Ledj FOLL010 User manual

Order code: FOLL010
FS 100 LED Followspot
User Manual

www.prolight.co.uk FS 100 LED Followspot User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE-
FULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk FS 100 LED Followspot User Manual
3
Product overview & technical specications
TheLEDJFS100Followspotfeatures6dichroiccoloursplusopencoldwhite,3200Kwarmwhitelter,an
electronicshutterforinstantaneousblackout,a9°-14°beamangle,manualfocusing,manualirisandrear
positioninghandle.OnboardDMXcontrolalsogivestheusertheexibilitytocontrolthedimmer,shutterand
colourwheelfromaDMXlightingconsole.
•1x100WcoolwhiteLED
•Adjustablebeamangle:9°-14°
•15kHzrefreshrate
•Manualfocus&zoom
•Electronicblackout
•Manualiris
•Colourwheel:7dichroiccolours,3200K,red,
yellow,blue,green,purplepink+open
•DMXchannels:2
•0-100%dimming
•Rearpositioninghandle
•3pushbuttonmenuwithLEDdisplay
•PowerCONinput
•3-PinXLRinput/output
•Fancooled
FS 100 LED Followspot
Specications
Powerconsumption 118W
Powersupply 100~240V,50/60Hz
Fuse F2A250V
Dimensions 270x280x585mm
Weight 6.4kg
Ordercode FOLL010
0m 3m 5m 7m 8m
9° - Lux
14° - Lux
3930
2260
1m
35600
18090
1300
810
14°
710
412
583
310
9°
585mm280mm
270mm

www.prolight.co.uk FS 100 LED Followspot User Manual
4
www.prolight.co.uk
FOCUS
ZOOM
IRIS
ON
OFF
POWER INPUT:
100-240V~50/60Hz
FUSE:
F2A 250V
100W LED FOLLOWSPOT
DOWN
FUNCTION SELECT
OPEN
COOL
WHITE
WARM
WHITE RED YELLOW
BLUE GREEN PURPLE PINK
BLACKOUT
SHUTTER
• DMX MODE
• MANUAL MODE
UP
Technical specications
01-Dimmingknob
02-DMXinput
03-DMXoutput
04-Colourbuttons
05-Shutterbuttons
06-LEDdisplay
07-Functionbuttons
08-PowerCONinput
09-Fuse:F2A250V
10-On/Offswitch
11-Earthpoint
12-Zoom
13-Focus
14-Iris
Inthebox:1 x xture,
1 x power cable &
1 x user manual
04 07 09
10
11
13
14
05 06 08 12
DMX INPUT
DMX OUTPUT
DIMMING
MIN MAX
DMX INPUT
DMX OUTPUT
DIMMING
MIN MAX
03 02
01

www.prolight.co.uk FS 100 LED Followspot User Manual
5
Operating instructions
Functions:
Dimmer-Turnclockwisetoincreasetheintensity,andanti-clockwisetodecreasetheintensity.
Shutter-TheLEDdisplaywillshowonwhentheshutterisopenandofFwhentheshutterisclosed.
Colourbuttons-Allowstheusertochoosebetween6coloursplus3200Kandopen.
Functionselectionbutton-UsethisbuttontoswitchbetweenDMXandManualmodes
(ModeisindicatedbyLEDsabovedisplay)
LEDdisplay/StatusLEDs-TheLEDdisplayshowstheDMXaddressandxturestatus.ThestatusLEDs
showtheuserwhethertheunitisinDMXorManualmodesandwhetheritisreceivingaDMXsignal.
Up/downbuttons-TheseareusedtochangetheDMXaddress.
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomesto
customisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthexture
andeachxtureindependently.
ToaccesstheDMXmode,pressthe“FUNCTION SELECT”buttonontherearoftheunittoshow--1on
theLEDdisplayandtheDMXmodeLEDisilluminated.TheunitisnowinDMXmode.Nowusethe“UP”
and“DOWN”buttonstosetthedesiredDMXaddress.
Manual mode:
Toaccessthemanualmode,pressthe“FUNCTION SELECT”buttonontherearoftheunituntilthe
ManualmodeLEDisilluminated.Theunitisnowinmanualmode.Nowusetheshutterandcolour
buttonsalongwiththedimmingknobtocontroltheunit.
Channel Value Function
1 000-031 Open(coolwhite)
032-063 3200K
064-095 Red
096-127 Yellow
128-159 Blue
160-191 Green
192-223 Purple
224-255 Pink
2000-255 Masterdimmer(0-100%)
2 channel mode:

www.prolight.co.uk FS 100 LED Followspot User Manual
6
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-512.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk FS 100 LED Followspot User Manual
7
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterferance.itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk FS 100 LED Followspot User Manual
8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
Table of contents
Popular Home Lighting manuals by other brands

Safavieh Lighting
Safavieh Lighting TORI TBL4014A manual

Safavieh
Safavieh LIT4034A manual

JONATHAN Y
JONATHAN Y JYL2022A quick start guide

Safavieh Lighting
Safavieh Lighting TBL4416A quick start guide

Dale Tiffany
Dale Tiffany TT10346 Assembly instructions

Philips
Philips myLiving 45938/31/16 Specification sheet

Safavieh Lighting
Safavieh Lighting TBL4262 quick start guide

ACME
ACME CM-600Z II user manual

nordlux
nordlux FRIDA Mounting instruction

De Projectinrichter
De Projectinrichter BELLEVUE AJ3 User instructions

Philips
Philips myLiving 36336/31/16 Specifications

Philips
Philips myLiving 37481/30/16 Specifications