ON OFF ON OFF ON OFF
[I] [I] [II] [II] [I]+[II] [I]+[II]
INSTALLATION:
Receiver LMR-400 (Refer to Fig. 1)
zDisconnect main power before installation.
zConnect AC wire (Live & Neutral) to receiver block terminal IN.
zConnect Load wires into receiver block terminal OUT (Port I & Port II) .
zConnect main power on.
OPERATION :
1. Transmitter LMT-1009
(Refer to Fig. 2)
zMain [I] “ON” button: Turns on main [I] light
zMain [I] “OFF” button: Turns off main [I] light
(Refer to Fig. 3)
zSecondary [II] “ON” button: Turns on main [II] light
zSecondary [II] “OFF” button: Turns off main [II] light
z“DELAY OFF” button: Turns off automatically after 10 seconds.
z“Security mode”: Randomly turns on & off the lights.
To activate, hold both “ON and OFF” button of Main [I] for 3 seconds.
To deactivate, simply press any button on the transmitter.
※REMARK※
In order to operate with a transmitter, the mechanical switch must be powered “ON”
2. Mechanical Switch (Refer to Fig. 4)
z1st time “ON” will control the main [I] light
z2nd time “ON” will control the secondary [II] light
z3rd time “ON” will control both main [I] and secondary [II] light.
HOW TO LINK CODE:
zTo start, program transmitter with receiver.
zConnect power to receiver
zSwitch ON first then OFF and ON cycle for 6 times, this will enter learning mode.
While in learning mode, the main [I] light connected to receiver will flash to indicate ready for programming.
zThen on transmitter press the main [I] “ON” button once, main [I] and secondary [II] light will flash 2 times to indicate
programming is confirmed and completed.
!
During leaning mode if within 12 seconds no signal is detected it will automatically return to stand-by
mode.
Fig. 2 Fig. 3 Fig. 4