l-com AL-CAT5W-4 User manual

www.L-com.com
OUTDOOR INSTALLATION WARNING
IMPORTANT SAFETY PRECAUTIONS:
LIVES MAY BE AT RISK!Carefully observe these instructions and any special instructions that are included with the equipment you are installing.
IMPORTANT:Look over the site before beginning any installation, and anticipate possible hazards, especially these:
CONTACTING POWER LINES CAN BE LETHAL.Make sure no power lines are anywhere where possible contact
can be made. Antennas, masts, towers, guy wires or cables may lean or fall and contact these lines. People may be injured or
killed if they are touching or holding any part of equipment when it contacts electric lines. Make sure there is NO possibility
that equipment or personnel can come in contact directly or indirectly with power lines.
Assume all overhead lines are power lines.
The horizontal distance from a tower, mast or antenna to the nearest power line should be at least twice the total length of the
mast/antenna combination. This will ensure that the mast will not contact power if it falls either during installation or later.
TO AVOID FALLING, USE SAFE PROCEDURES WHEN WORKING AT HEIGHTS ABOVE GROUND.
• Select equipment locations that will allow safe, simple equipment installation.
• Don’t work alone. A friend or co-worker can save your life if an accident happens.
• Use approved non-conducting ladders and other safety equipment. Make sure all equipment is in good repair.
• If a tower or mast begins falling, don’t attempt to catch it. Stand back and let it fall.
• If anything such as a wire or mast does come in contact with a power line, DON’T TOUCH IT OR ATTEMPT TO MOVE IT. Instead, save your life by
calling the power company.
• Don’t attempt to erect antennas or towers on windy days.
MAKE SURE ALL TOWERS AND MASTS ARE SECURELY GROUNDED, AND ELECTRICAL CABLES CONNECTED TO ANTENNAS
HAVE LIGHTNING ARRESTORS. This will help prevent fire damage or human injury in case of lightning, static build-up, or short circuit within equipment
connected to the antenna.
IF A PERSON COMES IN CONTACT WITH ELECTRICAL POWER, AND CANNOT MOVE:
Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.
• The base of the antenna mast or tower must be connected directly to the building protective ground or to one or more approved grounding rods, using 1 O AWG
ground wire and corrosion-resistant connectors.
• Refer to the National Electrical Code for grounding details.
• Lightning arrestors for antenna feed coaxial cables are available from HyperLink Technologies, Inc.
• DON’T TOUCH THAT PERSON, OR YOU MAY BE ELECTROCUTED.
• Use a non-conductive dry board, stick or rope to push or drag them so they no longer are in contact with electrical power.
• Once they are no longer contacting electrical power, administer CPR if you are certified, and make sure that emergency medical aid has been requested.
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455

www.L-com.com
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455
To Ground
Note:
This unit provides Bi-Directional protection,
input and output cables may be interchanged.
AL-CAT5W-4 Connection Diagram
Terminated
CAT5 Cables
Terminated
CAT5 Cables RJ-45 Jacks
RJ-45 Jacks
IP-00113 Rev. A – 04/11 Page 2/1 Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.

www.L-com.com
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455
1. Position the suppressor with the cable glands
facing to the sides when mounting.
2. Install the the data cables through cable glands.
(note, un-booted RJ45 plugs will pass through
cable glands). Attach data cables to RJ45 Jacks
inside suppressor.
CAT5 Pinouts: 1 - Data 1 +
2 - Date 1 -
3 - Data 2 +
6 - Data 2 -
4 - DC 1
5 - DC 1
7 - DC 2
8 - DC 2
3. Adjust the cable inside of the unit to ensure proper
closing of the cover, then secure by tightening cable
glands onto cables.
4. Attach cover using the provided hardware.
5. To ensure proper operation of suppressor, install
an earth ground to the external ground lug on the unit.
EARTH GROUND
LINE
1
2
3
4
5
6
7
8
LINE
58 VOLT
PROTECTION
DEVICE
1
2
3
4
5
6
7
8
RJ45
RJ45
(SINGLE CHANNEL SHOWN)
AL-CAT5W-4 Installation Instructions
IP-00113 Rev. A - 04/11 Page 3/5

www.L-com.com
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455
AIP-00113 Rev. A – 04/11 Page 4/5
CAT5 Cable Reference
DATA PAIR 1 +
DATA PAIR 1 -
DATA PAIR 2 +
DATA PAIR 2 -
DC 1
DC 1
DC 2
DC 2
DATA PAIR 1 +
DATA PAIR 1 -
DATA PAIR 2 +
DATA PAIR 2 -
DC 1
DC 1
DC 2
DC 2
RJ45 Pin/Color RJ45 Pin/Color
LINE EQUIPMENT
AL-CAT5W-4 Lightning Protector
CAT5 (EIA 568-B) Cable
DATA PAIR 1 +
DATA PAIR 1 -
DATA PAIR 2 +
DATA PAIR 2 -
DC 1
DC 1
DC 2
DC 2
DATA PAIR 1 +
DATA PAIR 1 -
DATA PAIR 2 +
DATA PAIR 2 -
DC 1
DC 1
DC 2
DC 2
RJ45 Pin/Color RJ45 Pin/Color
LINE EQUIPMENT
AL-CAT5W-4 Lightning Protector
CAT5 (EIA 568-A) Cable
1 WHT/ORG
2 ORG
3 WHT/GRN
6 GRN
5 WHT/BLU
4 BLU
7 WHT/BRN
8 BRN
1 WHT/GRN
2 GRN
3 WHT/ORG
6 ORG
5 WHT/BLU
4 BLU
7 WHT/BRN
8 BRN
1 WHT/ORG
2 ORG
3 WHT/GRN
6 GRN
5 WHT/BLU
4 BLU
7 WHT/BRN
8 BRN
1 WHT/GRN
2 GRN
3 WHT/ORG
6 ORG
5 WHT/BLU
4 BLU
7 WHT/BRN
8 BRN
Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.

www.L-com.com
L-com Global Connectivity | 50 High St., West Mill, 3rd floor, Suite #30 | North Andover, MA 01845 | USA
© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com Logo are registered marks.
Toll Free Ordering and Technical Support: 1-800-343-1455
IP-00113 Rev. A – 04/11 Page 5/5
AL-CAT5W-4 Dimensions
LID SCREW (4X)
MOUNTING SCREW (4X)
(#6 OR M3.5 PAN HEAD)
CABLE
CONDUIT
(8X)
LID REMOVED FOR CLARITY
188.20
7.410
199.8
7.87
149.95.90
1194.685
99.13.90
8.25 209.6
6.46
4.79 121.6
75.8
26.71.05
2.99
1.15 29.2
1.41
3.09 78.4
164.1
35.9
0.69 17.6
GROUND LUG
Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.