Laser Optronix GyroView 3 User manual

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 1
Gyroview 3 the 16x40 Gyro
BINOCULAR WITH ACTIVE IMAGE STABILIZATION

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 2
IMPORTANT INFORMATION
Read prior to activation
You have just purchased a complicated electro mechanical device. To operate it properly, please
read this manual carefully. Here are
some common precautions that must be noted.
•NEVER hit the unit while operating or being transported
•NEVER transport the unit without the case
•NEVER disassemble the unit. This device contains high speed rotating parts, which may be
hazardous to you!
•NEVER engage the stabilizing mode while the power supply control indicator is not glowing or
less than 1 minute after activating the unit
•NEVER turn off the unit while stabilizing mode is engaged
•NEVER reverse the polarity of a battery
In operation smart users do following
•ALWAYS remove batteries when not in use for a long period
•ALWAYS keep the objective lenses covered when not in use
•ALWAYS store in a warm dry place when not in use
Features of the Gyroview 16x40 Gyro binoculars
•Stabilized image by high sped gyro system ritating at 12000-14000 RPM
•Rigid construction
•Dual eye pieces
•Diopter adjustment for booth eye pieces
•Value priced 70% below competition
•Textile bag and maintenance equipment in the bag
•Water Resistant IP 44 level ( We have a IP 67 water proof model on request )
•Night Vision eyepieces and adapters (optional)
•Operation on integrated batteries or external power source

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 3
CONTENTS
1. Brief description
2. Appearance of the device
3. Technical characteristic
4. Supplied accessories
5. Operation instructions
5.1. Preparing the device for operation without image stabilization
5.2. Preparing the device for operation with image stabilization
5.3. Preparing the device for operation from on- board source
6. Storage and maintenance instructions
7. Trouble shooting
8. Warranty
9. Customer Support
BEFORE USE CAREFULLY READ ALL THE INSTRUCTIONS!
FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANTY!
1. BRIEF DESCRIPTION
Gyro view 16x40GR Gyro Stabilizing Binoculars is a modern,universal optical device
designed for observation and tracking of distant objects and serve both amateur and professional
needs:
•Observation aboard aircraft, land vehicles, boats or othermoving platforms
•Law enforcement and security
•Search and rescue
•Military
•Space
•Used by coast guard and naval aviation for SAR applications in several countries
•Active stabilizzation and can not be compared to other solutions based on flexible suspended
prism optics whichg do not work on boats and in aircrafts in a useable way
The device incorporates the image stabilization technology, which enables the user to observe distant
objects from moving and nonmoving platforms without degrading of the image resolution because of jolt or
normal hand tremors
Combining fully coated, computer designed optics with high- speed internal gyrostabilizing system,
GW 16• 40GR is the ultimate instrument for long- range observation, tracking and surveillance. High
magnification, easy to carry and handle allow shake free observation under any demanding
conditions.

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 4
Fig. 1
For ease of operation, the device is fitted with neck strap (7) and
hand strap (1). Eyepieces (8), interpupillary adjustment lever (9)
and stabilizing mode engaging lever (5) are positioned on the
front panel (6) of the device. Power supply unit (2) is a
detachable part of the device.
Power supply voltage switch (4) and power supply control
indicator (3) are at the front of the device.
1 –cartridge with AA type batteries; 2 –connector;
3 –pin; 4 –cramp; 5 –delimiter; 6 –lock
Fig. 2 – Power Supply Unit
The device is powered by either a cartridge with batteries (1) or by an on- board power source 12± 1.2 V via
connector (2).The power supply unit is attached to the device using delimiter(5) and lock (6).
Pin (3) opens the delimiter of the power supply unit.
Cartridge (1) with batteries is fixed in the power supply unit with cramp (4).

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 5
3. TECHNICAL CHARACTERISTICS
Magnification 16 x
Angular field of view 3.4°
Exit pupil diameter, mm 2.5
Minimum focus, m 30
Interpupillary adjustment, mm: 58 – 72
Dioptric adjustment, not less, dptr ±5
Transmission factor, not less 0.55
Parallelism of eyepiece axes of sight:
- Divergence on vertical plane, not exceeding: 20’
- Convergence on horizontal plane, not exceeding: 20’
- Divergence on horizontal plane, not exceeding: 60’
Power source (batteries): 6 (AA)
From an on- board source, 12 VDC max 1 A
Angular velocity of panning in any direction, degree/ sec: 0 - 6
Stabilization freedom, degrees ±5
Overall dimensions, mm: 215• 190• 96
Weight (w/ o batteries), kg, 1.98
Relative humidity (at +25° C) %: Up to 98%
Temperature range, °C -30 ÷+45
Temperature range during transportation, o C -50 ÷+50
4. SUPPLIED ACCESSORIES
SIB 16x40 Gyro is supplied in the following assembly:
- Device 1 pcs
- Objective lens caps 2 pcs
- Carrying Case 1 pcs
- Neck Strap 1 pcs
- Hand Strap 1 pcs
- DC regulator 1 pcs
- User’s manual 1 pcs
- Warranty card 1 pcs as a page in this manual
Optional accessories :
- Amber Filters (optional) 2 pcs
-Night Vision eyepieces (optional) 1-2 pcs
5. OPERATION INSTRUCTIONS
5.1. Preparing the Device for Operation without Image Stabilization
1. Remove the device from the case and adjust neck strap (7) and hand strap (1) (fig. 1).
2. Remove the protective caps from the objective lenses and, if necessary, mount the optional light
filters.
3. Adjust the interpupillary distance- using lever (9).
4. Adjust the dioptric correction by rotating rings on the eyepieces (8).
5. Now the device can operate as a conventional 16 x magnification binocular.

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 6
5.2. Preparing the Device for Operation with Image
Stabilization
1. Put the lens caps on the objective lenses. Take the power supply unit in your left hand.
2. Pull out pin (3) on the power supply unit (fig. 2) and disconnect the power supply unit from
the device with an easy movement towards you.
3. Insert six AA batteries into the cartridge (1) (fig. 2) observing correct polarity.
4. Mount the cartridge with batteries into the power supply unit (2) (fig. 1) and secure it by cramp (4) (fig. 2).
5. ATTENTION! To avoid damage of the cramp, while mounting the cartridge into the power supply
unit, particular attention must be drawn to its position respecting to the body of the power supply
unit. While the cartridge is being mounted into the power supply unit, the cramp should be
placed above the cartridge.
6. In order to connect the power supply unit to the device, pull out pin (3) with an easy movement
in the direction away from you and then release the locator to bring the power supply unit against
the delimiter. Turn on the device by setting supply voltage switch (4) (fig. 1) to ON position and
check the power supply unit for proper operation (indicator (3) must glow brightly).
7. In no less than a minute, press lever 5 (fig. 1) in the arrow indicated direction in order to
engage the stabilizing mode and hold it in this position while observing.
ATTENTION! It is not allowed to engage the stabilizing mode
of the device when the power supply control indicator is not glowing, or in less than a minute
after device has been turned ON.
When finishing the observation
release lever 5 (fig. 1). The lever should return to the initialposition. Now the stabilizing mode
has been switched off.Switch OFF the power supply unit.
5.3. Preparing the Device for Operation from On- board Source
1. Replace the cartridge with batteries 1 (fig. 2) with a voltage transformer available in the
complete set of the device.
2. Connect the cable, supplied in the complete set, to the power supply unit connector 2 (fig. 2).
3. Connect the device to the on- board power source.
4. Then prepare the device for operation as outlined in the paragraph 5.2.
6. STORAGE AND MAINTENANCE INSTRUCTIONS.
Warning ! After transportation or keeping the device at temperature lower than –25 °C (– 13 °F), the device
must be warmed up to ambient temperature for at least 6 hours before operating .
Precautions: SIB 16x40 GR is a sophisticated precision optical instrument equipped with
electronics. Therefore, it should be handled with due care.
•Keep your device away from direct sunlight, impacts, dust, moisture, and sudden changes of
temperatures.
•Do not keep the device at temperatures higher than 50 o C (122 o F).
•Do not touch the optical surfaces with fingers. Doing so may damage the anti- reflection coating.
•Avoid shocks and sharp jolts.
•Cleaning of optical surfaces is only allowed with professional camera lens cleaning supplies.
•To clean the exterior of the device, use a soft clean cloth.
•Do not take the cover off the lens if not necessary.
•Keep away from heating appliances and central heating.
•Make sure to switch off the unit during periods of non- operation.

GyroView 3 Manual
Laseroptronix Telephone office 0046-70 714 04 70
Enhagsslingan 23
187 40 Täby Sweden
Page 7
•Remove the batteries when storing the device for long period of time.
•Do not apply superfluous efforts at work with lens assembly, agile elements and thread
connections.
•The manufacturer can only make repair works.
•Due to considerable optical magnification of the optional night eyepiece some small structures
inside the tube coating in the form of dark and/ or white points may be seen in the field of view,
which does not affect the serviceability of the device.
7. TROUBLE SHOOTING
The stabilizing mode does not work.
Check that the batteries are installed properly. Check
the charge of the batteries. Replace if they are weak. Do not use old batteries with new ones.
The image does not appear in focus.
Bring the inspected object to the center of the image.
Turning the eyepieces (8), adjust to achieve the clearest image on the screen. If the view still does
not seem in focus, clean the lenses. They could be foggy or dusty.
Image is ‘waving’ when stabilizing mode has been engaged.
This is a typical ‘warming-
up’ effect that will last for no more than one minute after engaging the stabilizing mode.
Condensation accumulates on the parts
In order to avoid misting of the eyepiece lens in cold
time use special protective covers.
Image has disappeared during nighttime observation (using optional
night eyepieces). When bright light gets into the objective lens of the night vision device it may
result in disappearing of the image as the automatic shut- off feature comes into action to protect
the device. Whenever this happens, turn the switch to the OFF position. In a minute or two the
device will be ready for further operation.
8. WARRANTY Gyro view binoculars.
Laseroptronix warrants this product against defects in material and workmanship for one year from the
date of the original date of consumer's purchase, but no more than 12 months from the date of
manufacturing. Should your GW3 product prove defective during this period, please bring the
product securely packaged in its original container or an equivalent, along with proof of the date of
original purchase, toyour Dealer. They will repair (or at its option replace), the product or part
thereof, which, on inspection by
Laseroptronix, is found to be defective in materials or workmanship.
What This Warranty Does Not Cover:
Laseroptronix is not responsible for warranty service should the product fail to be properly
maintained or fail to function properly as a result of misuse, abuse, improper installation,
neglect, damage caused by disasters such as fire, flood, lightning, improper electrical current, or
service other than by an Authorized Service.
Table of contents