Lisun Group LSP-500VA User manual

User’s Manual
AC Power Source
(LSP-500VA/LSP-1KVA/LSP-2KVA)
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,
Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Lead in CFL & LED Test Instruments

Lisun Electronics Inc.
-Page 1 -
CONTENTS TABLE
Chapter 1 Precautions………………………………………………………………… 2
Chapter 2 Concept for Variable Frequency Power Supply
System……………………………………………………………………….. 2
Chapter 3 Block Diagram for Operation of LSP Series of Variable
Frequency Power Supply……………………………………………. 3
Chapter 4 Method for Selecting Power Capacity………………………… 3
Chapter 5 Instruction for Control Panel of Variable Frequency
Power Supply……………………………………………………………… 4
Chapter 6 Installation Instruction & Operating Instruction……….. 5
Chapter 7 Specifications for Electrical Equipment……………………… 6
Chapter 8 Exception Handling……………………………………………………. 7
Chapter 9 Precautions for Use……………………………………………………. 7

Lisun Electronics Inc.
-Page 2 -
Chapter 1 Precautions
Thanks for purchasing the product of our company. Please carefully read this
manual before use and safely keep it.
1. Please carefully and slightly move the machine to avoid collision.
2. Please proceed according to the installation instruction.
3. Please operate according to the steps indicated in the operating instruction.
4. Never open the cover to avoid electric shock and damages.
5. Keep the machine clean.
6. Please protect the machine from humidity, stuffiness and direct sunlight.
7. Refer to the procedure “Solutions for Abnormal” in case of abnormal conditions.
Chapter 2 Concept for Variable Frequency Power
Supply System
Inverter power supply through AC – DC – AC conversion is called variable frequency
power supply, which differs from variable frequency speed controller and common
AC stabilized voltage power supply. Variable frequency power supply is mainly used
for convert existing AC power network supply into stable and pure Sine power
supply of required frequency. The features of ideal AC power supply are stable
frequency, stable voltage, zero internal resistance and Sine wave form (without
distortion). Variable frequency power supply is close to the ideal AC power supply,
so the developed countries more frequently use variable frequency power supply as
the standard supply, so as to provide the most excellent powering environment for
electrical equipments and easily evaluate their technical performance. There are
two types of variable frequency power supply: Linear Amplification and PWM Switch.
Variable frequency power supply, taking the microprocessor as its core, is
manufactured by MPWM. It is designed using active component IGBT module, and
adopts such technologies as digital frequency division, D/A conversion,
instantaneous feedback and sinusoidal pulse width modulation to make the capacity
of single machine up to 100KVA. The stability of entire machine is added by
separating transformer output. It is featured with strong load applicability, high
quality output waveform, and simple operation, small and light. In addition, this
power supply has many protective functions against short circuit, over current, over
load and over heat to ensure it’s properly operation.

Lisun Electronics Inc.
-Page 3 -
Chapter 3 Block Diagram for Operation of LSP
Series of Variable Frequency Power Supply
Chapter 4 Method for Selecting Power Capacity
1. Resistance: Power Capacity = 1.1× Load Power
LoadStartingCurrent
2. Induction: Power Capacity = ────────── × Load Power
LoadRatedCurrent
WaveCrestCoefficientfor LoadCurrent
3. Rectification: Power Capacity = ────────── × Load Power
1.5
4. Mixed: Please properly select according to the percentage of different loads.
Note: For such inductive loads as refrigerator and air conditioning, the power
capacity should be selected according to the starting power.

Lisun Electronics Inc.
-Page 4 -
Chapter 5 Instruction for Control Panel of
Variable Frequency Power Supply
All items on the panel will be described in the order from left to right and from top
to bottom.
1. Output Frequency Display: Digitally display output frequency accurate to the
digit after radix point.
2. Output Voltage Display: Digitally display output voltage.
3. Output Current Display: Digitally display output current.
4. Output Power and Power Factor Display: Digitally display output power and
power factor values.
5. Output Power LED.
6. Power Factor LED.
7. Power and Power Factor Conversion Button. Power and power factor conversion
is possible by this button.
8. Voltage Spin Button for Nominal Value Above: This button allows you to slightly
adjust the voltage between 10% and 25% more than the nominal voltage.
9. Voltage Spin Button for Nominal Value Below: This button allows you to slightly
adjust the voltage between 10% and 30% less than the nominal voltage.
10. Tri-Position Voltage Selector: High: Voltage More Than Nominal Value.
Middle: Nominal Voltage.
Low: Voltage Less Than Nominal Value.
11. Nominal Voltage Output Spin Button: Cross-Type spin switch with locking
feature, it allows you to get the required nominal voltage by slightly
adjustment.
12. Switch: Fixed Frequency 50Hz, 60Hz, Adjustable Frequency, 400Hz Switching
Selector.
13. Frequency Spin Button: Adjustable between 45 Hz and 70 Hz.
14. Start/Stop Button: Output LED (15) will light at starting, and variable frequency
power supply outputs voltage. Output LED (15) will be off at stopping, and
variable frequency power supply doesn’t output voltage.
15. Output LED: It will light when variable frequency power supply outputs voltage.
16 Reset Button: When variable frequency power supply trips and the alarm sounds
due to some failures, one of four protective LEDs will light, then you can press this
button to reboot the power.
17.IGBT – Power Module IGBT Protective LED.
18. O.CT – (OVER CURRENT) Over Current Protective LED.
19. O.HT – (OVER HEAT) Over Heat Protective LED.
20. O.LD – (OVER LOAD) Over Load Protective LED.

Lisun Electronics Inc.
-Page 5 -
Chapter 6 Installation Instruction & Operating
Instruction
6.1 Installation Instruction
1. Determine the input voltage before using the power source.
2. Turn the voltage knob to the minimum voltage, i.e. rotate it counterclockwise to
the minimum position.
3. Before connection to the power source, turn all switches to OFF to make sure
the device has no possible damage.
4. The power source can only be connected when the device specification exactly
match that of the power source system.
6.2 Operating Instruction
1. Check whether control switches, knobs and displays are fine before using them.
2. Turn the power switch to the OFF position firstly.
3. Please determine again whether the input voltage is correct before connection
to the power supply, to make sure the equipment is safe.
4. Internal AC contactor of the power supply picks up about 3 to 5 seconds after
powering on. Press the Start button, and the output LED will light, indicating
there is output voltage from power supply. Press again the Start button, and the
output LED will be off, indicating there is no output voltage from the power
supply.
5. Output Frequency Adjustment: you can turn the frequency selector to any
position without powering on/off. The frequency indicated at fixed position is
output frequency. To slightly adjust frequency, it is necessary to turn the fixed
position to the rightmost and then adjust the spin button.
6. For example: To get the frequency of 52Hz, please firstly turn the selector to the
VAR position, and then adjust the spin button until 52Hz appears on the display.
7. Nominal Voltage Adjustment: Turn the tri-position voltage selector to the Middle
position, and then rotate the cross-type spin button on the right to get the
desired voltage.
8. Connect the load to the terminal block, and press the Start button, and the
output LED will light. In this way, you can easily get all values displayed on the
functional display.
9. Notice (I): Over current, over load, over heat and short circuit protective
devices are supplied with this machine. In case of over current, over load, over
heat or short circuit, the protective circuit will immediately cut off the power and
the buzzer will sound alarm. At this time, please firstly turn the load off, and
then press the button Reset. The power supply begins providing the power after
the alarm stops. Check the load conditions, and then turn the load on after
determining there is no exception.
10. Notice (II): Warning! If it is necessary to make 220V/110V conversion (inside

Lisun Electronics Inc.
-Page 6 -
door panel), please do it after turning the load off to make sure the equipment
is safe.
11. Notice (III): Warning! If it is necessary to get the frequency of 400Hz or release
the frequency of 400Hz, please make conversion after turning the load off.
Chapter 7 Specifications for Electrical Equipment
Model LSP-500VA/1KVA/2KVA
OutputCapacity 500 VA/1 KVA/2KVA
CircuitType (IGBT) MPWM Pulse Duration Modulation
InputVoltage 220V
InputFrequency 50Hz/60Hz
OutputVoltage HIGH/LOW Adjustable Phase Voltage
Range:(HIGH)0~300V, (LOW)0~150V。
Output Frequency Adjustable between 45.0—70.0
Hz;50Hz,60Hz,100Hz, 200Hz, 400Hz
Load Voltage Stabilization Rate ≦0.5%
Frequency Stabilization Rate
0.10%
WaveDistortionRate ≦2% (Resistor Load)
Efficiency ≧85%
OutputInstruments Frequency Indicator, 4-digits RMS digital
frequency indicator, resolution 0.1Hz
Voltage Meter, 4-digits RMS digital
voltage meter, resolution 0.1V
Ampere Meter, 4-digist RMS digital
ampere meter, resolution 1mA
Power Indicator, 4-digits RMS digital
power indicator, resolution 1W
Power Factor Meter Resolution 0.001
ProtectiveDevices: Over load, short circuit, over voltage,
over current, over temperature
protective and alarm devices.
Operating Environment Temperature 0~40℃Relative Humidity
0~90%

Lisun Electronics Inc.
-Page 7 -
Chapter 8 Exception Handling
EXCEPTIONS SOLUTIONS
Startup impossible 1. Lose power or not.
2. Turn “OFF” to “ON”.
3. Check power cord, plug and socket.
Output frequency is
normal, but the voltage
meter and ampere meter
display “0”
1. Turn the power switch to “OFF”.
2. Turn the output voltage-regulating switch to zero.
3. Turn the power switch to “ON”.
Output frequency is
normal, but the voltage
meter and ampere meter
display “0” and alarm tone
sounds
1. Reduce the load current.
2. Activate the switch “RESET”
3. Wait for the machines delayed startup.
4. Repeat previous operations.
Other exceptions excluding
above problems Please contact the service department of our
company.
Chapter 9 Precautions for Use
The instruments should operate in the specified environments. The installation
environments need to be noticed considering the function and service life of the
instruments:
Protect from rain, humidity, high temperature, over heat or direct sunlight.
The distance between the ventilation hole and surrounding objects should be not
less than 40cm.
Protect from operating in the places with corrosive liquids, gases, dusts,
conductive fibers or mass metal particles.
Protect from operating in the places with vibration or electromagnetic
interference.
Avoid long-term storage and transportation bottom up, and intensive shock is
prohibited.
Precautions during Instrument Use:
Too high or low input voltage (198V-242V) is not allowable. Otherwise the power
module will not work properly, and the protective LED of the power module will
light and the alarm will sound.

Lisun Electronics Inc.
-Page 8 -
Never power off at the instrument running.
Never contact the charged positions to avoid electric shock at the instrument
running.
The personnel without professional training are not allowed to open the
enclosure.
This manual suits for next models
2
Table of contents