manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leader Light
  6. •
  7. Dj Equipment
  8. •
  9. Leader Light LL STAGE WASH 600 User manual

Leader Light LL STAGE WASH 600 User manual

USER MANUAL
LL STAGE WASH 600/1200/1800
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
All dimensions are in millimeters
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only by a qualied
professional in accordance with relevant local codes.
01 SAFETY INFORMATION
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries and recommended AC power supply must be installed by a qualied
professional in accordance with relevant local codes. Only acceptable source of AC power
and frequency that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or xtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect it from AC power.
Appliance always connect to earth (eltech.).
-
-
-
-
-
-
01.3 Fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the tting (180°) must be maintained space for
cooling.
Minimum distance from the surrounding objects must be 100mm (4 in.).
LEDs never direct cover with lters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets. The housing never install directly to the
surface.
-
-
-
-
-
-
02 PRODUCT SPECIFICATION
02.1 Technical Specication
LED INDICATION STATUS
POWER (Green) blinking – 2Hz OK - inside xture is everything correct
DATA (Yellow) light off NO DMX512 signal
DATA (Yellow) blinking – 4Hz OK- income correct DMX512 signal
DATA (Yellow) fast blinking NON correct digital signal
POWER (Green) alternate blinking Autotest function
DATA (Yellow)
Control LEDs Indication POWER DATA
03 INSTALLATION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable for
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...).
Hairbreadth from combustible materials is 0,5m.
Before physical installation insert the optic modul on front of luminary. The optic installa-
tion is easy and fast by 2 screws. (gures Nr. 3.1 to 3.2)
-
-
-
03.3 Connecting to AC power
To tackle all Safety Information- 01!
For protection from electric shock, the device must be grounded (earthed)!
It is not necessary to open the xture before power supply. Power supply is solved
simple with Neutrik PowerCon connectors.
The xture is equipped with auto-switching power supply that automatically adjusts to
any 50-60Hz AC power source from 100-260V.
Cord plug connections:
-
-
-
-
-
©MMX - Leader Light – All right reserved
02.2 Back panel
If you have any question please, contact [email protected]
COMPLIMENTS ON YOUR PURCHASE!
Symbol Pin Wire Colour Screw (US)
Llive brown yellow or brass
Nneutral blue silver
ground (earth) yellow/green green
03.4 Control data connecting
Control data cable length is specied by Norm IEC929 Annex E4.
It is not necessary to open the xture before connecting of DMX512 control signal.
Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
Content:
01 SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRODUCT SPECIFICATION
02.1 Technical Specication
02.2 Back panel
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC power
03.4 Control data connecting
03.5 DMX channels
04 PERMANENT USE AND DAISY CONNECTION LIMITATIONS
05 MAINTENANCE
Without optic: LL76 3xx
LL76 4xx
* P4: R-Red, G-Green, B-Blue, A-Amber, W-White (6300°K)
- UV: UV-Ultra Violet
Dip options
Rotating DIP address 000÷511
“100“ “10“ “1“
DMX Out
XLR-5pin
DMX In
XLR-5pin
Power In
PowerCon
Power Out
PowerCon
Control LEDs
LL STA G E WASH
Made in EU
Leader Light s.r.o.
Slovakia 2009
www.leaderlight.eu
[email protected]
MODE ADDRESS
POWER DATA
WARNING - Disconnect
mains before remove cover!
! !
WARNING!!!
Non-minimum distance and/or non-use
the original brackets is at your own risk!
ENVIRONMENT
Do not throw away the appliance with the normal household waste at the end
of its life, but hand it in at an ofcial collection point for recycling. By doing
this, you help to preserve the environment.
!!
WARNING!!! AWUV versions:
Overall allowable time of exposure of unprotected eyes in relation to the distance from the
light source results:
distance (m) 0,6m 1,0m 2,0m 3,0m
max. exposure time (h:m:s) 0:17:52 0:35:55 1:35:24 2:43:08
Following items are included:
1. Version without Vario optic
- LL STAGE WASH with adjustable bracket 1 pc.
- PowerCon type “A“ + “B“ 1 pc.
- User manual 1 pc.
2. Version with Vario optic
- LL STAGE WASH with adjustable bracket 1 pc.
- LL VARIO OPTIC WASH 600 25° 1 pc.
- PowerCon type “A“ + “B“ 1 pc.
- User manual 1 pc.
Additional items needed:
- Data cables with XLR 5pin Female/Male 1 pc.
- Controller compatible with DMX 1 pc.
- Mounting accessories as necessary
Surface mounting:
- Screws and washers M12 or M10 min. 4pcs.
Lamp type 600/1200/1800mm: 66/132/198 x LED *
VarioOptic 15°, 30°, 40°, 60°, EL (20°x40°)
Control data con-
nection DMX 512 In/Out with XLR 5pin
Power connection AC90-264V, 47-63Hz In/Out PowerCon
Max. input power 600/1200/1800mm: 102/203/306 W
Net weight 600/1200/1800mm: 5,5/11,0/17,0 kg (12,1/24,3/37,5 lb)
Lifetime 75.000 hours (70% lumen maintenance at Ta =+25ºC (77°F))
Ambient temp. (Ta) Maximum 40°C (104°F)
Cooling Conventional
Installation Fast mounting using Camlocs
Materials and nish Powder painted anodized aluminium in RAL 9005 (other colours on
request)
03.5 DMX channels - subject to change
The latest version of DMX channels appendix are on the websites - www. leaderlight.eu
If you have any question please, contact [email protected]
180°
AIMING POSSIBILITY
The xture could be aim to wish position with
adjustable bracket.
Ch. RGBAW AW AWUV
Mode1: Dip2=Off
1R 1, R 2, R 3 A 1, A 2, A 3 A 1, A 2, A 3
2G 1, G 2, G 3 W 1, W 2, W 3 W 1, W 2, W 3
3B 1, B 2, B 3 Master (Dip1=On, Dip4=Off) UV 1, UV 2, UV 3
4A 1, A 2, A 3 Strobo (Dip1=On, Dip4=Off) Master (Dip1=On, Dip4=Off)
5W 1, W 2, W 3 Strobo (Dip1=On, Dip4=Off)
6Master (Dip1=On, Dip4=Off)
7Strobo (Dip1=On, Dip4=Off)
Mode4: Dip2=On
1R 1 A 1 A 1
2G 1 W 1 W 1
3B 1 A 2 UV 1
4A 1 W 2 A 2
5W 1 A 3 W 2
6R 2 W 3 UV 2
7G 2 Master (Dip1=On,Dip4=Off) A 3
8B 2 Strobo (Dip1=On, Dip4=Off) W 3
9A 2 UV 3
10 W 2 Master (Dip1=On,Dip4=Off)
11 R 3 Strobo (Dip1=On, Dip4=Off)
12 G 3
13 B 3
14 A 3
15 W 3
16 Master (Dip1=On,Dip4=Off)
17 Strobo (Dip1=On, Dip4=Off)
Extention and control functions:
Dip4=Off, Dip1=Off =>DipBCD: use rotating switch for DMX start address
(RS1-100, RS2-010, RS3-001) from 001 to 511
Dip4=Off, Dip1=On: address+2channels (Master+Strobo)
Dip4=On, Dip1=Off: switch on AutoRun-table functions:
“100“=Prg.0-9, “10“=StepTime, “1“=FadeTime
Dip4=On, Dip1=On: switch all channels on 50% - test function
Dip2=Off: Mode 1 (5+2ch) Dip2=Off: Mode 1 (2+2ch) Dip2=Off: Mode 1 (3+2ch)
Dip2=On: Mode 4 (15+2ch) Dip2=On: Mode 4 (6+2ch) Dip2=On: Mode 4 (9+2ch)
Dip3=Off: standard curve
Dip3=On: ultraSoft curve
* Standard delivery with LL BRACKET STAGE ADJUSTABLE
** Vario Optic should be ordered separately
05 MAINTENANCE
To tackle all Safety Information- 01!
Damage caused by inadequate cleaning or maintenance is not covered by
warranty.
Regular cleaning is demand (dust, dirt, ...).
Maintenance policy:
Unplug mains before maintenance and at least 10 minutes cool off
Appliance do not illegal open or demount
Clean-up dust only from outer surface (for ex. scuttle, diffuser and lenses).
Use vacuum or dumpy duster (warm water)
Before reinstalling to check failure-free state – no wet parts!
-
-
-
-
-
-
-
-
Mechanical mounting of LL STAGE WASH on stage
Mounting on stage is easy using various accessories as seen below (Figures Nr. 1.1 to 1.4). The brackets are connect by Camlocs.
It is not necessary to open the xture for echange of Vario Optic (Figures Nr. 3.1 to 3.2).
3.2 Carefully remove the optic modul and insert the new one and x with screws.
1.1
Serial connection by LL36 600 for creation of continuous line
Camloc 1/4 turn fasteners
Safe mechanical quick release
fastener systems
Locking/unlocking by quarter turn
Hand operated
Service-friendly, time-saving
and cost cutting
Vibration-resistant
-
-
-
-
-1.2 Serial connection by LL36 610 for creation of line with extension
1.4 Parallel connection by triple bracket LL36 6301.3 Parallel connection by dual bracket LL36 620
Mechanical mounting of tubus and frame to the LL STAGE WASH
2.1 Fit the tube LL37 300 / LL37 303 part on top of tting. The tube screws screw into the tting holes.
The tube is ready to use.
Tube and frame installation without tools (Figures Nr. 2.1 to 2.2).
2.2 The frame must be installed together with tube
LL37 303
. The frame mount with screws on the
top of tube.
3.1 The optic installation is easy and fast by 2 screws.
LL36 600 LL36 610
LL36 620 LL36 630
Vario Optic installation
04 PERNAMENT USE LIMITATIONS FOR HEATING DISSIPATION
Pernament use limitations for heating dissipation of LL STAGE WASH RGBAW
body temperature must be less then 55°C
40°C ambient temperature -20% of total power
30°C ambient temperature -10% of total power
20°C ambient temperature -0% of total power
Black version - 30%
Silver or White version - 50%
Example: Then nal pernament value for BLACK colour and 40°C ambient
temperature = -30% -20% = 56% = max 143 ≥ (R + G + B + W +A) / 5
It‘s mean average of power go inside the xture at DMX signal
Example:
black LL STAGE WASH: 180 ≥ (R + G + B + W + A) / 5
Silver or White LL STAGE WASH: 128 ≥ (R + G + B + W +A) / 5
Value for R or G or B or W or A is 100% = 256 = 8bit levels *** RED 50% = 128
value, RED 75% = 192 value
Final information we don’t drop down each colour power with temperature
control to get maximum for each colour under total recomMendations , therefore
you need setup limitations from control desk !!!
DAISY CONNECTION LIMITATION:
6pcs 600mm LL STAGE WASH 600 or 3pcs 1200mm LL STAGE WASH 1200 is
possible to connect by daisy chain connection
-

This manual suits for next models

2

Other Leader Light Dj Equipment manuals

Leader Light LL STAGE CYC 6C User manual

Leader Light

Leader Light LL STAGE CYC 6C User manual

Leader Light LL36 085 User manual

Leader Light

Leader Light LL36 085 User manual

Popular Dj Equipment manuals by other brands

RedJET RJ230 user manual

RedJET

RedJET RJ230 user manual

ITC Elio VersiControl Install instructions

ITC

ITC Elio VersiControl Install instructions

Chauvet Professional OVATION B-1965FC user manual

Chauvet Professional

Chauvet Professional OVATION B-1965FC user manual

Varytec Typhoon True Kid 720Z RGBW IP65 user manual

Varytec

Varytec Typhoon True Kid 720Z RGBW IP65 user manual

Chauvet DJ Techno Strobe 2000S Quick reference guide

Chauvet DJ

Chauvet DJ Techno Strobe 2000S Quick reference guide

Intella storm 300 RGBW user manual

Intella

Intella storm 300 RGBW user manual

Robin SPIIDER user manual

Robin

Robin SPIIDER user manual

Party Light & Sound PARTY-DERBY6 user manual

Party Light & Sound

Party Light & Sound PARTY-DERBY6 user manual

Griven Professional ARCO 2000 PR1227 Fresnel instruction manual

Griven Professional

Griven Professional ARCO 2000 PR1227 Fresnel instruction manual

ADJ Eliminator Lighting FROST FX BAR W User instructions

ADJ

ADJ Eliminator Lighting FROST FX BAR W User instructions

Equinox Systems Hot Rod EQLED089 user manual

Equinox Systems

Equinox Systems Hot Rod EQLED089 user manual

Martin Rush Multibeam 2 user manual

Martin

Martin Rush Multibeam 2 user manual

Chauvet EVE P-140VW user manual

Chauvet

Chauvet EVE P-140VW user manual

Chauvet Professional Ovation P-56FC user manual

Chauvet Professional

Chauvet Professional Ovation P-56FC user manual

ProLights ECLIPSEHDTWC user manual

ProLights

ProLights ECLIPSEHDTWC user manual

Chauvet EZpar T6 USB user manual

Chauvet

Chauvet EZpar T6 USB user manual

thomann STAIRVILLE Beam Moving Head B2R user manual

thomann

thomann STAIRVILLE Beam Moving Head B2R user manual

Varytec Studio Par Mini user manual

Varytec

Varytec Studio Par Mini user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.