Lantech IDS-2102A User manual

IDS-2102A User’s Manual
1 RS-232/422/485 port to 2 10/100TX Ethernet Device
Server
May 2018
Version: 1.10

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
1
Table of Content
Getting Started...............................................................................................3
1.1 About IDS-2102A Series.......................................................................................3
1.2Hardware Specifications.......................................................................................3
Hardware Overview........................................................................................5
2.1 Front Panel...........................................................................................................5
2.1.1 Ports and Connectors.......................................................................................5
2.1.2 LED..................................................................................................................6
2.2 Top Panel.............................................................................................................6
2.3 Rear Panel ...........................................................................................................6
Hardware Installation.....................................................................................8
3.1 DIN-rail Installation ...............................................................................................8
3.2 Wall Mounting.......................................................................................................9
3.3 Wiring.................................................................................................................10
3.3.1 Grounding ..........................................................................................................10
3.3.2 Redundant Power Inputs .................................................................................... 11
3.4 Connection......................................................................................................... 11
3.4.1 Cables................................................................................................................ 11
10/100BASE-T(X) PinAssignments............................................................................. 11
DB9 console port wiring ..............................................................................................12
Management.................................................................................................13
4.1 DS-Tool ..............................................................................................................13
4.1.1 Install DS-Tool....................................................................................................13
4.1.2 Using DS-Tool.....................................................................................................14
4.1.3 Configure Device Servers...................................................................................15
4.1.4 Configure Serial Port ..........................................................................................22
Serial Settings..............................................................................................22
Service Mode................................................................................................25
Notification...................................................................................................30
4.2 Web Management ..............................................................................................31
4.2.1 Settings..............................................................................................................32

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
2
System..........................................................................................................32
Port Serial Setting........................................................................................36
Management.................................................................................................43
Save/Reboot.................................................................................................47
4.3 Configuration by SSH Console............................................................................48
4.3.1 Connect to DS....................................................................................................48

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
3
Getting Started
1.1 About IDS-2102A Series
The IDS-2102A is an industrial device server with one RS-232/422/485 port and two LAN
ports designed for converting signals between serial and Ethernet networks. It provides
standard features of device servers such as TCP/IP interfaces and versatile operation
modes including Virtual Com, Serial Tunnel, TCP Server, TCP Client, UDP. The device
also supports Windows utility DS-Tool which allows you to configure multiple devices and
set up the mappings of Virtual Com. The features of NAT Router Pass Through, make it
more convenient for administrators to configure Lantech’s device servers through a NAT
router from different IP domains or Internet via modem remotely. The device can transfer
data to five host PCs simultaneously for redundancy in case of Ethernet connection
breakdown or host PC failure. Further, the device supports HTTPS, SSH, and SSL
encryption to assure the security of critical data transmission.
Software Features
Supports five host devices including Virtual COM, TCP Server, TCP Client modes
and four IP ranges
Supports operating modes such as Virtual Com, Serial Tunnel, TCP Server, TCP
Client, UDP
NAT-pass through support for users to manage IDS-2102A through NAT router
Ensure high levels of security with SSL data encryption, HTTPS/SSH, IP access
control and IP white list
Event warning by Syslog, Email, SNMP trap, and beeper
Configurable by Web Interface and Windows utility
Configurable by Windows utility (DS-Tool)
Various Windows OS supported: Windows NT/2000/ XP/ 2003/VISTA(32/64bit)/
Windows 7(32/64bit)
1.2 Hardware Specifications
1 x RS-232/422/485 serial ports
2 x 10/100Base-T(X) Ethernet ports
DIN-rail and wall-mount enabled
Redundant DC power inputs
Operating Temperature: -10 to 60oC
Storage Temperature: -40 to 85oC
Operating Humidity: 5% to 95%, non-condensing

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
4
Casing: IP-30
Dimensions: 26 (W) x 75 (D) x 110 (H) mm

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
5
Hardware Overview
2.1 Front Panel
2.1.1 Ports and Connectors
The device provides the following ports on the top panel. The Ethernet port on the device
use RJ-45 connectors
Port
Description
Copper port
2 x 10/100Base-T(X) port (one is PoE-enabled)
Serial port
1 x DB9 serial ports
IDS-2102A
1. Power status indicators
2. LAN port connection indicators
3. Serial signal reception status
indicator
4. DB9 serial port
5. RS 422/ 485 Termination
6. Ethernet ports

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
6
2.1.2 LED
LED
Color
Status
Description
Power
1/2
Green
On
Power is on and function normally
ETH
1/2
Green
On
Ethernet port link up
TX /
RX
Red
On
Receiving data
Green
On
Transmitting data
2.2 Top Panel
Below are the top panel components of the device:
1. Terminal blocks: PWR1, PWR2,
2. Reset default button
3. Ground wire. For more information on how to ground the switch, please refer to 3.3.1
Grounding.
2.3 Rear Panel
1. Wall-Mount screw holes
2. Din-rail
1. DIN-rail screw holes

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
7

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
8
Hardware Installation
3.1 DIN-rail Installation
The device comes with a DIN-rail kit to allow you to fasten the device to a DIN-rail in any
environments.
DIN-rail Kit Measurement (unit = mm)
Installing the device on the DIN-rail is easy. First, screw the Din-rail kit onto the back of the
device, right in the middle of the back panel. Then slide the device onto a DIN-rail from the
Din-rail kit and make sure the device clicks into the rail firmly.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
9
3.2 Wall Mounting
Besides Din-rail, the device can be fixed to the wall via wall mount kits, which can be
found in the package.
Wall-Mount Kit Measurement (unit = mm)
Follow the steps below to install the device to a rack.
Step 1: Install the L-shape mounting kits provided in the package to the left and right of the
device.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
10
Step 2: With front brackets orientated in front of the rack, mount the device in the rack with
four rack-mounting screws.
3.3 Wiring
3.3.1 Grounding
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground pin on the power module to the grounding surface prior to
connecting devices.
ATTENTION
1. Be sure to disconnect the power cord before installing and/or wiring
your devices.
2. Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating themaximum
current allowable for each wire size.
3. If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.
4. Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.
5. Do not run signal or communications wiring and power wiring
through the same wire conduit. To avoid interference, wires with
different signal characteristics should be routed separately.
6. You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb is
that wiring sharing similar electrical characteristics can be bundled
together
7. You should separate input wiring from output wiring
8. It is advised to label the wiring to all devices in the system
WARNING
Do not disconnect modules or wires unless power has been switched off
or the area is known to be non-hazardous. The devices may only be
connected to the supply voltage shown on the type plate.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
11
3.3.2 Redundant Power Inputs
The device has two sets of DC power inputs on a 4-pin terminal block located on top of the
device. Follow the steps below to wire the power input on the terminal block.
Step 1: insert the negative/positive wires into the V-/V+ terminals, respectively.
Step 2: to keep the wires from pulling loose, use a small flat-blade screwdriver to tighten
the wire-clamp screws on the front of the terminal block connector.
3.4 Connection
3.4.1 Cables
10/100BASE-T(X) Pin Assignments
The device has two standard Ethernet ports. According to the link type, the device uses
CAT 3, 4, 5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
Cable
Type
Max. Length
Connect
or
10BASE-T
Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
UTP 100 m (328 ft)
RJ-45
With 10/100Base-T(X) cables, pins 1 and 2 are used for transmitting data, and pins 3 and
6 are used for receiving data.
10/100 Base-T(X) RJ-45 PinAssignments :
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
The device also supports auto MDI/MDI-X operation. You can use a cable to connect the

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
12
device to a PC. The table below shows the 10/100Base-T(X) MDI and MDI-X port pin
outs.
10/100 Base-T(X) MDI/MDI-X PinAssignments:
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
DB9 console port wiring
The serial ports can be connected using a DB9 cable. The DB9 connector supports RS232 /
RS422 / RS485 operation modes. Please refer to the following table for the pin assignments of
the DB9 connector.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
13
Management
4.1 DS-Tool
The Windows utility DS-Tool is a powerful Windows utility for DS series. It supports device
discovery, device configuration, group setup, group firmware update, and monitoring functions.
The tool enables you to easily install and configure devices on the network.
4.1.1 Install DS-Tool
Follow the steps below to install the tool.
Step 1: Run the Setup program by clicking Start after selecting the folder for DS-Tool.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
14
Step 2: When installation completes successfully, click OK.
Step 3: You can launch the tool right immediately by checking Launch DS-Tool Now or launch
it later by checking Launch DS-Tool Later.
4.1.2 Using DS-Tool
Explore device servers
DS-Tool will broadcast to the network and search all available DS devices in the network
automatically. The default IP address of the device is “192.168.10.2”. Select the device you
wish to use and press Add button.
You can set a static IP address or use the DHCP client mode to acquire an IP address
automatically. Click OK and the device will be added.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
15
4.1.3 Configure Device Servers
General
This page enables you to perform general configuration for the device, includes the device
name, SNTP server, and auto IP report.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
16
Label
Description
Device Name/Location
You can input the device name or related information in this
field. By clicking Locate On, you can locate the serial server’s
position.
Using SNTP Time Server
If you want to set the time via a SNTP time server, check the
box and input related information such as the SNTP server
domain name or IP address and the port number, and select a
time zone.
Auto IP Report
Check the Auto IP Report box if you want to receive IPreport
regularly. By Clicking the Get Current Host, you will get your
local IP address. Input a value in the Report Interval time
based on how often you want the device server to report its
status.
Security
This page allows you to set up access IP tables for your device to allow authorized and deny
unauthorized access, thereby ensuring data security and facilitating device management.

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
17
Label
Description
Access IP Table
You can input the host IP addresses and network masks to prevent
unauthorized access.
Password
You can set the password to prevent unauthorized access from your
server. Factory default is no password.
Ethernet
You must assign a valid IP address for DS before attached in your network environment. Your
network administrator should provide you the IP address and related settings. The IP address
must be unique within the network (otherwise, DS will not have a valid connection to the
network). You can choose from three possible “IP configuration” modes: Static,
DHCP/BOOTP. The Factory Default IP address is “192.168.10.2”

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
18
Label
Description
Using Static IP
Manually assign an IP address to the device.
Using DHCP/BOOTP
Check this box to have the IP address automatically assigned by
a DHCP server in your network.
Netmask
All devices on the network must have the same subnet mask to
communicate on the network.
Gateway
Enter the IP address of the router in you network.
DNS1/2
Enter the IP addresses of the primary and secondary DNS
servers, The DNS server translates domain names into IP
address.
Notification
Specify the events that should be notified to the administrator. The events can be alarmed by
E-mail, SNMP trap, or Syslog.
Label
Description
SNMP Trap
Check the box to allow the system to send SNMP traps when an

IDS-2102A User’s Manual
Lantech Communications Global, Inc.
19
event occurs. SNMP traps are data packages sent from the
SNMP client to the server without being explicitly requested. You
need to set up trap servers that will receive these messages if
the box is checked.
Email Notification
Check the box to allow the system to send e-mails when an
event occurs. You need to specify the SMTP Server and
the email address to use for sending emails if the box is
checked.
Syslog Notification
Check the box to allow the system to send a detailed log to an
external Syslog server when an event occurs. The syslog will
capture all log activity and includes every connection source and
destination IP address, IP service, and number of bytes
transferred to facilitate troubleshooting. You need to enter Server
IP address and Server Port of the syslog server.
Notified items
Select the corresponding check box to send an event alert to a
remote syslog sever
・Hardware Reset (Cold Start): Rebooting the device from power
plug will trigger the event
Table of contents
Popular Server manuals by other brands

Axis
Axis 7000 user manual

TimeIPS
TimeIPS IPS300T installation guide

Fujitsu
Fujitsu PRIMERGY TX1330 M3 operating manual

Moxa Technologies
Moxa Technologies NPort 6450 Series Quick installation guide

Fujitsu
Fujitsu PRIMERGY RX300 S6 operating manual

Supermicro
Supermicro SuperServer SYS-110P-FRN2T user manual