Lincoln Electric CHD1000 Specification sheet

High-vacuum units
HIGH-VACUUM
UNITS
CHD1000 - 2000 - 3000 - 4000
SAFETY INSTRUCTIONS FOR USE AND MAINTENANCE
N° EM61000120 - EM61000121 - EM61000122 -
EM61000123 - EM61000124
EDITION : EN Instructions for use REF : 8695 8421
REVISION : A
DATE : 12-2021 Original instructions

Thank for the trust you have expressed by purchasing this equipment, which
will give you full satisfaction if you follow its instructions for use and
maintenance.
Its design, component specifications and workmanship comply with
applicable European directives.
Please refer to the enclosed CE declaration to identify the directives
applicable to it.
The manufacturer will not be held responsible where items not recommended
by themselves are associated with this product.
For your safety,there follows a non-restrictive list of recommendations or
requirements, many of which appear in the employment code.
Finally we would ask you kindly to inform your supplier of any error which
you may find in this instruction manual.

8695 8421
CHD I
CONTENTS
A - INTRODUCTION ..........................................................................................................................1
USING THE MANUAL..............................................................................................................1
MACHINE GUARANTEE .........................................................................................................1
ASSISTANCE...........................................................................................................................1
DESCRIPTION OF PICTOGRAMS..........................................................................................1
B - GENERAL SAFETY INSTRUCTIONS.........................................................................................2
ELECTRICAL SAFETY ............................................................................................................2
PERSONAL PROTECTION .....................................................................................................3
FILTRATION OF FUMES AND DUST .....................................................................................5
C - OVERALL DESCRIPTION...........................................................................................................6
DESCRIPTION OF THE EQUIPMENT....................................................................................6
D - TECHNICAL DESCRIPTION .......................................................................................................7
COMPOSITION OF THE UNIT................................................................................................7
DESCRIPTION OF THE UI SCREEN: HOME PAGE..............................................................8
COMPOSITION OF THE ELECTRICAL CABINET..................................................................8
OPERATING PRINCIPLE ........................................................................................................9
FAN OF THE 1000 M³/H - 20000 PA.......................................................................................9
FAN OF THE 1000 M³/H - 25000 PA.......................................................................................10
FAN OF THE 2000 M³/H - 25000 PA.......................................................................................10
FAN OF THE CHD 3000 M³/H - 25000 PA ..............................................................................11
FAN OF THE CHD 4000 M³/H - 25000 PA ..............................................................................11
E - INSTALLING THE UNIT...............................................................................................................12
DIMENSIONS AND LAYOUT...................................................................................................12
CONFIGURATION OF THE UI SCREEN ................................................................................17
F - MAINTENANCE............................................................................................................................22
FAN ..........................................................................................................................................23
MAINTENANCE OF FILTERING ELEMENTS.........................................................................26
ELECTRICAL DIAGRAMS.......................................................................................................27
PERSONAL NOTES ..........................................................................................................................38

8695 8421
II CHD
1) CE DECLARATION OF CONFORMITY/EU
Dear Customer, this EC/EU declaration of conformity guarantees that the equipment supplied complies with
applicable legislation when used in accordance with the enclosed instructions. Any other assembly or
modification would void our certification. That is why you are asked to call in the manufacturer for any
modifications you wish to make. Failing that, the company responsible for the modification must repeat the
certification process. In that case, we would not be liable for the new certificate in any way. Please hand this
document over to your technical department or purchasing department for filing.
Description
Part number
CHD 1000 with 20000 Pa
EM61000120
CHD 1000 with 25000 Pa
EM61000121
CHD 2000 with 25000 Pa
EM61000122
CHD 3000 with 25000 Pa
EM61000123
CHD 4000 with 25000 Pa
EM61000124
NUMBER: See name plate
2) This equipment complies with European directives.
◙ N° 2006/42/CE ◙N° 2011/65/CE ◙N° 2014/30/CE
3) Based on the following harmonised standards:
EN ISO 12100:2010
EN ISO 13850:2008
EN ISO 13857:2008
EN ISO 12499
EN 60204-1:2006 / AC:2010
EN ISO 61439-1 : 2011
EN ISO 61439-2 : 2011
4) Air Treatment Products Manager, authorised to compile the technical manufacturing document
M. Patrick DEGROOTE
LINCOLN ELECTRIC FRANCE SAS
Avenue Franklin Roosevelt
76120 –LE GRAND QUEVILLY
5) Manufacturer
LINCOLN ELECTRIC FRANCE SAS
Avenue Franklin Roosevelt
76120 –LE GRAND QUEVILLY
CERGY, on 07/09/2020
HIGH-VACUUM UNITS
CHD 1000 - 2000 - 3000 - 4000
TYPE : EM61000120 - EM61000121 - EM61000122 -EM61000123 - EM61000124

8695 8421/A
CHD -1
A - INTRODUCTION
USING THE MANUAL
Please read this manual before you start handling, installing or using the machine. Keep the manual safe in a place
known to the user of the machine and maintenance personnel until the machine is finally destroyed.
This manual explains how to transport, install, use and maintain the filter. It cannot in any event replace the experience
of the user for operations of varying difficulty.
Before the filter is used by a new user, make sure that they have read this manual and understood all the explanations
provided.
For any further information, please feel free to contact the technical departments of LINCOLN ELECTRIC.
MACHINE GUARANTEE
This machine is guaranteed for 12 months from the date of purchase.
During the first 12 months of use, defective parts shall be replaced free of charge providing the damage is not the
result of improper use of the machine.
The machine guarantee shall cease automatically when the machine is no longer the property of the original buyer.
The terms of validity of the guarantee shall be subject to verification and acceptance by our sales department.
Any nonconforming use that could damage the machine shall not be covered by the guarantee.
For the guarantee to operate, the equipment must be inspected by our technical department.
ASSISTANCE
LINCOLN ELECTRIC is at your disposal for any work on your equipment.
Please send any requests to the technical department.
HOT LINE (+33) 825 132 132
DESCRIPTION OF PICTOGRAMS
To make this document easier to understand, it contains pictograms with the meanings given below:
DANGER: indication used when failure to follow the instructions could lead to a serious
hazard for personnel.
WARNING: indication used when failure to follow the instructions could lead to damage
to the machine, associated elements or the surroundings.
This symbol shows that the description is intended for specialised personnel.

8695 8421/A
-2 CHD
B - GENERAL SAFETY INSTRUCTIONS
ELECTRICAL SAFETY
Connection to the mains
Before you connect your machine, please make sure that:
—The meter, the overintensity protection system and the electrical installation are compatible with its
maximum power rating and its supply voltage.
—It can be connected, in a single-phase or three-phase with earth system, to a socket compatible with the
plug on its power cord (mobile equipment).
—If the cable is connected to a fixed point, the earth connection, if there is one, may never be cut off by the
system offering protection from electric shocks.
—The switch, if there is one, is set to OFF.
Workstation
Arc welding and cutting requires strict compliance with safety requirements in respect of electrical currents (Order
of 14 December 1988).
Servicing
Before any internal checking or repairs, make sure that the machine has been disconnected from the electrical
installation by locking it out:
—Accidental connection of the cable of a fixed installation has been made impossible
—Cutting off by means of a fixed connection device relates to all poles (phase and neutral. It must be in the
OFF position, with no possibility of being put into service by mistake
Some machines have an HV/HF arc ignition circuit (indicated by a plate). Never work inside such a box.
Any work on electrical installations must be carried out by persons qualified for that purpose (Decree 88-1056 of 14
November 1988, Section VI, Art 46).
Maintenance
From time to time, check that the machinery and its electrical accessories - connectors, flexible cables and
extension cords - are correctly insulated and connected.
Work for maintaining and repairing insulating enclosures and ducts may not be carried out in a haphazard manner
(Section VI, Art. 47 Decree 88-1056 of 14 November 1988).
—All repairs are to be carried out by specialists, or better yet, defective accessories should be replaced.
—Regularly check that the electrical connections are tight, with no heating.
Any fans placed in a circuit in which the air is laden with dust must be cleaned from time to time. That is because
the turbine may be fouled and become unbalanced, leading to increased noise and premature wear and tear of
bearings. Maintenance is required after no more than every six months, depending on the type of dust treated.
The fan is an essential element of your extraction system.
Incorrect operating or inadequate maintenance could make the operating position less safe. That is why the fan
must be maintained in perfect condition.
Your installation has been selected for a specific application. The turbine is characterised by a duty point based on
extraction speed (speed of air in the piping) and head loss.
In accordance with the regulations of CARSAT and INRS, the installation must be inspected from time to time to
make sure that it continues to comply with its reference values.

8695 8421/A
CHD -3
PERSONAL PROTECTION
Risks of external injury relating to welding operations
Whole body
—The operator must be clothed and protected to suit the requirements of the job.
—Make sure that no part of the bodies of operators and helpers can come in contact with metal pieces or
parts that are live or are liable to become live accidentally.
—Do not wind electricity cables around the body.
—Keep safety guards and panels in place.
—The operator must always wear personal insulating protection (Order of 14 December 1988, Section III).
—The protection must be kept dry to prevent electric shocks if it is wet, or ignition in the presence of oil.
Personal protective equipment worn by operators and their helpers - gloves, aprons, safety shoes - offer the added
benefit of protecting them from burns due to hot parts, splatter and slag.
Also make sure the PPE is in good condition and replace it before it ceases to offer protection.
Face and eyes
It is indispensable to protect the following:
—Eyes, from arc injury (dazzling due to visible light from the arc, and infrared and ultraviolet radiation).
—Hair, face and eyes from welding splatter and projection of slag during weld cooling
The welding mask, when used under or without a helmet, must always be equipped with a protective filter, the
shade of which depends on the intensity of the welding arc current (Standards NF S77-104 A 88-221 A88-222).
The coloured filter may be protected from impacts and splatter by a transparent glass located on the front of the
mask.
If the filter is replaced, use another one with the same part number (shade number).
Persons in the vicinity of the operator, especially any helpers, must be protected by means of suitable screens,
anti-UV goggles or, if needed, masks with suitable protective filters (EN 139).

8695 8421/A
-4 CHD
Specific case of chlorine solvents in welding: (used for cleaning or degreasing).
—The fumes from these solvents can be changed into toxic gases when subjected to arc radiation, including
from a distance.
—Such solvents may therefore not be used in locations where electric arcs occur, if the solvents are not in a
sealed enclosure.
Work in confined spaces
Examples:
—Mine roads
—Piping and pipelines
—Ship docks, pits, manholes, cellars
—Tanks
—Ballast tanks
—Silos
—Reactors
Special precautions must be taken before undertaking welding operations in such enclosures, where suffocating
and poisoning and fire and explosion risks are very great.
A work permit procedure setting out all the safety measures must systematically be set up.
Make sure that ventilation is appropriate, paying special attention to:
—under-oxygenation
—over-oxygenation
—excess fuel gas

8695 8421/A
CHD -5
FILTRATION OF FUMES AND DUST
Important
Note that CHD high-vacuum units may be used in combination with a self-cleaning cyclone filter of the 2 or 4 CD
type.
Mechanical or electrostatic filtration systems are effective for the filtration of solid but not gaseous particles (exterior
discharge).
If recycling is effective (not recommended), make sure the workplace where the machine or machines are placed is
properly ventilated, so as to not reach the OELV (occupational exposure limit values) of gaseous pollutants relating
to the specific pollution generated by the method (welding, cutting).
Field of use
Filtration of solid particles and dry dust, non-flammable gas, with no risk of explosion.
—Zinc, paper, flour, plant leaves, graphite, aluminium and other such dust is to be excluded, because
electrostatic discharge or welding splatter would present a risk for those using the filter.
—The air flow through the filter medium must not be at a temperature above 80 °C.
—This machine is not designed for extracting chemicals.
—The choice of machine is made to suit the pollutants to treat. Extraction at source of the pollutant is only
effective if the machine is operating at its nominal power (air flow at the nozzle).
Take particular care to:
—Not obstruct the air outlet of the machine.
—Not introduce external elements into the filter (paper, cloths, cigarette butts etc.)
—Replace the filter medium with new original LINCOLN ELECTRIC medium, which alone can guarantee the
filtration characteristics.
—Replace the hoses if they are pierced.
—Regularly clean the metal pre-filter on those machines that have one

8695 8421/A
-6 CHD
C - OVERALL DESCRIPTION
For your safety and optimum performance, please read this
manual carefully before using the filter.
DESCRIPTION OF THE EQUIPMENT
The sandwich panel on metal structure construction optimises the weight
and strength of the unit. It can be put in place easily thanks to its monobloc
construction, which helps minimise noise. The equipment is managed by a
PLC associated with a 5.7” UI screen. In that way, operating can be
monitored to provide an effective and permanent extraction rate.
The machine quality allows us to offer speedy deliveries, for a low
cost of transport and installation. The system takes up little floor
space and can be disassembled at any time.
Part numbers
Benefits
- Operating cycle managed by a PLC associated with a 5.7” UI screen.
- 3 operating modes possible: Manual –Weekly clock –Automatic.
- Simple installation.
- Compact design.
- Low maintenance that can be scheduled from the user interface (UI) screen.
Delivery :
The unit is delivered in a single bloc including the fan and filtration components.
CHD high-vacuum unit, 1000 m³/h at 20000 Pa
EM61000120
CHD high-vacuum unit, 1000 m³/h at 25000 Pa
EM61000121
CHD high-vacuum unit, 2000 m³/h at 25000 Pa
EM61000122
CHD high-vacuum unit, 3000 m³/h at 25000 Pa
EM61000123
CHD high-vacuum unit, 4000 m³/h at 25000 Pa
EM61000124
Roof CCHD 1000 –2000 –3000 –4000 for outdoor assembly with no roof
EM61000239
Pre-filter box with EU2 (500 x 500 x 24) mm class medium
EM61000127

8695 8421/A
CHD -7
D - TECHNICAL DESCRIPTION
COMPOSITION OF THE UNIT
Components fixed to the unit
Filtration compartment
Dust drum
Fan compartment
Power on indicator
Emergency stop
Main disconnecting
switch

8695 8421/A
-8 CHD
DESCRIPTION OF THE UI SCREEN: HOME PAGE
COMPOSITION OF THE ELECTRICAL CABINET
Next screen
Operating mode:
- Manual
- Weekly clock
- Automatic
Previous
screen
Settings info (Hz –kW)
Fault management
PLC
Circuit
breakers
400/24 V power supply
Relay
Connection
terminal block

8695 8421/A
CHD -9
OPERATING PRINCIPLE
FAN OF THE 1000 M³/H - 20000 PA
Type : Centrifugal fan 15 kW - HPB 590 - 2 - SV87
Operating point: 1000 m³/h with 20000 Pa at 87 Hz
Operating principle of the high-vacuum unit
1
Polluted air is taken into the unit through the pre-
filter located on the panel on the side of the unit.
2
Filtered air is expelled by the fan and discharged
outside. (Upper part).
3
The internal cooling fan allows the removal of the
calories emitted by the main fan.
2
3
1

8695 8421/A
-10 CHD
FAN OF THE 1000 M³/H - 25000 PA
Type : Centrifugal fan 22 kW - HPB 725 - 2 - SV75
Operating point: 1000 m³/h with 24000 Pa at 75 Hz
FAN OF THE 2000 M³/H - 25000 PA
Type : Centrifugal fan 37 kW - HPB 725 - 2 - SV75
Operating point: 2000 m³/h with 24500 Pa at 75 Hz

8695 8421/A
CHD -11
FAN OF THE CHD 3000 M³/H - 25000 PA
Type : Centrifugal fan 45 kW - HPB 725 - 2 - SV75
Operating point: 3000 m³/h with 24000 Pa at 75 Hz
FAN OF THE CHD 4000 M³/H - 25000 PA
Type : Centrifugal fan 55 kW - HPB 725 –2 –SV75
Operating point: 4000 m³/h with 25000 Pa at 79 Hz

8695 8421/A
-12 CHD
E - INSTALLING THE UNIT
MONTAGE
The unit is supplied in a single assembly and only needs to be positioned where it is needed, in the workshop
or outside the building. The filter can be handled with a lift truck thanks to the fork pockets provided under the
frame.
DIMENSIONS AND LAYOUT
- The clearance required for opening the doors is 600 mm.
- A 500 mm technical area must be provided over the perimeter of the unit.
Unit weight CHD 1000 : 700 Kg
Unit weight CHD 2000 : 800 Kg
Unit weight CHD 3000 : 950 Kg
Unit weight CHD 4000 : 1000 Kg
Inlet
Outlet
CHD
Separate version
Ø Inlet –Outlet
(mm)
1000
152 / 200
2000
152 / 250
3000
203 / 315
4000
250 / 315

8695 8421/A
CHD -13
STEP-BY-STEP STARTING OF THE UNIT
In order to guarantee easy and complete starting up, here is the order of the different key stages that must be
carried out:
-Electrical connection of the power supply to the 400 V three-phase system.
-Connection of the remote control with the UI screen.
-UI screen configuration and setup.
Connection to the main
—Three-phase 400V. power supply without
neutral–50 Hz
—Compressed air supply 5 Bars minimum.
Recommendations
1- Electricity supply :
The power supply is to be connected to the terminals of the main disconnector on the side panel of the unit.
Use multi-conductor cable suited to the power of the unit and connect the three phases to the three terminals of the
disconnector and the earth to the earth bar provided.
All the operations relating to the installation,
such as those for assembly, putting into service
and maintenance, are to be carried out by
qualified personnel under the control of a
responsible technician.
Part nos of
electrical
cables
(kW)
MAINS VOLTAGE 50 Hz
230V
single
phase
230 3PH
400 3PH
Section (mm²)
15
4x4
18.5
4x6
22
4x10
37
4x16
45
4x25
55
4x25
Part nos of electrical cables
Cable section
Part no
3x1.5 mm²
W000010098
3x2.5 mm²
W000010099
4x2.5 mm²
W000010100
4x4 mm²
W000010101
4x6 mm²
W000010102
4x10 mm²
W000010103
4x16 mm²
W000010104
4x25 mm²
W000010105
4x35 mm²
W000010106

8695 8421/A
-14 CHD
2- Connecting the stack light :
The stack light has three lights :
-White: power to the filter on
-Green: filter operating
-Red: variable frequency drive fault
3- Putting the unit into service :
Set the main switch (on the side) to 1.
The white power indicator will go on.
The unit is now being supplied with power.
Press the button of the UI screen; the fan starts.
Press the button of the UI screen; the fan starts.
Check the rotation direction of the fan.
Emergency stop
If there is any safety problem or if an electrical fault is found. You can shut down the whole system by pressing on
the emergency stop button. After identifying and solving the problem, reset the emergency stop and follow the
procedure given above for starting up.
Remote control in automatic mode
Two operating modes are possible :
-Remote control using an external contact.
-Remote control with pulse pushbutton (self holding)
Refer to the electrical diagram for the wiring.

8695 8421/A
CHD -15
VARIABLE DRIVE CONFIGURATION
1- Operating principle :
The variable drive is used for one of its most basic functions, namely overspeed operating.
Thanks to the types of fan curve used, we can make a fan operate at a speed from 70 to 87 Hz.
With conventional starting up, it would not be possible to operate it above 50 Hz (electrical system frequency).
Thus, we can operate at overspeed while keeping the system vacuum constant.
2- Settings :
Operating front :
Reference
Description
Comments
0
% indicator
Goes on when a numerical value is
displayed as a percentage.
Hz indicator
Goes on when a numerical value is
displayed in Hertz.
1
RUN indicator
Goes on when an activation control is
triggered.
PRG indicator
Goes on when the variable drive is in
setup mode and flashes when it is in
AUF mode.
MON indicator
Goes on when the variable drive is in
monitoring mode.
2
MODE key
Displays the operating frequency,
settings and reasons for errors.
3
ENT enter key
4
STOP stop key
Each press on the key when the Run
indicator is on slows the device down
till it stops completely.
5
RUN key
If you press this key when the Run
indicator is on, the variable drive
starts.
RUN indicator
Goes on when you press the RUN key.
6
LOC REM local/remote key
Switches between the 2 modes.
LOC REM key indicator
Goes on when the Local mode is
activated
7
Down key
Up key
Indicators of keys
You can modify the frequency if it is on
Reference
Description
Comments
1
Front panel
Guard panel
2
Charge indicator
Indicates that voltage is still present in
the variable drive
3
Locked position indicator
Panel locked in this position
4
Panel locking screw
Screw for locking the panel
5
Unlocked position indicator
Panel unlocked in this position

8695 8421/A
-16 CHD
Configuration based on the settings :
Location of settings :
Versions
1000m³/h
20000 Pa
1000m³/h
25000 Pa
2000m³/h
25000 Pa
3000m³/h
25000 Pa
4000m³/h
25000 Pa
Parameter
Description
Value
Value
Value
Value
Value
FMOD
Input data by integrate
terminal
1
1
1
1
1
CMOD
On/Off control by the
terminal block
0
0
0
0
0
FH
Max. frequency (Hz)
87
75
75
75
79
LL
Min. regulation
frequency (Hz)
87
71
71
71
75
UL
Max. regulation
frequency (Hz)
87
71
71
71
75
ACC
Acceleration time
90
90
90
90
90
DEC
Deceleration time
200
200
200
200
200
uL
Mains frequency
50
50
50
50
50
uLu
Mains voltage
400
400
400
400
400
Thr
Thermal protection
Depending
on power
Depending
on power
Depending
on power
Depending
on power
Depending
on power
AUF
AU1
ACC
DEC
LL=75
UL=75
uL=50
uLu=400
FH= 75
NB1: Before starting to set the variable drive, make sure that this
screen
Indicates the following value, 0.00, which is its initial condition.
NB 2: To enter the setting, press Enter.
To confirm the new value, press Enter once again.
This manual suits for next models
3
Table of contents