Installer: Manual must
remain with owner/operator.
Prior to installation, record information
from pump nameplate for future reference:
Model:
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 1-800-543-2550
fax: 1-585-494-1839
www.LibertyPumps.com
Keep this manual handy for future reference.
For replacement manual, visit LibertyPumps.com,
or contact Liberty Pumps at 1-800-543-2550.
Retain dated sales receipt for warranty.
Serial:
Mfg Date:
Install Date:
Installation Manual 7035000R
Copyright © Liberty Pumps, Inc. 2021
All rights reserved.
Submersible Dewatering/Effluent Pumps
Models
250-Series 1/3 hp
280-Series 1/2 hp
290-Series 3/4 hp
FL30-Series 1/3 hp
FL50-Series 1/2 hp
FL60-Series 6/10 hp
FLH60-Series 6/10 hp
FL70-Series 3/4 hp
FL100-Series 1hp
FL150-Series 1-1/2 hp
FL200-Series 2hp
2 | EN Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7035000R
Contents
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 | EN
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Operating Constraints . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Model Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Inspection and Storage. . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Pump Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Pump System Components . . . . . . . . . . . . . . . . . . . . . 5 | EN
Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 | EN
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 | EN
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 | EN
Maintenance and Troubleshooting . . . . . . . . . . . . . . . 9 | EN
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 | EN
Safety Guidelines
Safety Precautions
Accidental contact with electrically live parts, items, fluid, or
water can cause serious injury or death.
Always disconnect pump(s) from power source(s) before
handling or making any adjustments to either the pump(s),
the pump system, or the control panel.
All installation and maintenance of pumps, controls,
protection devices, and general wiring shall be done by
qualified personnel.
All electrical and safety practices shall be in accordance with
the National Electrical Code®, the Occupational Safety and
Health Administration, or applicable local codes and
ordinances.
Do not remove cord and strain relief, and do not connect
conduit to pump.
Pump shall be properly grounded using its supplied
grounding conductor. Do not bypass grounding wires or
remove ground prong from attachment plugs. Failure to
properly ground the pump system can cause all metal
portions of the pump and its surroundings to become
energized.
Do not handle or unplug the pump with wet hands, when
standing on damp surface, or in water unless wearing
Personal Protective Equipment.
Always wear dielectric rubber boots and other applicable
Personal Protective Equipment (PPE) when water is on the
floor and an energized pump system must be serviced, as
submerged electrical connections can energize the water. Do
not enter the water if the water level is higher than the PPE
protection or if the PPE is not watertight.
Do not lift or carry a pump or a float assembly by its power
cord. This will damage the power cord, and could expose the
electrically live wires inside the power cord.
The electrical power supply shall be located within the length
limitations of the pump power cord, and for below grade
installations it shall be at least 4 ft (1.22 m) above floor level.
Do not use this product in applications where human contact
with the pumped fluid is common (such as swimming pools,
fountains, marine areas, etc.).
Protect the power and control cords from the environment.
Unprotected power and control (switch) cords can allow water
to wick through ends into pump or switch housings, causing
surroundings to become energized.
Single-phase 208/230V pumps shall only be operated without
the float switch by using the circuit breaker or panel
disconnect.
Some products may have internal capacitors that could cause
shock. Avoid contact with plug ends after removing from
energy source.
Do not use metal or any other electrical conducting material
to raise the float or contact anything inside an electrically live
sump pit.
This safety alert symbol is used in the manual
and on the pump to alert of potential risk for
serious injury or death.
This safety alert symbol identifies risk of
electric shock. It is accompanied with an
instruction intended to minimize potential
risk of electric shock.
This safety alert symbol identifies risk of fire.
It is accompanied with an instruction
intended to minimize potential risk of fire.
This safety alert symbol identifies risk of
serious injury or death. It is accompanied
with an instruction intended to minimize
potential risk of injury or death.
Warns of hazards which if not avoided will
result in serious injury or death.
Warns of hazards which if not avoided could
result in serious injury or death.
Warns of hazards which if not avoided could
result in minor or moderate injury.
Signals an important instruction related to
the pump. Failure to follow these instructions
could result in pump failure or property
damage.
Read every supplied manual before using
pump system. Follow all the safety
instructions in manual(s) and on the pump.
Failure to do so could result in serious injury
or death.
RISK OF ELECTRIC SHOCK
7035000R Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 3 | EN
Do not use an extension cord to power the product. Extension
cords can overload both the product and extension cord
supply wires. Overloaded wires will get very hot and can catch
on fire.
This product requires a separate, properly fused and
grounded branch circuit, sized for the voltage and amperage
requirements of the pump, as noted on the nameplate.
Overloaded branch circuit wires will get very hot and can
catch on fire. When used, electrical outlets shall be simplex of
the appropriate rating.
For cord replacement: power cord must be of the same length
and type as originally installed on the Liberty Pumps product.
Use of incorrect cord may lead to exceeding the electrical
rating of the cord and could result in death, serious injury, or
other significant failure.
Do not use this product with or near flammable or explosive
fluids such as gasoline, fuel oil, kerosene, etc. If rotating
elements inside pump strike any foreign object, sparks may
occur. Sparks could ignite flammable liquids.
Sewage and effluent systems produce and may contain
flammable and explosive gases. Prevent introduction of
foreign objects into basin as sparks could ignite these gases.
Exercise caution using tools and do not use electronic devices
or have live, exposed electrical circuits in or around basins,
open covers and vents.
Manual pumps that have been factory constructed with a
power cord with no male attachment plug must use an
approved motor control panel. Do not wire a switch in series
with the pump power cord as this can overload the wires.
Overloaded wires get very hot and can catch on fire.
These pumps are not to be installed in locations classified as
hazardous in accordance with the National Electric Code®,
ANSI/NFPA 70.
Energizing the control panel or breaker for the first time is
potentially dangerous. Licensed electrical personnel should
be present when the panel or breaker is energized for the first
time. If faults caused by damage or poor installation practices
have not been detected, serious damage, injury or death can
result when power is applied.
Do not modify the pump/pump system in any way.
Modifications may affect seals, change the electrical loading
of the pump, or damage the pump and its components.
All pump/pump system installations shall be in compliance
with all applicable Federal, State, and Local codes and
ordinances.
Do not allow children to play with the pump system.
Do not allow any person who is unqualified to have contact
with this pump system. Any person who is unaware of the
dangers of this pump system, or has not read this manual, can
easily be injured by the pump system.
In 208/230V installations, one side of the line going to the
pump is always “hot”, whether the float switch is on or off. To
avoid hazards, install a double pole disconnect near the pump
installation.
Vent basin in accordance with local code. Proper venting of
sewer and effluent gases alleviates poisonous gas buildup
and reduces the risk of explosion and fire from these
flammable gases.
Wear adequate Personal Protective Equipment when working
on pumps or piping that have been exposed to wastewater.
Sump and sewage pumps often handle materials that can
transmit illness or disease upon contact with skin and other
tissues.
Do not enter a pump basin after it has been used. Sewage and
effluent can emit several gases that are poisonous.
Do not remove any tags or labels from the pump or its cord.
Keep clear of suction and discharge openings. To prevent
injury, never insert fingers into pump while it is connected to
a power source.
Do not use this product with flammable, explosive, or
corrosive fluids. Do not use in a flammable and/or explosive
atmosphere as serious injury or death could result.
This product contains chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. www.p65warnings.ca.gov.
This pump has been evaluated for use with water only.
Verify 3-phase pumps for correct rotation prior to installing
pump(s) in basin. To change rotation, reverse any two of the
three power leads to the pump (not the ground). Code the
wires for reconnection after installation.
Do not dispose of materials such as paint thinner or other
chemicals down drains. Doing so could chemically attack and
damage pump system components and cause product
malfunction or failure.
Do not use pumps with fluid over 140°F (60°C). Operating the
pump in fluid above this temperature can overheat the pump,
resulting in pump failure.
Do not use pump system with mud, sand, cement,
hydrocarbons, grease, or chemicals. Pump and system
components can be damaged from these items causing
product malfunction or failure. Additionally, flooding can
occur if these items jam the impeller or piping.
Do not introduce any consumer item that is not toilet paper
into a non-grinder (dewatering/effluent or sewage) pump/
pump system. This includes, but is not limited to the
following: feminine products, wipes, towels, towelettes, dental
floss, swabs, pads, etc. Items such as these put the pump
under undo strain and can result in pump/pump system
failure. Additionally, it creates conditions for discharge line
blockage.
Submersible Pump—do not run dry
Do not exert heavy pressure or run heavy equipment on the
backfill material as this could cause the tank to collapse.
RISK OF FIRE
RISK OF SERIOUS INJURY OR DEATH
4 | EN Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7035000R
Do not position the pump float directly under the inlet from
drain tile or in the direct path of any incoming water.
Keep pump upright.
Do not allow pump to freeze.
At no time shall the pump be stored within an incomplete wet
basin. The pump shall not be placed into the basin until it can
be fully operational.
Effluent pumps need to be totally submerged below the water
line to prevent pump corrosion.
Model Specifications
For complete listing of models and their specifications, refer to
http://www.LibertyPumps.com/About/Engineering-Specs. Pump
nameplate provides a record of specific pump information.
Inspection and Storage
Initial Inspection
Inspect pump immediately for damage that may have occurred in
shipment.
1. Visually check the pump and any spare parts for damage.
2. Check for damaged electrical wires, especially where they exit
the motor housing.
Contact Liberty Pumps customer service to report any damage or
shortage of parts.
Storage Before Use
Protect the power and control cords from the environment.
Unprotected power and control (switch) cords can allow water
to wick through ends into pump or switch housings, causing
surroundings to become energized.
At no time shall the pump be stored within an incomplete wet
basin. The pump shall not be placed into the basin until it can
be fully operational.
Do not allow the pump to freeze.
Pumps are shipped from the factory ready for installation and use.
Hold the pump in storage if the pump station is not complete.
If storage is necessary, the pump should remain in its shipping
container. It should be stored in a warehouse or storage shed that
has a clean, dry temperature-stable environment where the pump
and its container are covered to protect it from water, dirt,
vibration, etc. The cord ends must be protected against moisture.
Uninstalled pumps that are idle for greater than three months
should have impellers manually rotated once a month to lubricate
the seals.
Installed pumps that are idle for greater than one month should
have impellers manually operated through the breaker panel once
a month to lubricate the seals. For automatic models, turn off the
breaker, unplug the piggyback switch, and plug the pump directly
into the wall socket. Turn the breaker on for 30 seconds, then turn
the breaker off. Plug the piggyback switch back in. Refer to
Piggyback Switch Operation on page 7.
Pumps that are idle in a wet basin must be removed.
Pump Design
All Liberty Pumps dewatering/effluent pumps come equipped
with an air bleed hole in the base of the pump to help prevent
airlock. A small spray of water from this hole is normal while pump
is running.
For added protection, consider the addition of a back-up pump,
as well as an alarm in applications where loss of pump function
could result in property damage. If an alarm is used, it must be
connected to a separate electrical circuit.
General Information
Before installation, read these instructions carefully. Each
pump is individually factory tested to ensure proper
performance. Closely following these instructions will
eliminate potential operating problems, assuring years of
trouble-free service.
These pumps are to be used for handling septic tank
effluent and drain (storm) water.
Provide pump serial number in all correspondence.
Pumps are certified to CSA® and UL® standards.
Pumps must be serviced at a qualified repair facility
approved by Liberty Pumps. No repair work should be
carried out during the warranty period without prior factory
approval. Any unauthorized field repairs void warranty.
Contact Liberty Pumps at 1-800-543-2550 to locate the
closest authorized service center.
Operating Constraints
It is extremely important to verify that the pump has been
sized correctly for the intended installation. The operating
point of the pump must lie within the acceptable range as
outlined by the applicable Liberty Pumps performance chart.
Operating the pump outside of the recommended range
can invalidate the CSA Certification of the pump and can
also cause damage and premature failure. Operating
outside of the recommended range can cause the pump to
exceed its rated nameplate amp draw, which will void the
pump certification. It can also cause motor overheating,
cavitation, excessive vibration, clogging, and poor energy
efficiency.
RISK OF ELECTRIC SHOCK
7035000R Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 5 | EN
Pump System Components
Control Panel
Manual models (“M” suffix) and 3-phase models require a
separate, approved pump control device or panel for automatic
operation. Operation will be according to the control panel
selected. Refer to separate manufacturer’s instructions supplied
with the unit. Verify the electrical specifications for the control
panel properly match those of the pump. 3-phase models require
overload elements selected or adjusted in accordance with the
control or panel instructions.
Mounting, installation, and wiring connections are specific to the
control panel used. Refer to the manufacturer’s instructions
supplied with the unit.
IMPORTANT: When connecting a new pump to an existing
control panel, verify the panel is correctly sized and equipped for
the pump.
Control panels designed for use with specific pumps available
from Liberty Pumps can be found at http://
www.LibertyPumps.com/Portals/0/Files/panel_selection_guide.pdf
or contact Liberty Pumps.
Float Switches
Single-phase 208/230V pumps shall only be operated without
the float switch by using the circuit breaker or panel
disconnect.
Automatic Models
All FL-Series automatic models (“A” suffix) and Models 253, 283
and 293 come factory-equipped with a float switch mounted to
the pump. These models come with two cords—one to the float
switch and the other to the pump motor. The switch cord has a
series (piggyback) plug enabling the pump motor cord to be
plugged into the back of it. The purpose of this design is to allow
temporary manual operation of the pump.
For manual operation, or in the event of float switch failure, the
pump cord can be separated and plugged into the electrical
outlet, directly bypassing the switch. Refer to Piggyback Switch
Operation on page 7.
If using a differential other than the factory setting, verify that
when the pump turns off, the minimum fluid level left in the basin
is per Table 1 so the impeller remains submerged. A minimum
cord length of 3-1/2” from the tether point to the top surface of
the float is required for proper switch operation.
Models 251, 257, 281, 287, 291, and 297 have factory-preset float
switches that are not adjustable. Other pumping differentials may
be obtained by tethering the switch cord to the discharge pipe.
Switchless (Manual) Models
Manual pumps with no float switch are intended to be run using
an approved liquid level control or approved motor control with
correct rating that matches motor input in full load amperes.
Regardless of the control type, verify that when the pump shuts
off, the minimum fluid level left in the basin is per Table 1 so the
impeller remains submerged.
IMPORTANT: Manual pumps factory constructed with a power
cord with no male attachment plug must use an approved motor
control panel. Do not wire a switch in series with the pump power
cord.
Automatic operation with optional control devices: if the
pump(s) are to be operated by either a simplex or duplex control
panel or other optional control device, follow the manufacturer’s
instructions provided with the control panel for power
connections.
Float Switch Settings
Table 1 includes factory set float levels for automatic models. The
turn OFF level must be maintained as it is the minimum water
depth to ensure proper cooling. Manual pumps have user-set turn
ON levels.
RISK OF ELECTRIC SHOCK
Table 1. Factory Set Float Switch Settings
Model Turn OFF Level Turn ON Level
250 4” user-set
251, 253 4” 11”
257 4” 7”
280 4” user-set
281, 283 7” 13”
287 4” 9.5”
290 4” user-set
291, 293 7” 13”
297 4” 9.5”
FL30 5” 12”
FL50 6” 13”
FL60 6” 13”
FL70 6” 13”
FLH60 6” 13”
FL100 8” 15”
FL150 8” 15”
FL200 8” 15”
6 | EN Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7035000R
Preparation
Always disconnect pump(s) from power source(s) before
handling or making any adjustments to either the pump(s),
the pump system, or the control panel.
The basin required for effluent applications must be sealed and
vented to meet health and plumbing code requirements. Proper
basin size and materials for effluent applications vary depending
on the type of effluent system and local codes. Check local codes
prior to purchasing and installing the basin. Follow the
manufacturer's recommended guidelines for installation of the
basin. A minimum diameter of 18" and depth of 24" is required for
proper pump operation, but larger basins are preferred for longer
pump cycles and increased float switch life. Installation should be
at a sufficient depth to ensure that all plumbing is below the frost
line. If this is not feasible, size the basin and/or adjust the pump
differential to accommodate the additional backflow.
For ordinary ground water pumping applications, it is
recommended that the sump basin diameter be a minimum of
14”. Vertical Magnetic Float (VMF) models 257, 287, and 297 may
be used in a minimum 10” diameter sump; however, a larger
diameter basin is preferred as it allows for a longer pump cycle
and reduced float switch cycling. The depth of the basin should be
a minimum of 18”.
Prepare Existing Sump [Basin]
If replacing a previously installed pump, prepare the basin by
removing the old pump and cleaning any debris from the basin.
Inspect all remaining equipment in the basin including piping,
valves, and electrical junction boxes (if present) and repair or
replace as appropriate.
If the basin is not already enclosed on the bottom, provide a hard
level bottom of bricks or concrete. Do not place the pump directly
on earth, gravel, or debris since this can cause excessive wear of
the impeller and possible jamming.
“The Brick” (Liberty Pumps #4445000) is a pre-molded stable
platform designed to fit the 250, 280, and 290-Series submersible
pumps. It raises the pump 2-1/2” off the bottom of the basin,
reducing the potential for jamming from rocks and debris. Contact
a local distributor to order.
Prepare New Sump [Basin]
Excavation
Locate all overhead and underground utilities before
excavating.
Excavate the hole as small as possible, with a minimum
recommended 8” diametrical clearance around the tank. Never
place the basin directly in contact with rocks or other sharp
objects. Place only fine, 1/8” to 3/4” pea gravel or 1/8” to 1/2”
washed, crushed stone as bedding between the basin and the
hole walls.
Do not use sand or native soil as backfill. Properly compact
underneath the basin to provide a solid, level base that can
support the weight of the filled basin.
Inlet Connection & Initial Backfill
Use only fine, 1/8” to 3/4” pea gravel or 1/8” to 1/2” washed,
crushed stone around the bottom of the basin to hold it in place.
Do not use sand or native soil as backfill.
Make the inlet connection as required per basin.
Final Backfill
Do not exert heavy pressure or run heavy equipment on the
backfill material as this could cause the tank to collapse.
Keep large rocks, clods, and foreign objects out of the backfill
material. Only fine, 1/4” to 3/4” pea gravel, or 1/8” to 1/2” washed,
crushed stone is recommended. Do not use sand or native soil as
backfill. Mound the backfill slightly and allow for natural settling.
Provide access to the basin cover for maintenance and service.
Compaction of backfill materials must be adequate to ensure the
support of the tank, and to prevent movement or settlement.
Installation
All installation and maintenance of pumps, controls,
protection devices, and general wiring shall be done by
qualified personnel.
All electrical and safety practices shall be in accordance with
the National Electrical Code®, the Occupational Safety and
Health Administration, or applicable local codes and
ordinances.
Electrical Connections
With main power disconnected, complete pump and control
wiring connections per manufacturer’s wiring diagrams included
with the control panel as applicable. Check all wires for
unintentional grounds after the connections are made.
Guide Rail System
If guide rails are used, refer to the separate instructions supplied
with the unit for proper installation and operation, making sure all
gaskets and components are present. Liberty Pumps Guide Rail
System features a self-aligning mounting bracket. Contact Liberty
Pumps for available models, such as GR22 and GR30 for FL-Series
models.
If guide rails are not used, complete all pump-mounted plumbing
at this time, being sure all gaskets and components are present.
Pump
Record information from pump nameplate onto cover of these
instructions. Complete a visual inspection before lowering into
basin.
RISK OF ELECTRIC SHOCK
RISK OF SERIOUS INJURY OR DEATH
RISK OF ELECTRIC SHOCK
7035000R Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7 | EN
3-Phase Pump Rotation Verification
Check 3-phase pumps for correct rotation prior to installing
pump(s) in basin. To change rotation, reverse any two of the
three power leads to the pump (not the ground). Code the
wires for reconnection after installation.
3-phase power uses three separate
alternating currents that peak at
different integrals. With pumps that
are powered by three phase electric,
the phase sequence of the motor
must match the phase sequence of
the power source. When the phase
sequences match, the pump operates
properly.
However, when the phases are out of
order, the pump runs backward (i.e., the impeller rotates in the
wrong direction). This causes an extreme loss of performance and
could raise the current draw, which could result in tripping an
overload or circuit breaker.
To ensure that the power to the pump is installed correctly, always
verify proper rotation before lowering it into the basin. If the
pump is rotating in the wrong direction, turn off the power and
reverse any two leads to the pump (not ground). This reverses the
phase sequence and corrects the pump rotation. For 3-phase
pumps, rotation must be counterclockwise when looking from the
bottom of the pump. Label the wires for reconnection after
installation.
Automatic Pump Direct Wiring
In 208/230V installations, one side of the line going to the
pump is always “hot”, whether the float switch is on or off. To
avoid hazards, install a double pole disconnect near the pump
installation.
If a 1-phase pump will be wired directly into a junction box, and it
is necessary to remove the plug, a certified electrician shall
complete the wiring in accordance with the National Electric Code
and applicable local codes. A disconnecting means for the pump
shall be located in sight from the pump/basin location. See
Figure 1 for direct wire installation of 1-phase, automatic pumps.
Figure 1. Direct Wiring of 115 V or 208/230 V, 1-Phase, Automatic
Discharge
A check valve is required to prevent the backflow of liquid after
each pumping cycle. A gate valve should follow the check valve to
allow periodic cleaning of the check valve or removal of the pump.
The remainder of the discharge line should be as short as possible
with a minimum number of turns to minimize friction head loss.
Do not reduce the discharge to below that which is provided
on the pump. Larger pipe sizes may be required to eliminate
friction head loss over long runs. Contact Liberty Pumps or other
qualified person if questions arise regarding proper pipe size and
flow rates.
Check valve usage requires
drilling an 1/8” anti-airlock
hole in the discharge pipe
just above the pump’s
discharge outlet to prevent
pump airlock. Water spray
from this hole is normal.
Vent
Vent basin in accordance with applicable plumbing codes.
Piggyback Switch Operation
Single-phase 208/230V pumps shall only be operated without
the float switch by using the circuit breaker or panel
disconnect.
IMPORTANT: Verify breaker is turned off before plugging in the
switch.
Plug the piggyback switch into the receptacle. The receptacle
must be wired to an appropriately sized breaker. Plug the pump
into the piggyback receptacle. Install the cable clamp (if supplied)
for strain relief.
Figure 2. Piggyback Switch Operation
RISK OF SERIOUS INJURY OR DEATH
BOTTOM VIEW
ROTATION
Ground
Black
Junction Box
Power
Supply
White
Float
Switch Pump
Green
Black
White
Green
Black
White
RISK OF ELECTRIC SHOCK
Drill 1/8” anti-
airlock hole into
DISCHARGE PIPE
Discharge pipe
Temporary Manual
O
p
eration
YES!NO!
Install cable
clamp to wall
for strain relief
Temporary Manual
O
p
eration
YES!NO!
8 | EN Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7035000R
Dewatering/Sump System Application
A securable sump basin cover is required for safety and to prevent
foreign objects from entering the basin.
Figure 3. Typical Sump Installation (variations may apply)
1. Place pump in basin making certain the mounting interface
(i.e., guide rail, torque stop) is engaged correctly. Float switch
must have adequate clearance to side wall of basin and free,
unobstructed movement throughout its complete travel and
must not contact the pump, piping, or other objects.
A 1-1/2” threaded discharge is provided for connection of the
discharge pipe. Do not restrict the discharge to below that
which is provided on the pump. Schedule 40 PVC pressure
pipe is recommended.
2. Connect discharge pipe to the discharge of the pump.
Hand-tighten only. Over-tightening may cause the pump
housing to crack.
3. Install a union or other means of separating the discharge line
just above the floor to facilitate removal of the pump when
necessary. A check valve is required just above or in place of
the union to prevent the backflow of water after each pump
cycle.
4. Connect additional piping as needed to direct the discharge
to the desired location. Discharge should be kept as short as
possible with a minimum number of turns.
5. Check all connections.
Effluent System Application
VMF models (257, 287, and 297) are not recommended for
effluent applications due to their short ON/OFF cycle. Wide-angle
float models are better suited for effluent applications and are
easily adjustable for different ON/OFF levels.
A securable basin cover is required for safety and to prevent
foreign objects from entering the basin.
Simplex (One Pump) Systems
Effluent pumps need to be totally submerged below the water
line to prevent pump corrosion.
Figure 4. Typical Simplex System Installation (variations may apply)
1. Place pump in basin making certain the mounting interface
(i.e., guide rail, torque stop) is engaged correctly. Float switch
must have adequate clearance to side wall of basin and free,
unobstructed movement throughout its complete travel and
must not contact the pump, piping, or other objects.
2. If an optional control device or float is used, follow the
separate manufacturer’s directions for mounting. Minimum
pump turn OFF level must not be set below Table 1 values.
3. Connect the discharge pipe to the pump's threaded
discharge. Do not reduce the discharge pipe size below that
which is provided on the pump.
4. Install the remaining discharge line.
5. Install a union to facilitate pump removal when necessary.
6. Install a check valve after the union to prevent the backflow of
liquid after each pumping cycle.
7. Install a gate valve after the check valve to allow periodic
cleaning of the check valve or removal of the pump.
8. Install the remainder of the discharge line as short as possible
with a minimum number of turns to minimize friction head
loss. Larger pipe sizes may be required to eliminate friction
head loss over long runs. Contact Liberty Pumps or other
qualified person if there are questions regarding proper pipe
size and flow rates.
9. Mount and properly seal the basin cover.
10. Vent basin in accordance with applicable plumbing codes.
Inlet
Discharge
Inlet
Vent Stack (optional)
Electrical
Conduit
Union
Check Valve
Gate Valve
Discharge
7035000R Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 9 | EN
Duplex (Two Pump) Systems
Effluent pumps need to be totally submerged below the water
line to prevent pump corrosion.
Figure 5. Typical Duplex System Installation (variations may apply)
1. Place both pumps in basin, making certain the mounting
interface (i.e., guide rail, torque stop) is engaged correctly.
The duplex control used will include 3 or 4 floats that will
either be tethered to one of the discharge pipes or to an
independent rod or bracket. Follow the duplex control
manufacturer’s instructions provided with the device. Each
float switch must have adequate clearance to side wall of
basin and free, unobstructed movement throughout its
complete travel and must not contact the pump, piping, or
other objects. Minimum pump turn OFF level must not be set
below Table 1 values.
2. Connect an individual discharge pipe to each pump. Do not
reduce the discharge pipe size below that which is provided
on the pump. Larger pipe sizes may be required in some
applications to reduce friction head loss over long runs.
Contact Liberty Pumps or other qualified person if there are
questions regarding proper pipe size and flow rates.
3. Install unions or flexible connectors to facilitate removal of
the pump if necessary.
4. Install check valves on each discharge after the union and
prior to the gate valve to prevent the back flow of liquid or
gas. A check valve on each discharge line, prior to tying into
one common line, is necessary to prevent the recycling of
fluid from one pump to the other. A gate valve is
recommended after the check valve to allow for periodic
cleaning of the check valve or removal of the pump.
Depending on the height of the basin, the check valves may
either be installed inside the basin or outside the basin.
5. Install the remainder of the discharge line as short as possible
with a minimum number of turns to minimize friction head
loss. Larger pipe sizes may be required to eliminate friction
head loss over long runs. Contact Liberty Pumps or other
qualified person if there are questions regarding proper pipe
size and flow rates.
6. Mount and properly seal the basin cover.
7. Vent basin in accordance with applicable plumbing codes.
Operation
Energizing the control panel or breaker for the first time is
potentially dangerous. Licensed electrical personnel should
be present when the panel or breaker is energized for the first
time. If faults caused by damage or poor installation practices
have not been detected, serious damage, injury or death can
result when power is applied.
Starting System
1. Verify all plumbing components are installed correctly and
functional. Verify all valves are open and ready for pump use.
2. Double check all wire connections. Re-tighten all factory and
field connections.
3. Ensure pump has no obstructions.
4. With all electrical and mechanical connections complete and
secure, turn on power to pump and control panel, if
applicable.
5. Verify operation of the pump, floats, and alarm circuits.
6. Run several cycles of water through the system to verify
correct control operation for the installation.
Be certain to complete adequate testing, especially on systems
with multiple pumps or custom control configurations.
Maintenance and Troubleshooting
Accidental contact with electrically live parts, items, fluid, or
water can cause serious injury or death.
Always disconnect pump(s) from power source(s) before
handling or making any adjustments to either the pump(s),
the pump system, or the control panel.
Wear adequate Personal Protective Equipment when working
on pumps or piping that have been exposed to wastewater.
Sump and sewage pumps often handle materials that can
transmit illness or disease upon contact with skin and other
tissues.
Do not enter a pump basin after it has been used. Sewage and
effluent can emit several gases that are poisonous.
Inlet Discharge
Vent Stack (optional)
Electrical
Conduit
Union
Check
Valve
Gate
Valve
Control
Floats
RISK OF SERIOUS INJURY OR DEATH
RISK OF ELECTRIC SHOCK
RISK OF SERIOUS INJURY OR DEATH
10 | EN Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7035000R
Verify correct 3-phase pump rotation before retuning to
service.
Maintenance
As the motor is oil-filled, no lubrication or other maintenance is
required. Severe operating environments will require more
frequent checks. For any issues that are not resolvable, contact
Liberty Pumps for further assistance.
In the event the pump becomes clogged, the inlet screen can be
removed to gain access to the pump impeller. Once the
obstruction is removed, the anti-airlock hole should be cleaned.
To keep the pump/pump system operating smoothly, perform the
following routine checks:
Monthly
1. Pumps that are idle for more than a month in a dry basin
should have impellers manually operated through the breaker
panel monthly to lubricate the seals.
2. Pumps that are idle in a wet basin must be removed.
Quarterly
1. Check pumps for corrosion and wear.
2. Check for free and unobstructed float switch operation and
float switch condition.
3. Inspect for proper check valve operation.
4. For multiple pumps, check for balanced operating times.
Uneven times indicate a defective unit, float switch or control.
5. Inspect the control panel for any presence of moisture in
enclosure, loose connections, and general component
condition.
Annually
1. Inspect and clean basin. Replace any defective components.
Troubleshooting
No repair work shall be carried out during the warranty period
without prior factory approval. To do so may void the warranty.
Liberty Pumps, Inc. assumes no responsibility for damage or injury
due to disassembly in the field. Disassembly, other than an
authorized repair facility approved by Liberty Pumps or its
authorized service centers, automatically voids warranty.
Refer to Table 2 for troubleshooting guidance.
Table 2. Troubleshooting Matrix
Problem Possible Cause Corrective Action
Pump does not start.
Damaged power or control cord. Replace as needed.
Control panel selector switch in OFF position. Set selector switch to Hand or Auto position.
Blown control circuit transformer fuse. Replace fuse.
Tripped circuit breaker, tripped GFCI, blown fuse,
or other interruption of power.
Reset tripped circuit breaker, reset GFCI, replace blown
fuse with properly sized fuse, check that the unit is
securely plugged in, investigate power interruption.
Improper voltage. Have an electrician check all wiring for proper
connections and adequate voltage and capacity.
Float switch unable to move to pump ON
position due to interference in basin or other
obstruction.
Position pump or float switch so that it has adequate
clearance for free movement.
Insufficient liquid level. Verify liquid level is allowed to rise enough to activate
float switch.
Defective float switch. Replace float switch.
Obstructed impeller or volute. Remove obstruction.
Loose wiring connections. Check and tighten all connections.
Pump cycles too
frequently.
Improper float switch setting. Adjust float switch setting.
Check valve not installed, stuck open, or leaking. Install check valve(s); remove check valve and examine
for freedom of operation and proper installation.
7035000R Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 11 | EN
Pump runs, but does
not turn off.
Pump is airlocked.
Turn pump off and let set for several minutes, then restart.
Control panel selector switch in Hand position. Set selector switch to Auto position.
Float switch unable to move to pump OFF
position due to interference with the side of
basin or other obstruction.
Position pump or float switch so that it has adequate
clearance for free movement.
Control panel failure. Check control panel.
Defective float switch. Replace float switch.
Pump runs or hums, but
does not pump.
Discharge line blocked or restricted. Check discharge line for foreign material, including ice if
discharge line passes through or into cold areas.
Check valve is stuck closed or installed backward. Remove check valve(s) and examine for freedom of
operation and proper installation.
Gate or ball valve is closed. Open gate or ball valve.
Total head is beyond pump's capability. Route piping to a lower level. If not possible, a larger
pump may be required. Consult Liberty Pumps.
Obstructed impeller or volute. Remove obstruction.
Pump is airlocked.
Turn pump off and let set for several minutes, then restart.
Add baffle to reduce trapped air bubbles.
Pump runs periodically
when fixtures are not in
use.
Check valve not installed, stuck open, or leaking. Install check valve(s); remove check valve and examine
for freedom of operation and proper installation.
Fixtures are leaking. Repair fixtures as required to eliminate leakage.
Pump does not deliver
proper capacity.
Discharge valve(s) partially closed or clogged. Check the discharge line for foreign material, including
ice if the discharge line passes through or into cold areas.
Check valve partially clogged. Raise liquid level up and down to clear; remove check
valve to remove obstruction.
Incorrect motor rotation.
1-Phase: Consult factory.
3-Phase: Correct 3-phase pump rotation direction. Refer
to section 3-Phase Pump Rotation Verification.
Total head is beyond pump's capability. Route discharge piping to a lower level. If not possible, a
larger pump may be required. Consult Liberty Pumps.
Low liquid level. Check liquid level.
Obstruction in pump or piping. Remove obstruction.
Pump operates noisily.
Piping attachments to building are too rigid. Replace a portion of the discharge line with rubber hose
or connector.
Incorrect motor rotation.
1-Phase: Consult factory.
3-Phase: Correct 3-phase pump rotation direction. Refer
to section 3-Phase Pump Rotation Verification.
Foreign objects in the impeller cavity. Clean the impeller cavity.
Broken impeller. Consult Liberty Pumps for information regarding impeller
replacement.
Table 2. Troubleshooting Matrix (continued)
Problem Possible Cause Corrective Action
12 | EN Copyright © Liberty Pumps, Inc. 2021
All rights reserved. 7035000R
Warranty
Liberty Pumps Wholesale Products Limited Warranty
Liberty Pumps, Inc. warrants that Liberty Pumps wholesale products are free from all factory defects in material and workmanship for a
period of three (3) years from the date of purchase (excluding* batteries and “Commercial Series” models). The date of purchase shall be
determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must accompany the
returned pump if the date of return is more than three years from the date of manufacture noted on the pump nameplate.
The manufacturer's sole obligation under this Warranty shall be limited to the repair or replacement of any parts found by the
manufacturer to be defective, provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service
center, and provided that none of the following warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the product has not been properly installed, operated, or maintained per
manufacturer instructions; if it has been disassembled, modified, abused, or tampered with; if the electrical cord has been cut, damaged,
or spliced; if the pump discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating;
if the pump has been used in water containing sand, lime, cement, gravel, or other abrasives; if the product has been used to pump
chemicals, grease, or hydrocarbons; if a non-submersible motor has been subjected to moisture; or if the label bearing the model and
serial number has been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage, or expenses resulting from installation or use of its products, or for indirect,
incidental, and consequential damages, including costs of removal, reinstallation or transportation.
There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are
limited to three years from the date of purchase. This Warranty contains the exclusive remedy of the purchaser, and, where
permitted, liability for consequential or incidental damages under any and all warranties are excluded.
*Liberty Pumps, Inc. warrants StormCell®batteries for 1 year from date of purchase, and warrants that pumps of its Commercial Series
are free from all factory defects in material and workmanship for a period of 18 months from the date of installation or 24 months from
the date of manufacture, whichever occurs first, and provided that such products are used in compliance with their intended applications
as set forth in the technical specifications and manuals.
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 1-800-543-2550
fax: 1-585-494-1839
www.LibertyPumps.com
Repeated tripping.
Circuit protection underrated. Check rating and replace with proper size.
Other appliance on same circuit. Pump requires separate circuit.
Pump is connected to an extension cord or
wiring is inadequate or compromised. Have an electrician check for proper wiring.
Improper voltage. Have an electrician check all wiring for proper
connections and adequate voltage and capacity.
Obstruction in pump. Remove obstruction.
Incorrect motor rotation.
1-Phase: Consult factory.
3-Phase: Correct 3-phase pump rotation direction. Refer
to section 3-Phase Pump Rotation Verification.
Foreign matter buildup. Clean motor housing.
Table 2. Troubleshooting Matrix (continued)
Problem Possible Cause Corrective Action

This manual suits for next models

10

Other Liberty Pumps Water Pump manuals

Liberty Pumps Omnivore LSG Series User manual

Liberty Pumps

Liberty Pumps Omnivore LSG Series User manual

Liberty Pumps StormCell 442 Series User manual

Liberty Pumps

Liberty Pumps StormCell 442 Series User manual

Liberty Pumps SumpJet SJ10 User manual

Liberty Pumps

Liberty Pumps SumpJet SJ10 User manual

Liberty Pumps LEPS Series User manual

Liberty Pumps

Liberty Pumps LEPS Series User manual

Liberty Pumps SumpJet SJ10A User manual

Liberty Pumps

Liberty Pumps SumpJet SJ10A User manual

Liberty Pumps Ascent ASC-1 User manual

Liberty Pumps

Liberty Pumps Ascent ASC-1 User manual

Liberty Pumps SumpJet SJ10 User manual

Liberty Pumps

Liberty Pumps SumpJet SJ10 User manual

Liberty Pumps 404 User manual

Liberty Pumps

Liberty Pumps 404 User manual

Liberty Pumps Ascent ASC-1 User manual

Liberty Pumps

Liberty Pumps Ascent ASC-1 User manual

Liberty Pumps LE40 Series User manual

Liberty Pumps

Liberty Pumps LE40 Series User manual

Liberty Pumps HT450 Series User manual

Liberty Pumps

Liberty Pumps HT450 Series User manual

Liberty Pumps EPS User manual

Liberty Pumps

Liberty Pumps EPS User manual

Liberty Pumps XFL50 Series User manual

Liberty Pumps

Liberty Pumps XFL50 Series User manual

Liberty Pumps 2448 Series User manual

Liberty Pumps

Liberty Pumps 2448 Series User manual

Liberty Pumps LSG202M User manual

Liberty Pumps

Liberty Pumps LSG202M User manual

Liberty Pumps LCU Series User manual

Liberty Pumps

Liberty Pumps LCU Series User manual

Liberty Pumps Pro380 Series User manual

Liberty Pumps

Liberty Pumps Pro380 Series User manual

Liberty Pumps LGV Series User manual

Liberty Pumps

Liberty Pumps LGV Series User manual

Liberty Pumps Omnivore XLSG200 Series User manual

Liberty Pumps

Liberty Pumps Omnivore XLSG200 Series User manual

Liberty Pumps SPAC-237 User manual

Liberty Pumps

Liberty Pumps SPAC-237 User manual

Liberty Pumps XLE Series User manual

Liberty Pumps

Liberty Pumps XLE Series User manual

Liberty Pumps LCU-15 User manual

Liberty Pumps

Liberty Pumps LCU-15 User manual

Liberty Pumps XLGV02 Series User manual

Liberty Pumps

Liberty Pumps XLGV02 Series User manual

Liberty Pumps LGV02 Series User manual

Liberty Pumps

Liberty Pumps LGV02 Series User manual

Popular Water Pump manuals by other brands

Pentair Hydromatic S4S Installation and service manual

Pentair

Pentair Hydromatic S4S Installation and service manual

JABSCO 51510 Series manual

JABSCO

JABSCO 51510 Series manual

Goulds Pumps 3198 Installation, operation and maintenance manual

Goulds Pumps

Goulds Pumps 3198 Installation, operation and maintenance manual

Graco G3 Series instructions

Graco

Graco G3 Series instructions

Graco 226040 Instructions-parts list

Graco

Graco 226040 Instructions-parts list

Aqua Computer LEAKSHIELD installation manual

Aqua Computer

Aqua Computer LEAKSHIELD installation manual

Zoeller 109 Series manual

Zoeller

Zoeller 109 Series manual

Wilo Norma V Series Installation and operating instructions

Wilo

Wilo Norma V Series Installation and operating instructions

Briggs & Stratton PROSERIES 205378GS Operator's manual

Briggs & Stratton

Briggs & Stratton PROSERIES 205378GS Operator's manual

Hydronic P820 Installation, use and maintenance manual

Hydronic

Hydronic P820 Installation, use and maintenance manual

Pentair ISO PRO Installation, operation and maintenance manual

Pentair

Pentair ISO PRO Installation, operation and maintenance manual

Smiths Graseby 3200 Technical & service manual

Smiths

Smiths Graseby 3200 Technical & service manual

dosatron D9 Green Line Quick start-up

dosatron

dosatron D9 Green Line Quick start-up

Pfeiffer Vacuum ATH 1603 M operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum ATH 1603 M operating instructions

Wacker Neuson PST3 750 Operator's manual

Wacker Neuson

Wacker Neuson PST3 750 Operator's manual

LEO ACm60 instruction manual

LEO

LEO ACm60 instruction manual

SHG CHIEMSEE Series operating manual

SHG

SHG CHIEMSEE Series operating manual

iDM iPUMP A 2-7 installation instructions

iDM

iDM iPUMP A 2-7 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.