Lütze LCOS Series User manual

Operating Instructions
LCOS Unmanaged Switch
4 ports / 8 ports
779200.0401, LCOS-SW-4P
779201.0401, LCOS-SW-4P
779200.0801, LCOS-SW-8P
779201.0801, LCOS-SW-8P
Version 01
2020-06-22

Friedrich Lütze GmbH
Postfach 1224 (PLZ 71366)
Bruckwiesenstrasse 17-19
D-71384 Weinstadt
GERMANY / DEUTSCHLAND
Tel.: +49 (0) 7151 6053-0
Fax: +49 (0) 7151 6053-277(-288)
www.luetze.com
The company Friedrich Lütze GmbH reserves the right to make changes to its products in the interest
of technical development. These changes are not necessarily documented in each individual case.
This manual and the information contained herein have been compiled with due care. However, the
company Friedrich Lütze GmbH accepts no liability for printing or other errors or resulting damage.
The brands and product names mentioned in this book are trademarks or registered trademarks of the
respective titleholders.
© Copyright 2018 by Friedrich Lütze GmbH. All rights reserved.

LCOS Unmanaged Switch ▪ Contents
1
TRANSPORTATION
Contents
1 Introduction....................................................................................................... 4
1.1 About these instructions .............................................................................................................. 5
2 General Information.......................................................................................... 6
2.1 Safety instructions and technical information .............................................................................. 6
2.2 Copyright ..................................................................................................................................... 6
2.3 Disclaim of Liability ...................................................................................................................... 6
2.4 Standards and norms .................................................................................................................. 7
2.5 Scope of validity of the manual.................................................................................................... 8
2.6 Approvals..................................................................................................................................... 9
2.7 Applicable documents................................................................................................................ 11
3 Safety ............................................................................................................... 12
3.1 Contents of the operating instructions ....................................................................................... 12
3.2 Applicable documents................................................................................................................ 12
3.3 Appropriate Use......................................................................................................................... 12
3.4 Product life................................................................................................................................. 13
3.5 Addressees................................................................................................................................ 14
3.6 Responsibility of the operator .................................................................................................... 15
3.7 Changes and modifications to the devices ................................................................................ 15
3.8 Safety device ............................................................................................................................. 15
3.9 Special safety notes................................................................................................................... 15
3.10 Further safety notes .................................................................................................................. 17
4 Product Overview ........................................................................................... 18
4.1 Construction types ..................................................................................................................... 18
4.2 Overview of product features..................................................................................................... 19
4.3 Function carrier (with power module) ........................................................................................ 21
5 Transport and storage.................................................................................... 22
6 Scope of delivery ............................................................................................ 23
6.1 The LCOS Unmanaged Switch consists of:............................................................................... 23
6.2 Accessories ............................................................................................................................. 23
6.3 Checking the delivery ................................................................................................................ 24
7 Product Assembly .......................................................................................... 25
7.1 LCOS Unmanaged Ethernet-Switches ...................................................................................... 25
7.2 LED status displays ................................................................................................................... 26
8 Technical Data ................................................................................................ 27
8.1 Identification............................................................................................................................... 27
8.2 Description................................................................................................................................. 27
9 Mounting / Dismounting................................................................................. 28
9.1 Installation position .................................................................................................................... 28
9.2 Mounting .................................................................................................................................... 29
9.3 Wiring......................................................................................................................................... 35
9.4 Pin assignment .......................................................................................................................... 36
9.5 Further information on the LCOS system (basics)..................................................................... 37
9.6 Coding of LCOS modules .......................................................................................................... 38
9.7 Installing Data and Power Bridges............................................................................................. 39
10 Commissioning - Hardware .......................................................................... 40
10.1 Safety notes Power supply ................................................................................................. 40
10.2 Safety notes Housing................................................................................................................. 41
11 Operation......................................................................................................... 42

LCOS Unmanaged Switch ▪ Contents
2
TRANSPORTATION
11.1 Functional description................................................................................................................ 42
11.2 Frame-Switching functionalities ................................................................................................. 42
11.3 Specific functions of the Ethernet interface ............................................................................... 43
11.4 Other functions and features ..................................................................................................... 43
11.5 Display elements ....................................................................................................................... 43
11.6 Interfaces ................................................................................................................................... 44
12 Maintenance Hardware................................................................................... 45
13 Final Shutdown and Disposal........................................................................ 46
14 Service ............................................................................................................. 47
15 Appendix ......................................................................................................... 48
15.1 Overview of other applicable documents................................................................................... 48
15.2 Explanation of abbreviations used............................................................................................. 49
16 Revision history.............................................................................................. 51

LCOS Unmanaged Switch ▪ Introduction
4
TRANSPORTATION
1 Introduction
These operating instructions are part of the LCOS Unmanaged Switch.
Before using the device, please read these operating instructions to avoid
possible dangers and to ensure proper use.
Short description LCOS Unmanaged (Industrial Ethernet) Switches
The LCOS unmanaged switches are highly suitable for use in industrial ethernet
networks. In addition to durability, the units also offer more performance, such as
QoS (Quality of services) or operation in Profinet and Ethernet IP. Thanks to their
modular design, the units can be supplied with power in the LCOS system either
by means of the existing connectors or via the power bus (PB). They can also be
used in building automation systems due to the fact that they can run on AC
voltage. The application temperature range is -25 °C to +70°C.
Read and understand these instructions before installing, operating, or
maintaining the equipment.
Risk of injury and damage to property due to non-observance of the
operating instructions.
Always read these operating instructions before planning the system in order
to avoid or reduce risks and damage.
These operating instructions contain important information on safety,
commissioning, operation, maintenance and disposal of the device.
Always keep the document at hand. This applies until the device is disposed of.
Pass on the operating instructions if the device is sold, distributed or loaned.
You can also find these operating instructions at www.luetze.com.
In the search field, enter either the product name: LCOS Unmanaged Switch
or the product number: 77920*

LCOS Unmanaged Switch ▪ Introduction
5
TRANSPORTATION
1.1 About these instructions
These operating instructions provide information on the handling of the LCOS
Unmanaged Switch over its entire product life cycle, from delivery to disposal.
Other documents apply in addition to these operating instructions. (See also
chapter „2.7 Applicable documents“ on page 11) in this document. Please
also refer to the data sheets associated with the products.
If you have suggestions for improving this document, please contact the company
Friedrich Lütze GmbH.

LCOS Unmanaged Switch ▪ General Information
6
TRANSPORTATION
2 General Information
2.1 Safety instructions and technical information
This document contains several safety messages. Each safety message contains
a defined signal word and a color. The color and the word are referring to an alert
level. There are 4 levels. The safety messages point out hazardous situations and
give information on how to avoid these.
Additionally following symbols can be found. These refer to important technical
information and instructions:
2.2 Copyright
This document is intended for the operator and his employees. It is forbidden to
give the content to a third party, to duplicate, exploit or impart it. The Friedrich
Lütze GmbH has to allow it explicit in writing.
General data, text, images and drawings are copyrighted and are liable to the
industrial property right. Contravention can be prosecuted. The named brands
and product names in this document are trademarks or registered trademarks by
titleholder.
2.3 Disclaim of Liability
The document was written under consideration of the applied standards,
regulations and the current state of technology.
The content is verified of accuracy. Discrepancies are not excluded. For those
discrepancies we disclaim liability. Applicable changes and additional information
will be in the next version of the document.
The Friedrich Lütze GmbH does not assume liability for any damages and
accidents of following reasons:
Indicates a hazardous situation, which if not avoided will result in death
or serious injury.
Indicates a hazardous situation, which if not avoided can result in death
or serious injury.
Indicates a hazardous situation, which if not avoided can result in minor
or moderate injury.
Indicates a situation which could damage the product or the environment.
This notice does not apply to personal injury.
Refers to important technical information.
This indicates to the user a specific action that must be performed to
operate the device safely.
Refers to the use of different tools.

LCOS Unmanaged Switch ▪ General Information
7
TRANSPORTATION
▪ Nonobservance of the document
▪ Untrained and unqualified personnel
▪ Non conventional use
▪ Non approved reconstructions and functional modifications of the product
▪ Using non original or non admitted parts or equipment
2.4 Standards and norms
LCOS Unmanaged switches are state of the technology and comply with the
applicable safety regulations and the corresponding harmonized European
standards (EN).
(As at: 21.08.2018)
EN 61131-2 Industrial-process control systems - Instruments with
analogue inputs and two- or multi-state outputs - Part 2:
Guidance for inspection and routine testing (IEC 65B/957/
CD:2014)
EN 61000-6-2 Electromagnetic compatibility (EMC) - Part 6-2: Generic
standards - Immunity standard for industrial environments
(IEC 77/488/CDV:2015); German version FprEN 61000-6-
2:2015
EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic
standards - Emission standard for industrial environments
(IEC 61000-6-4:2006 + A1:2010); German version
EN 61000-6-4:2007 + A1:2011
UL 61010-1 Safety requirements for electrical equipment for
measurement, control and laboratory use - Part 1: General
requirements (IEC 61010-1:2010 + Cor. :2011); German
version EN 61010-1:2010
UL 61010-2-201
(IEC 61010-2-201)
Safety Requirements for Electrical Equipment for
Measurement, Control, and Laboratory Use - Part 2-201:
Particular Requirements for Control Equipment (IEC 65/
582/CD:2014)
The current issue status of the standards as well as further information
on the product can be found in the respective data sheets.
The constantly updated data sheets can be found at www.luetze.com
Enter either the product name: LCOS Unmanaged Switch or this article
number: 77920* into the search field.
Here you will always find the latest documents (e.g. operating instructions) for
the products as well as further articles and technical information.

LCOS Unmanaged Switch ▪ General Information
8
TRANSPORTATION
2.5 Scope of validity of the manual
These operating instructions apply exclusively to devices with the following item
number(s):
1.) 779200.0401 / 779201.0401 - LCOS Unmanaged Switch 4 ports
2.) 779200.0801 / 779201.0801 - LCOS Unmanaged Switch 8 ports
The 9-digit article number of the device can be taken from the first number on the
Identification label.
2.5.1 Identification label
The identification plate contains the required markings for the respective product
and provides important technical data.
The identification plate, which has the following structure, is located on the
device:
:
Abb. 1: Identification plate (example)
The identification label contains the following information:
1. Part number
2. Assembly designation / module description
3. Module Description
4. Version number / Firmware Version (SW) (Empty in the example)
5. Hardware Revision (HW)
6. Serial number (X) / place of manufacture (YYY) / batch identification (Z)
7. Company address / place of production (YYY: "LUT" for Weinstadt and "EQQ"
for Czech Republic)
8. Block diagram
9. Company name / web address
10.Approvals / declarations of conformity (e.g. CE marking, UL, etc.)
11.2D barcode with product information
Note the identification label.
▪ The identification label should always be visual
▪ If there is a fault, the part number and serial number are needed.

LCOS Unmanaged Switch ▪ General Information
9
TRANSPORTATION
2.6 Approvals
2.6.1 Notes on CE labelling
Observe the original information signs, inscriptions, identification plates
and stickers. Keep them in a readable condition.
The devices comply with the provisions of the following European Directive: 89/
336/EEC Council Directive on the approximation of the laws of the Member
States relating to electromagnetic compatibility (amended by Directives 91/263/
EEC, 92/31/EEC and 93/68/EEC).
The EU Declaration of Conformity is kept available for the competent authorities
in accordance with the above-mentioned EU directives:
Friedrich Lütze GmbH
Bruckwiesenstraße 17-19
71384 Weinstadt
GERMANY / DEUTSCHLAND
Telefon: +49 7151 60530
Telefax: +49 7151 6053277
E-Mail: info(at)luetze.de
The product can be used in industry.
- Immunity to interference: EN 61131-2:2007 Zone B
- Emitted interference:
EN 61131:2007 und CFR-47 Part 15, Subpart B, class B
Strict compliance with the assembly guidelines specified in this
description and operating instructions is a prerequisite for compliance
with the EMC limit values.

LCOS Unmanaged Switch ▪ General Information
10
TRANSPORTATION
2.6.2 FCC Warning Statements
1. This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause un-
desired operation. Any Changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to ope-
rate the equipment.
2. Any Changes or modifications not expressly approved by the party respon-
sible for compliance could void the user's authority to operate the equip-
ment.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
▪ -Reorient or relocate the receiving antenna.
▪ -Increase the separation between the equipment and receiver.
▪ -Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
▪ -Consult the dealer or an experienced radio/TV technician for help.

LCOS Unmanaged Switch ▪ General Information
11
TRANSPORTATION
2.7 Applicable documents
2.7.1 Observe other applicable documents
When operating the LCOS Unmanaged Switch, please also observe all operating
instructions enclosed with other components of your system.
For reasons of clarity, we would like to point out that these operating instructions
cannot describe all conceivable problems in connection with the use of this
device.
Should you require further information or encounter special problems that are not
dealt with in sufficient detail in the operating instructions, you can request the
necessary information about service from Lütze. (See chapter „14 Service“ on
page 47)
Further documents are valid in conjunction with these operating
instructions. We accept no liability for damage caused by non-
observance of these instructions.
Always keep these operating instructions and the other applicable
documents (e.g. data sheets, package inserts, declarations of conformity,
etc.) at hand so that they are available when required.
This applies until the device is disposed of. Hand over all documents in case of
sale, distribution or rental of the device.

LCOS Unmanaged Switch ▪ Safety
12
TRANSPORTATION
3Safety
3.1 Contents of the operating instructions
These operating instructions must be read and observed before any work is
carried out on or with the units. This applies to all persons who come into contact
with the devices. Trained personnel and specialists, especially electricians (see
also chapter „3.5.1.3 Electrically qualified persons“ on page 14) who have
already worked with similar equipment should also have read and understood the
manual.
3.2 Applicable documents
3.3 Appropriate Use
The LCOS Unmanaged Switches are designed for industrial use in factory,
machine and building automation.
Due to the modular design, the devices in the LCOS system can be supplied
either via existing connectors or via the power bus (PB). Due to the possibility to
supply the devices with AC, they can also be used in building automation.
These instructions must be read and understood before installing,
operating or maintaining the device.
Risk of injury and damage to property due to non-observance of the
applicable documents*, in particular the safety instructions in the
respective package inserts.
This operating instruction alone is not sufficient if the modules are operated in
one system.
To avoid injury and damage, read the applicable and associated documents
before you plan the system.
*A list of other applicable documents can be found in
chapter „2.7 Mitgeltende Unterlagen“ on page 11
The products may only be used for the applications specified here in this
operating instruction, in the catalogue and in the associated technical
documentation.
Use of the device in a manner not specified by the manufacturer may impair the
protection and safety provided by the device.
The device is used exclusively for the purpose contractually agreed
between manufacturer and user.
Any other use or use beyond this is considered improper use. The
manufacturer is not liable for any damage resulting from this.

LCOS Unmanaged Switch ▪ Safety
13
TRANSPORTATION
Also note the following:
The intended use also includes the procedure according to the operating
instructions.
Any other or extended use is considered improper and therefore improper. In this
case, safety and its protection can be impaired. The company Friedrich Lütze
GmbH is not liable for any damages arising from this.
Intended use also includes:
▪ Observing all notes in the operating instructions
▪ Observing all safety instructions
3.4 Product life
The product life cycle of LCOS Unmanaged Switches is based on the
EN/IEC 61709 is calculated and defined.
Correct and safe operation of the product requires proper transport,
storage, installation and assembly as well as careful operation and
maintenance.
The permissible ambient conditions must be observed. These data are given in
the data sheets.
Operate the devices only in accordance with this intended case and only
in conjunction with the third-party devices and components
recommended or approved by us.
The devices may only be connected to the supply voltage printed on the
identification plate.
To reduce or avoid risks, please ask in case of doubt whether the third-
party devices and components used are approved or recommended by
us.
The current MTBF values can be taken from the corresponding data
sheet.

LCOS Unmanaged Switch ▪ Safety
14
TRANSPORTATION
3.5 Addressees
This operating instruction is directed towards planers, project managers and
programmers, as well as to staff authorized to commission, operate and maintain
the devices and systems. A distinction is made between various qualification
levels of the staff.
3.5.1 Operating Personnel
The operating instructions are directed at the operator and the personnel with the
following areas of competence:
3.5.1.1 Trained Employee
The employee was trained by the employer on the task and possible hazardous
situations. The employee does not have any technical knowledge.
3.5.1.2 Experts
The employee has a technical education, knowledge and/or experience in the
required field. The employee is capable to perform specific operations on and with
the product.
3.5.1.3 Electrically qualified persons
The employee has a technical education in the required field. The employee is
capable to perform special operations on and with the product.
The different sections of the document refer to the qualification level of the
operating personnel.
According to European Standard EN 50110-1:2008-09-01 Section 3.2.3
Working range Competency
Installation, transport and storage Experts
Commissioning, decommissioning Trained Employee
Operation Trained Employee
Servicing and maintenance Experts
Troubleshooting Experts
Risk of injury by usage through insufficient qualified operating
personnel! Misusage through performed insufficient or qualified personnel can
cause property damage and personal injuries.
▪ Tasks which apply special procedures should be done by trained and
qualified employees or experts, especially electricians.
(according to EN 60204-1)
The individual sections refer to the qualification level of the personnel.

LCOS Unmanaged Switch ▪ Safety
15
TRANSPORTATION
3.6 Responsibility of the operator
Since the device is used in a commercial area, the operator of the device is
subject to the legal obligations for occupational safety:
▪ The operator of the device is obliged to instruct the operating personnel and
to inform himself about the industrial safety regulations.
▪ The operator must ensure that safety, accident prevention and environmental
protection regulations are observed.
▪ The operator must make an appropriate risk assessment on the
▪ Workplace/location to detect and warn of special hazards.
▪ The manual must be kept in the immediate vicinity of the device.
▪ The information in the operating instructions must be followed.
▪ The device may only be operated in technically perfect condition.
3.7 Changes and modifications to the devices
Do not make any changes or modifications to the devices that have not been
expressly and in writing previously approved by Friedrich Lütze GmbH.
3.8 Safety device
3.9 Special safety notes
LCOS Unmanaged Switches are state of the technology and comply with the
applicable safety regulations and the corresponding harmonized European
standards (EN) - See also chapter „2.4 Standards and norms“ on page 7.
The following applies to the users:
▪ relevant and national accident prevention regulations
▪ EC directives or other country-specific regulations
Modifications and conversions lead to personal injury and property
damage!
Unauthorized modifications to the product may result in electric shock or injury
and destroy the product.
▪ Do not make any changes or modifications to the product.
▪ If a modification or change cannot be avoided, have the modification
approved in writing by Friedrich Lütze GmbH.
Sabotage of the devices can lead to serious errors in the overall system.
Install the LCOS Unmanaged Switch in such a way that it is not freely
accessible to unauthorized personnel and other persons.
Do not bypass or bypass the protective and safety devices.
Overvoltage can cause electric shocks and destroy the equipment.

LCOS Unmanaged Switch ▪ Safety
16
TRANSPORTATION
▪ generally accepted safety rules
▪ general ESD regulations.
The unit is to be connected only to internal Ethernet networks without
exiting a facility and being subjected to TNVs.
To avoid electric shock, this device may only be connected to Ethernet
networks within a building that are not connected to TNV circuits. Do not use a
telephone line voltage (TNV)! (This note is particularly relevant for North
America and Canada.)
The input/output connections comply with the Safety Extra Low Voltage (SELV)
guidelines for extra-low voltage devices. With TNV circuits, higher voltages
must be expected, e.g. due to lightning strikes. Therefore, they must not be
connected to SELV circuits.
Short-circuits and electric shocks due to incorrect application of the
voltage!
Current can injure persons and destroy the device. Before commissioning,
disconnect the entire system from the power supply and check the connections
after applying power.
Accidents during installation or maintenance due to electrical voltages!
When carrying out installation or maintenance work, disconnect the modules
from the power supply (pull out the mains plug). This prevents accidents
caused by electrical voltages.
Risk of injury from electric current.
Current can injure persons and destroy the device. For this reason, disconnect
the system from the power supply before installation.
Risk of injury and material damage through non-observance of the
operating instructions.
Always read the operating instructions before planning the system in order to
avoid or reduce risks and damage. (The instruction leaflet does not replace the
operating instructions of the product.
You can also find these operating instructions at www.luetze.com.
For electrical welding work on frames, all assemblies and their
connections must be disconnected.
If electronic assemblies are mounted on the frame, then all connections to and
from these assemblies must be disconnected beforehand.
Non-observance can destroy the devices by equalising currents.

LCOS Unmanaged Switch ▪ Safety
17
TRANSPORTATION
3.10 Further safety notes
Follow the ESD regulations.
Only use certified components. Only this way a reliable functioning is
ensured.
Follow the valid safety regulations and general regulations regarding the
technical standards.
The conductor size has to be selected dependig on the load current and
must be conform with international and national ruls and standards.
ATTENTION! The supply cable must be suitable for an operating
temperature range of -25 °C to +70 °C.
The connecting cables must be designed for the ambient temperature.
To ensure UL certification of the complete module, only use the plug-in
terminals recommended by us.
For UL applications: An UL-approved 3A fuse must be connected
upstream of the device.
For UL applications: Ambient temperature: +70 °C
The device has to be installed in a fire enclosure depending on the end
user application.
The device is intended to be used in indoor applications and be mounted
in cabinets.

LCOS Unmanaged Switch ▪ Product Overview
18
TRANSPORTATION
4Product Overview
4.1 Construction types
4.1.1 779200.0401 - Unmanaged Switch 4 ports
Abb. 2: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 4 ports
4.1.2 779200.0801 - Unmanaged Switch 8 ports
Abb. 3: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 8 ports
4.1.3 779201.0401 - Unmanaged Switch 4 ports
Abb. 4: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 4 ports
4.1.4 779201.0801 - Unmanaged Switch 8 ports
Abb. 5: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 8 ports

LCOS Unmanaged Switch ▪ Product Overview
19
TRANSPORTATION
4.2 Overview of product features
4.2.1 LCOS Unmanaged Ethernet Switches
The LCOS-SW-4P or LCOS-SW-8P Unmanaged Ethernet Switch is a switch for
use in industrial environments. It supports ETHERNET 10 MBit/s and Fast
ETHERNET 100 MBit/s.
The switch modules enable the construction of switched Ethernet networks
according to the IEEE 802.3 or 802.3u standard with twisted-pair cables.
The switch modules can be mounted directly on the top-hat rail via a function
carrier and are powered either via the LCOS power bus (PB) or the 3-pole
connection terminal. With their compact design, the modules can be mounted in
a terminal box.
The LCOS-SW-4P devices have four 10/100 Mbps twisted pair ports (10/
100BASE-TX, RJ45 connectors) and the LCOS-SW-8P devices have eight 10/
100 Mbps twisted pair ports (10/100BASE-TX, RJ45 connectors).
Twisted pair devices or other TP/TX segments can be connected to the ports. The
TP ports support auto negotiation, auto polarity and auto MDI/MDI-X. In addition,
the devices evaluate the Ethernet frame-based priority data (Qos) in order to
forward time-critical signals more quickly.
The power consumption is significantly reduced by an automatic switch-off of the
unused ports, but even at full load the power consumption of the 8 port version
remains below 2W. The extended operating temperature range allows operation
from - 25 °C to + 70°C ambient temperature.
4.2.2 Product Features of LCOS Unmanaged Ethernet Switches
▪ AC/DC 24V supply voltage
▪ Variable supply voltage supply
- Power bus (PB) or
- 3-pole plug-in terminal Push-In
▪ Can be used as a stand-alone module or in the "Lütze Communication
System".
▪ Compact design and universal application
▪ QoS - Quality of Services
▪ Extended temperature range
▪ CE - Declaration of Conformity
▪ UL - Approval
▪ FCC - Approval
This manual suits for next models
6
Table of contents
Popular Switch manuals by other brands

QSC
QSC Q-SYS NS Series Technical notes

3Com
3Com 4200G 12-Port Configuration guide

Moxa Technologies
Moxa Technologies EtherDevice EDS-P206A-4PoE Series Quick installation guide

Honeywell
Honeywell HDLS Series Installation instructions manual

Nlynx
Nlynx Wireless Gateway user guide

Extron electronics
Extron electronics mediaport 200 Setup guide