II double insulated
• This product is IPX4 rated
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible.
• Provide power to the required point of installation
• Cut a suitable 100mm diameter hole in the mounting surface ensuring not to infringe with any joists,
gas / water pipes or electrical cables. Install suitable ducting and a suitable external grille or shutter. The
maximum length of ducting to be used is 2m
• Remove the front fascia (see Fig. 1)
EX003T / EX004T / EX005T
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
EX003T / EX004T / EX005T
SAFETY
•This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•Please isolate mains prior to installation or maintenance
•Check the total load on the circuit (including when this product is fitted) does not exceed the rating of
the circuit cable, fuse or circuit breaker
•Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•This product is Class II double insulated
•This product is IPX4 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible.
•Provide power to the required point of installation
•Cut a suitable 100mm diameter hole in the mounting surface ensuring not to infringe with any joists,
gas / water pipes or electrical cables. Install suitable ducting and a suitable external grille or shutter.
The maximum length of ducting to be used is 2m
•Remove the front fascia (see Fig. 1)
Fig. 1
•Remove the faceplate by removing the screw at the bottom of the product and lifting off
•Mark the location of the fixing holes and drill ensuring not to infringe with any gas / water pipes or
electrical cables
•Remove the cable knock-out on the baseplate and guide the mains cable through
•Fix the base to the mounting surface using the fixings provided
•Remove the terminal cover by removing the two screws (see Fig. 2)
IPX4
Fig. 1

3
• Remove the faceplate by removing the screw at the bottom of the product and lifting off
• Mark the location of the fixing holes and drill ensuring not to infringe with any gas / water pipes or electrical
cables
• Remove the cable knock-out on the baseplate and guide the mains cable through
• Fix the base to the mounting surface using the fixings provided
• Remove the terminal cover by removing the two screws (see Fig. 2)
• Carefully bring the wires into the terminal enclosure and ensuring correct polarity is observed, wire as
shown in Fig. 3
• Adjust the overrun timer with the aid of a small screwdriver. Turn anti-clockwise to reduce (to a minimum
of 2 minutes) and clockwise to increase (to a maximum of 30 minutes)
• Reassemble the terminal cover, faceplate and front fascia
• Switch on and check for correct operation
Fig. 2
Fig. 3
Fig. 2
•Carefully bring the wires into the terminal enclosure and ensuring correct polarity is observed, wire as
shown in Fig. 3
Fig. 3
•Adjust the overrun timer with the aid of a small screwdriver. Turn anti-clockwise to reduce (to a
minimum of 2 minutes) and clockwise to increase (to a maximum of 30 minutes)
•Reassemble the terminal cover, faceplate and front fascia
•Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
The LED lamps fitted in this product are non-replaceable. The product should be recycled in the correct manner
when it reaches the end of its life. Check local authorities for where facilities exist.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product.
This product is non-dimmable.
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of
purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
Fig. 2
•Carefully bring the wires into the terminal enclosure and ensuring correct polarity is observed, wire as
shown in Fig. 3
Fig. 3
•Adjust the overrun timer with the aid of a small screwdriver. Turn anti-clockwise to reduce (to a
minimum of 2 minutes) and clockwise to increase (to a maximum of 30 minutes)
•Reassemble the terminal cover, faceplate and front fascia
•Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
The LED lamps fitted in this product are non-replaceable. The product should be recycled in the correct manner
when it reaches the end of its life. Check local authorities for where facilities exist.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product.
This product is non-dimmable.
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of
purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.

4
ML Accessories Limited
LU5 4LT
www.mlaccessories.co.uk DCFEB20_V1
ACCESSORIES LTD ACCESSORIES LTD
ACCESSORIES LTD
ACCESSORIES LTD
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
The LED lamps fitted in this product are non-replaceable. The product should be recycled in the correct
manner when it reaches the end of its life. Check local authorities for where facilities exist.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product.
This product is non-dimmable.
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance
with the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch
code will invalidate the warranty. If this product should fail within its warranty period, it should be returned
to the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility for
any installation costs associated with the replacement product. Your statutory rights are not affected.
ML Accessories reserve the right to alter product specification without prior notice.
This manual suits for next models
2
Table of contents
Other Knightsbridge Fan manuals
Popular Fan manuals by other brands

Americ Corporation
Americ Corporation VAF-3000 owner's manual

Harbor Breeze
Harbor Breeze 52 IN CLASSIC STYLE 40081 installation guide

Vents-us
Vents-us VKM 100 E user manual

Sabiana
Sabiana Ventil Carisma Fly CVP-ECM manual

Velleman
Velleman Perel CFANUSBD3 user manual

Honeywell
Honeywell Turbo Force HYF500 Series owner's manual