Assembly instructions | LK Electric Portable Boiler
Circulation Pump
For setting up the circulation pump, see separa-
te instruction ”Grundfos UPM3 Auto L 15/70”.
Note that the pump is advantageously set to work
with constant pressure and that this must be set
manually according to separate instructions.
QR code for assembly instruction UPM3
Trip switch, circulation pump
The circulation pump is protected by a 10 A Trip
Switch (13). In the event of the fuse tripping out,
determine the cause of the fault and x it before
restarting.
Safety valve
The safety valve must be tested at start-up and
then at set intervals 2-3 times per year. CAU-
TION: Take care when testing as the out-owing
water/steam can cause scald injuries.
Pump graph
Installation
The boiler should be placed indoors/under a roof
and fully protected from rain.
The integrated safety package including automa-
tic air-bleed valve, safety valve and connecting
hoses, must be installed as shown in the product
diagram (see above). Relevant building stan-
dards and hot water installation standards must
be adhered to.
The safety valve’s outlet’s functioning must be
ensured in the appropriate manner; refer to cur-
rent hot water installation standards. No thermo-
meter is included in the standard kit. However,
a thermometer should be mounted on the pipe
after the boiler.
The heating system must be arranged so that there
is always a ow through the electrical cartridge.
Check to see that one or more of the heating loops
are always open.
Switching on
Before switching on, check to see that the heating
system is lled with water, air-bled and that the
system’s operating pressure is sufcient.
Check to see that the circulation pump is run-
ning by listening to and testing the various pump
speed settings.
Thermostat operation
Temperature regulation is via the boiler’s opera-
tional thermostat (constant output temperature).
The thermostat can be set up to a maximum of 60
ºC. Monitor the output temperature by means of
a thermometer and compare it to the set tempe-
rature.
Overheating protection
Theboilerisprovidedwithbuiltinoverheatingpro-
tection, which cuts off the power at approx. 80 ºC.
To reset the overheating protection function,
press button (12). Resetting is possible after the
boiler has cooled down to approx. 65 ºC. In the
event of a repeated overheating, determine the
cause of the fault and x it before restarting.