Konfor SPS-913BW User manual

Ultrasonic Mist Humidifier
User Manual
KONFOR
SPS-913BW

* Read all the safety instructions carefully before use and
keep this instruction manual for future reference:
Warning: Please be aware of the following points or you
might be in danger of high voltage charges or burn your
body.
1)Never disassemble the base unit without
consulting qualified personnel.
2)If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
3)Do not add detergents, chemical solutions which are not
made by our company into the unit.
4)Unplug appliance during filling, cleaning and
maintenance.
5)Keep detergents and chemical solutions away
from children.
6)Do not change attachment without definitive
permission from our company otherwise you
might cause a hazard.
7)If any abnormal smell during normal operation,
please switch off and disconnect power supply and
have qualified personnel amend.
8)If when cleaning with water, detergents &
chemical solutions splash into mouth & eyes,
consult a doctor to refrain from serious hazard.
9)Ne v e r to u ch wa t er i n the w a te r b asi n &
components in the water when the unit is in function.
10)Never switch on when there is no water in the water
basin.

11)Never scrape Transducer cpl on your own.
12)Never clean Transducer cpl with detergents or chemical
solutions that are not made by our company.
13)Never let water splash into inner base unit to avoid
components damage.
14)Care should be taken when using the appliance due to
emission of hot water vapor.
15)Before cleaning and maintenance, the appliance must be
disconnected from the power supply.
16)Prior to cleaning or other maintenance the appliance
must be disconnected from the supply mains.
17)This appliance can be used by children aged from 8 years
and above if they have been given supervision or
instruction concerning use of the appliance in a safe way
and if they understand the hazards involved. Cleaning
and user maintenance shall not be made by children
unless they are older than 8 and supervised. Keep the
appliance and its cord out of reach of children aged less
than 8 years. Cleaning and user maintenance shall not be
made by children without supervision.
18)Children should be supervised to ensure that they do not
play with the appliance.
19)Indoor use only.
,

*Working Principle: Ultrasonic Humidifier uses the ultrasonic
high-frequency oscillator to break up water into tiny water
particles with the diameter of about 1-5um.The ventilation
system blows out this water into the dry air where they
evaporate to give the required humidity. The clearly visible
smooth and even fog can be seen out of the unit.
*Features:
High efficient in humidification with large output.
Low energy consumption, save 85-90 percent of
electricity than normal stream humidifier.
Long lifetime
Automatic control of humidity level, lack-of-water
security protection.
Heating Function: Touch the Heating symbol to make
warm mist. Press again to stop the heating function.
Plasma: Touch the Plasma symbol of Plasma to spread
a number of Plasma elements. Press again to stop the
Plasma function.
Base with tray for the felt, to wet it with aromatic oil.

*Correct Humidity Level:
What exactly is relative humidity: Relative humidity is the
amount of water vapor in the air, expressed as a percentage of the
maximum amount that the air could hold at the given temperature..
We normally mark it with %RH, like 45%RH. Atomosphereic air
always contains water vapor, the percentage of which depends on
the meterological conditions. The higher the temperature is the
more the air keeps water vapor. Therefore, we use the concept of
‘relative humidity”. When the cold air is heated up to the comfort
temperature in winter, the relative percentage of the water vapor
falls which means the relative humidity drops. In order to keep a
comfortable and health environment at home, we need some
artificial addition of water or water vapor to the room air- that’s
air humidification.
Ideal relative humidity levels under different situations.
The most comfortable RH for human being 45-65%RH
Ideal RH for prophylactic and curative purpose: 40-55%RH
Computer and telecom apparatuses: 45-60%RH
Furniture and musical instruments: 40-60%RH
Library art gallery and museums: 40-60%RH

2. Fill the water into the water tank, and then tighten the tank cover. 1. Put the machine on a flat surface.
3. Put the water tank on the main
base.
*Operation Instruction
First Operation, put unit in the room temperature for half of
an hour before running.
It is recommended to use the unit under temperature of 20
degree C, relative humidity less than 80%RH. Use clear water not
over 40 degree C Check the water basin, make sure it is clear.

* FUNCTIONS
1: Relative Humidity
1. The percentage of water mist in a given space with a given
air temperature is named as relative humidity, usually marked
as %RH, i.e. 45%RH. The air contains water mist more or less.
The proportion of water mist to the air varies according to
different air temperatures. The higher the temperature, the
more water mist inhaled in the air.
2. In the winter, the cold air outside enters the room and
becomes warmer by the higher temperature in the room. As a
result, the relative humidity decreases. If you want to keep the
healthy environmental humidity, we need to increase the mist
volume in the air. The humidifier can do that for us.
3. Relative humidity in different environments suitable for
people:
Bedroom, living room: 45-64%RH
Patient’s room: 40-55RH
Room with computer, experiment equipments: 45-60%RH
Room with piano: 40-60%RH
Museum, exhibition hall, and library: 40-50%RH
2: Water filter:
1.Cation exchange resin filter can soften the hard water.
2.Cation exchange resin filter demineralize in the water.

INSTRUCTIONS FOR USAGE:
1.Put the machine on a flat surface.
2.Fill the water into the water tank, and then tighten the tank
cover.
3.Put the water tank on the main base.
4.Check if the rated voltage meets the input voltage, and
plug into the socket. Then display shows the symbol
POWER
5.Touch the symbol POWER on the machine, the
background LED light will be on. The machine will begin
to work in AUTO mode. Display shows AUTO symbol
and current humidity, temperature. After 15 seconds
without any operation, the display will become dim, press
any key except power key to wake up the display.
In Auto mode, the device determines the optimal humidity
by the formula and starts to achieve it at maximum power.
When the current humidity less than the table
showed humidity, it is in high speed operation.
When the humidity arrived, the machine will be in
low speed operation.
Temperatureof the air,
degreesCelsius Humidity,%
≤19 65
20 60
21 58
22 57
23 55
24 53
25 50
26 48
27 45
28 43
29 40
30 38
31 36
32 35
33 34
34 32
35 31
36 30
37 and higher 25

The device checks the accordance of the temperature
level and the humidity level every 1 minute.
6.
baby mode and auto mode
In health mode:
a) WARM MIST is on. Display show the health mode
symbol , warm mist symbol The device starts
to achieve humidity 60% at maximum power.
b) After the humidity 60% is achieved, the device
works at minimal power.
c) Only TIMER SETING function is operable in healthy
mode.
d) The device checks the humidity level every 1 minute
In baby mode:
a) WARM MIST and PLASMA functions are on also.
Display show the baby mode symbol , warm mist
symbol and plasma symbol . The device starts
to achieve humidity 55% at maximum power.
b) After the humidity 55% is achieved, the device
works at minimal power.
c) Only TIMER SETING function is operable in baby
mode.
d) The device checks the humidity level every 1 minute.
7. Touch the symbol LIGHT , it enters to night mode.
Water tank indication light and LED display turns off.
After 5 seconds without any operation, the display turns
off, leaving the symbol on the display only. Press
any key except power key to wake up the display. Touch
the symbol LIGHT again to stop the function.
8. Constant humidity: Before you touch the symbol
HUMIDITY , LED display shows the current
humidity. You may set the humidity arranged from
30%RH to 75%RH. Touch once, the current setting
mode is cancelled, it will increase by 5%RH. When it
reaches 75%RH, touch again, it will show “--” and flash
for 5 seconds to exit humidity setting function. After
Touch the symbol MODES , to choose health mode,

you set the expected humidity, the machine will keep
the memory and confirm after 5 seconds. The LED
display shows the symbol and current humidity.
Touch again, it shows the expected humidity setting.
If the expected humidity is less than the current
humidity, the machine will be in sleeping state. But if
the expected humidity is 3% higher than the current
humidity, the humidify function will work. Mist
output speed cannot be setting during the constant
humidity model.
9 . Ti m e r s e t t i n g : T h e r e a r e 1 2 t i m e r s e t t i n g :
1,2,3,4,5,6,7,8,9,10,11,12 hours. Touch the symbol
TIMER , the LED display will show the desired
setting timer. Touch till “--” display on the LED, timer
setting is cancelled. The timer shows the rest
operation time and decreases by 1 hours, i.e., if the
timer is set at 12 hours, LED display shows 11 after
one hour. Display shows current temperature and rest
operation time alternately in 30 seconds. To know
what time have been set, just to touch TIMER symbol.
Touch again, to set timer again.
10. Touch the symbol DEGERMING , the warm mist
will come out after 10~15 minutes. On the LED
display, it shows the symbol . Touch again, the
Plasma generator works as well. On the LED display, it
shows the shape .To u c h aga i n to s t o p the
related functions.
11.Mist output control from level low 1 to high level
7: When under Auto mode, baby mode or healthy
mode, slip to exit the mode, slip left to reduce
mist output, slip right to increase.
12.Auto Shut-Off: Once the water in the basin is too little
to keep the machine working, the machine will
automatically stop working. LED shows the shape of
lack of water . Refill the water, and the machine
will restart. If don’t refill water within 15 minutes, the
machine will automatically power off.
13.On the remote controller, the related symbol controls
the corresponding function.
14.No matter in any working mode, if no any operation in
about 15 seconds, the display will turn dim.

• Take the water tank out of the unit, open the water tank cover and fill the tank with clear water. Close
the cover and put the tank onto the base unit carefully.
• Put the nozzle into the socket on top of the water tank.
• Connect the power supply, switch on the unit (NEVER RUN THE UNIT WHEN THERE IS NO WATER IN
WATER BASIN), the main connection lamp will on. The unit will begin working.
Operation steps
Connect To The Mobile Client ——Quick Connect mode
1. Configure the network. 2. Scan the QR code below to download
the APP, or search for “ProscenicHome"
in the APP store to download the APP.
3. In the power-on state, long press
the key “ ” 3 seconds until the
WiFi indicator “ ” flashes quickly.
Add device
Add device
Add device
Confirmation indicator
5. erform network configuration.
According to the APP page prompt, select and enter the WiFi password to
make the device enter the connection state and wait for the distribution
network to complete.
* Note: the host does not support 5.8g band WiFi network.
confirm
Change network
4. APP add device: turn on the APP,
select add humidifier device and
confirm WiFi indicator “ ” flash.
Connect To Mobile Client

Connect to the mobile client ——Hotspot Mode
1. Connect your phone to WiFi, scan the QR code
below, or search for “ProscenicHome” in the app store
to download the app.
2. In the power-on state, long press the key “ ” 66
seconds until the WiFi indicator “ ” Slow flash.
Connect To Mobile Client & Parameters
3. Add a humidifier device to the app, switch to the hotspot mode, and
confirm that the WiFi indicator is in a slow flashing state.
4. According to the prompt of the
APP interface, select WiFi and enter
the password.
807C
LDS-xxxx
M7
H500
H600
Please select the purchased device
Click or pull up to load more
Please select the p
807C
......
......
indicator flashes slowly
Add a Device AP mode
make sure the WiFi indicator flashes slowly
Add a Device AP mode
make sure the WiFi indicator flashes slowly
5. According to the APP interface prompt, turn on“Phone Settings - Wireless LAN(WiFi)”, select “Proscenic-xxxx”
network connection and return to APP. Perform network configuration and wait for the distribution network to
complete.
* Note: the host does not support 5.8g band WiFi network.
Setting
AVAILABLENETWORKS
WLAN
WLAN
807C
XXXXXXXX
XXXXXXXX
Setting
AVAILABLE NETWORKS
WLAN
WLAN
807C
XXXXXXXX
XXXXXXXX
Network Configuration
SmartLife-XXXX
807C
Device Choice
Cancel Refresh
SmartLife-XXXX
807C
Device Choice
Cancel Refresh

Maintenance Instruction
In a case when the water is hard which means water contains too much calcium and magnesium, it can
cause a “white powder” problem and leave heavy scales on the surface of water basin, transducer and
inner surface of the water tank. Scales on the surface of transducer will let the unit work improperly.
Maintenance
1). Use cold boiled water or distilled water.
2). Clean the transducer, water tank and basin unit every week.
3) .Change the water in water tank more often to keep it fresh.
4) .Make sure to pull out the water from the water tank and dry the water basin before you store the unit
unused for a long period of time.
5).Clean the whole unit and make sure that all parts of the unit are dried completely before unused for
longer period of time.
We recommend
1). Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes.
2). Brush off the scale from the surface.
3). Rinse the transducer with clean water.
How to clean the transducer
1). Clean the water basin with soft cloth and the cleaning abluent if there is scale in it.
2). If the scale is covered on the security switch, drop the cleaning abluent on the scale and clean it out
with the brush.
3). Rinse the water basin with clean water.
How to clean the basin unit
• Model: SPS-913BW
• Power supply: 110-120V 50/60Hz
• Heating power: 80W
• Humidify power: 30W
• Total power: 110W
• Water tank capacity: 5L
• Evaporation Rate: ≥300mL/h
• Noise level: ≤35dB(A)
TECHNICAL DATA

Trouble Shooting Guide
10
If any trouble is found in normal operation, please kindly refer to the following points:
Trouble Shooting Guide
Do not dispose this product as unsorted municipal waste, collection of such waste separately for
special treatment is necessary.
DISPOSAL
Trouble Possible reasons Solution
Power lamp off, does not work No power supply Connect power supply, switch on
Power lamp on, no mist outlet
with wind
Abnormal smell mist 1. New unit
2. Dirty water or water sitting too long
1. Take out water tank, open cover,
let it stay 12 hours in cool position
2. Clean water tank, fill with clear water
1. No water in water tank
2. Security switch is too loose
1. Fill water into water tank
2. Tighten the switch
Power lamp on, unit doesn’t work Too much water in the water basin
Pull out same water from the water
basin, close the cover of water tank
tightly
Mist fog is too low
1. Too much scale in the water basin
2. Water is too dirty or water kept too
long in the tank
1. Clean transducer
2. Clean water tank, change to fresh
clear water
Abnormal noise
1. Resonant in water tank when
water is too low
2. Unit is on a unstable surface
1. Fill water into water tank
2. Move the unit to a stable flat surface
Mist fog coming out from around
nozzle
There are apertures between the
nozzle and water tank
Dip the nozzle in water for a while
and then fix it to the socket on
water tank

KONFOR Foshan Samyoo Electronic Co.,Ltd
Add : Jiangcun Industrial Zone ,Leliu ,Shunde
Foshan, Gugnagdong , P.R.China
Tel :0757-28601700
Fax :0757-28601711

FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving an tenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
Table of contents
Other Konfor Humidifier manuals
Popular Humidifier manuals by other brands

Condair
Condair HumiLife RH Series Operation manual

GeneralAire
GeneralAire Elite 570 Installation & owner's manual

Aprilaire
Aprilaire 400 Series owner's manual

Scarlett
Scarlett comfort SC-AH986M18 instruction manual

Vitek
Vitek VT-1761 Manual instruction

DriSteem
DriSteem XTR Installation, operation and maintenance manual