Specplus SPS2GFSVA2FT or 3FT
Page 2 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 or 3 Lamp, Twin Tube T5
Ord ring Information
Explanation of Catalog Number. Example: SPS2GFSVA3FTUNVIB
Options/Acc ssori s
Sp cial L ns s: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight
per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute S1 or S2 for VA (standard) =
Sky Acrylic Lens (see Sky Lens sell sheet for further
details).
Plast r Fram : Catalog Number: PF22.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Int rf r nc Filt r:
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Fusing: Internal fast-blow fusing. SUFFIX A.
Internal slow-blow fusing. SUFFIX C.
El ctrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).
Chicago Pl num: SUFFIX: C.
Sp cifications
P rformanc : In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .81. To prevent glare the VCP shall
be not less than 29 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 4447 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 66.5%.
Sp cifications (continu d)
Mat rials:Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails hemmed
over and housing ends turned-in for safe handling.
Finish:Chassis xt rior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
L ns s:VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. aver-
age weight per square foot.
El ctrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Lab ls: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Sp cplus:
Recessed
fluorescent
troffer
S
Static
2
Fixtur
Width
L ns Fram :
FS = Flat steel
frame.
RA= Regressed
aluminum
frame.
FA = Flat aluminum
frame.
L ns Shi lding
Typ :
VA=Virgin acrylic
(standard)
S1=Sky lens 1
S2=Sky lens 2
See options and
consult factory
Lamp
Quantity
2=2 Lamp
3=3 Lamp
FT
Ballast Typ :
<20THD <10THD
1–2 Lamp Elec. TT5 SB * IB *
(40 Watt)
1–3 Lamp Elec. TT5 X3 * I3 *
(40 Watt)
LOL TT5 Dimming PB –
(40 Watt)
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For TT5 UNV, you must use
I
B,
I
3Ballast Code.
Options:
Add appropriate suffix
to catalog no., ie: (A)
Voltag :
120, 277 or
UNV=120-277
Lamp Typ /
Fixtur L ngth:
(Nominal 24")
Twin Tube T5
Not : For Lin ar
T5 Lamp option,
consult factory
SP Standard Specplus Plus
SX For NYC Code – Local 3 Manufactured
C iling Typ :
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and
plaster frame
0.0 45.0 90.0 FLUX
0 3132 3132 3132
5 3115 3117 3135 297
15 2973 3016 3061 852
25 2697 2795 2882 1286
35 2265 2385 2465 1485
45 1677 1773 1880 1367
55 1027 1081 1151 971
65 565 528 585 557
75 285 261 341 316
85 106 113 143 128
90 000
Mod l No. SPS2GFSVA3FT120X3
LER = FP - 58.6 IW - 56.3 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = 4.10
Report Number: G00045
Catalog Number: SPS2GFSVA3FT120X3
Lamps: (3) F40
Luminaire: 2' x 2' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: C340I120
Report is based on 3150 Lumens per lamp.
Efficiency: 76.8%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.875 21.875
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 7620. 8056. 8542.
55 5753. 6055. 6448.
65 4295. 4014. 4448.
75 3538. 3240. 4233.
85 3908. 4166. 5272.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 84 81 78 76 74 72 73 71 70
02 78 72 67 68 64 61 65 62 60
03 71 64 58 61 56 52 58 55 51
04 66 57 51 54 49 45 53 48 45
05 61 52 45 49 44 40 48 43 39
06 56 47 40 45 39 35 44 39 35
07 53 43 36 41 36 32 40 35 31
08 49 39 33 38 32 28 37 32 28
09 46 36 30 35 29 26 34 29 26
10 43 33 28 32 27 24 32 27 23
ZONE LUMENS % LAMP % FIXT
00-030 2435 25.8 33.5
00-040 3920 41.5 54.0
00-060 6258 66.2 86.2
00-090 7260 76.8 100.0
90-180 0000 0.0 000.0
00-180 7260 76.8 100.0
ZONAL LUMEN SUMMARY
Job Information Type:
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595 02/10
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group S ction 1A/Folio E60-22 R v. B
Photom try Sky L ns Options
S1 S2