DB15-000260-03
MegaRAID®320
Storage Adapters
USER’S
GUIDE
July 2003

ii Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Electromagnetic Compatibility Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product.
LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this
equipment or the substitution or attachment of connecting cables and equipment other than those specified by
LSI Logic. The correction of interferences caused by such unauthorized modification, substitution, or attachment will
be the responsibility of the user.
The LSI Logic MegaRAID 320 storage adapters are tested to comply with FCC standards for home or office use.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information
Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may
cause radio interference. Install and use the equipment according to the instruction manual.
LSI Logic Corporation
North American Headquarters
Milpitas, CA
408.433.8000

iii
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
This document contains proprietary information of LSI Logic Corporation. The
information contained herein is not to be used by or disclosed to third parties
without the express written permission of an officer of LSI Logic Corporation.
LSI Logic products are not intended for use in life-support appliances, devices,
or systems. Use of any LSI Logic product in such applications without written
consent of the appropriate LSI Logic officer is prohibited.
Document DB15-000260-03, July 2003.
This document describes the current version of LSI Logic Corporation’s
MegaRAID 320 Storage Adapters and will remain the official reference source for
all revisions/releases of these products until rescinded by an update.
LSI Logic Corporation reserves the right to make changes to any products herein
at any time without notice. LSI Logic does not assume any responsibility or
liability arising out of the application or use of any product described herein,
except as expressly agreed to in writing by LSI Logic; nor does the purchase or
use of a product from LSI Logic convey a license under any patent rights,
copyrights, trademark rights, or any other of the intellectual property rights of
LSI Logic or third parties.
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
TRADEMARK ACKNOWLEDGMENT
LSI Logic, the LSI Logic logo design, Fusion-MPT, and MegaRAID are
trademarks or registered trademarks of LSI Logic Corporation. Microsoft,
Windows, and Windows NT are registered trademarks of Microsoft Corporation.
Novell NetWare is a registered trademark of Novell Corporation. UNIX and
UnixWare are registered trademarks of The Open Group. SCO is a registered
trademark of Caldera International, Inc. Linux is a registered trademark of Linus
Torvalds. Red Hat isa registered trademark of Red Hat, Inc. SuSE is a registered
trademark of SuSE Linux AG. All other brand and product names may be
trademarks of their respective companies.
DR
To receive product literature, visit us at http://www.lsilogic.com.
For a current list of our distributors, sales offices, and design resource
centers, view our web page located at
http://www.lsilogic.com/contacts/index.html

iv Copyright © 2003 by LSI Logic Corporation. All rights reserved.

MegaRAID 320 Storage Adapters User’s Guide v
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Preface
This book is the primary reference and user’s guide for the LSI Logic
MegaRAID®320 Storage Adapters. It contains complete installation
instructions for these adapters and includes specifications for them.
The LSI Logic MegaRAID 320 Storage Adapter family consists of the
following:
•MegaRAID 320-1 PCI SCSI Disk Array Controller
Model Number: Series 520
•MegaRAID 320-2 PCI SCSI Disk Array Controller
Model Number: Series 518
•MegaRAID 320-2X PCI SCSI Disk Array Controller
Model Number: Series 532
•MegaRAID 320-4X PCI SCSI Disk Array Controller
Model Number: Series 531
To obtain an overview of RAID, see the LSI Logic RAID Primer (available
for download from the LSI Logic web site).
For information about how to configure the storage adapters, and for an
overview of the software drivers, see the MegaRAID Software User’s
Guide.
Audience
This document assumes that you have some familiarity with RAID
controllers and related support devices. The people who benefit from this
book are
•engineers who are designing a MegaRAID 320 storage adapter into
a system
•anyone installing a MegaRAID 320 storage adapter in their RAID
system

vi Preface
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Organization
This document has the following chapters and appendixes:
•Chapter 1, Overview, provides a general overview of the LSI Logic
MegaRAID 320 series of PCI-to-SCSI storage adapters with RAID
control capabilities.
•Chapter 2, MegaRAID 320-1, -2, -2X, -4X Hardware Installation,
describes the procedures for installing the MegaRAID 320-1, -2, -2X,
and -4X storage adapters.
•Chapter 3, MegaRAID 320 Storage Adapter Characteristics,
provides the characteristics and technical specifications for the
MegaRAID 320-1, -2, -2X, and -4X storage adapters.
•Chapter 4, Installing and Configuring Clusters, explains how to
implement clustering to enable two independent servers to access
the same shared data storage.
•Appendix A, Glossary of Terms and Abbreviations, lists and
explains the terms and abbreviations used in this manual.
Related Publications
LSI Logic RAID Primer, LSI Logic Document No. DB09-000123-00
(available for download from the LSI Logic web site)
MegaRAID Software User’s Guide, LSI Logic Document No. DB15-
000269-00 (on the CD included with the MegaRAID 320 storage adapter)
MegaRAID Device Driver Installation User’s Guide, LSI Logic Document
No. DB11-000018-00 (on the CD included with the MegaRAID 320
storage adapter)
Safety Instructions
Use the following safety guidelines to help protect your computer system
from potential damage and to ensure your own personal safety.
When Using Your Computer System
As you use your computer system, observe the following safety
guidelines:

Preface vii
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
CAUTION: Do not operate your computer system with any cover(s)
(such as computer covers, bezels, filler brackets, and front-
panel inserts) removed:
•To help avoid damaging your computer, be sure the voltage selection
switch on the power supply is set to match the alternating current
(AC) power available at your location:
– 115 volts (V)/60 hertz (Hz) in most of North and South America
and some Far Eastern countries such as Japan, South Korea,
and Taiwan
– 230 V/50 Hz in most of Europe, the Middle East, and the Far
East. Also be sure your monitor and attached peripherals are
electrically rated to operate with the AC power available in your
location.
•To help avoid possible damage to the system board, wait five
seconds after turning off the system before removing a component
from the system board or disconnecting a peripheral device from the
computer.
•To help prevent electric shock, plug the computer and peripheral
power cables into properly grounded power sources. These cables
are equipped with 3-prong plugs to ensure proper grounding. Do not
use adapter plugs or remove the grounding prong from a cable. If
you must use an extension cable, use a 3-wire cable with properly
grounded plugs.
•To help protect your computer system from sudden, transient
increases and decreases in electrical power, use a surge suppressor,
line conditioner, or uninterruptible power supply.
•Be sure nothing rests on your computer system’s cables and that the
cables are not located where they can be stepped on or tripped over.
•Do not spill food or liquids on your computer. If the computer gets
wet, consult the documenation that came with it.
•Do not push any objects into the openings of your computer. Doing
so can cause fire or electric shock by shorting out interior
components.
•Keep your computer away from radiators and heat sources. Also, do
not block cooling vents. Avoid placing loose papers underneath your
computer; do not place your computer in a closed-in wall unit or on
a rug.

viii Preface
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
When Working Inside Your Computer
Notice: Do not attempt to service the computer system yourself,
except as explained in this guide and elsewhere in LSI
Logic documentation. Always follow installation and service
instructions closely.
1. Turn off your computer and any peripherals.
2. Disconnect your computer and peripherals from their power sources.
Also disconnect any telephone or telecommunications lines from the
computer.
Doing so reduces the potential for personal injury or shock.
Also note these safety guidelines:
•When you disconnect a cable, pull on its connector or on its strain-
relief loop, not on the cable itself. Some cables have a connector with
locking tabs; if you are disconnecting this type of cable, press in on
the locking tabs before disconnect the cable. As you pull connectors
apart, keep them evenly aligned to avoid bending any connector
pins. Also, before you connect a cable, make sure both connectors
are correctly oriented and aligned.
•Handle components and cards with care. Don’t touch the
components or contacts on a card. Hold a card by its edges or by its
metal mounting bracket. Hold a component such as a
microprocessor chip by its edges, not by its pins.
Protecting Against Electrostatic Discharge
Static electricity can harm delicate components inside your computer. To
prevent static damage, discharge static electricity from your body before
you touch any of your computer’s electronic components, such as the
microprocessor. You can do so by touching an unpainted metal surface,
such as the metal around the card-slot openings at the back of the
computer.
As you continue to work inside the computer, periodically touch an
unpainted metal surface to remove any static charge your body may have
accumulated. In addition to the preceding precautions, you can also take
the following steps to prevent damage from electrostatic discharge
(ESD):

Preface ix
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
•When unpacking a static-sensitive component from its shipping
carton, do not remove the component from the antistatic packing
material until you are ready to install the component in your
computer. Just before unwrapping the antistatic packaging, be sure
to discharge static electricity from your body.
•When transporting a sensitive component, first place it in an
antistatic container or packaging.
•Handle all sensitive components in a static-safe area. If possible, use
antistatic floor pads and workbench pads.

x Preface
Copyright © 2003 by LSI Logic Corporation. All rights reserved.

MegaRAID 320 Storage Adapters User’s Guide xi
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Contents
Chapter 1
Overview 1.1 Overview 1-1
1.2 Features 1-3
1.3 Hardware 1-4
1.3.1 Storage Adapter Configurations 1-4
1.3.2 Configuration on Disk 1-6
1.3.3 Drive Roaming 1-6
Chapter 2
MegaRAID 320-1, -2, -2X, -4X Hardware Installation
2.1 Requirements 2-1
2.2 Quick Installation 2-2
2.3 Detailed Installation 2-2
2.4 After You Have Installed the Storage Adapter 2-8
Chapter 3
MegaRAID 320 Storage Adapter Characteristics
3.1 The MegaRAID 320 Storage Adapter Family 3-1
3.1.1 Single-Channel Storage Adapter 3-2
3.1.2 Dual-Channel Storage Adapters 3-4
3.1.3 Quad-Channel Storage Adapter 3-7
3.2 MegaRAID 320 Storage Adapter Characteristics 3-10
3.3 Technical Specifications 3-10
3.3.1 Storage Adapter Specifications 3-10
3.3.2 Array Performance Features 3-13
3.3.3 Fault Tolerance 3-13
3.3.4 Electrical Characteristics 3-14
3.3.5 Thermal and Atmospheric Characteristics 3-14

xii Contents
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
3.3.6 Safety Characteristics 3-15
Chapter 4
Installing and Configuring Clusters
4.1 Overview 4-1
4.2 Benefits of Clusters 4-2
4.3 Installation and Configuration 4-2
4.3.1 Driver Installation Instructions under Microsoft
Windows 2000 Advanced Server 4-3
4.3.2 Network Requirements 4-4
4.3.3 Shared Disk Requirements 4-5
4.4 Cluster Installation 4-5
4.4.1 Installing Microsoft Windows 2000 4-7
4.4.2 Setting Up Networks 4-7
4.4.3 Configuring the Cluster Node Network Adapter 4-8
4.4.4 Setting Up the First Node in Your Cluster 4-9
4.4.5 Configuring the Public Network Adapter 4-10
4.4.6 Verifying Connectivity and Name Resolution 4-11
4.4.7 Verifying Domain Membership 4-12
4.4.8 Setting Up a Cluster User Account 4-12
4.4.9 Setting Up Shared Disks 4-13
4.4.10 Configuring Shared Disks 4-14
4.4.11 Assigning Drive Letters 4-15
4.4.12 Verifying Disk Access and Functionality 4-15
4.4.13 Installing Cluster Service Software 4-16
4.4.14 Configuring Cluster Disks 4-18
4.4.15 Validating the Cluster Installation 4-25
4.4.16 Configuring the Second Node 4-26
4.4.17 Verifying Installation 4-26
4.5 Installing SCSI Drives 4-27
4.5.1 Configuring the SCSI Devices 4-28
4.5.2 Terminating the Shared SCSI Bus 4-28
Appendix A
Glossary of Terms and Abbreviations
Customer Feedback

xiv Copyright © 2003 by LSI Logic Corporation. All rights reserved.

xv
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Tables 1.1 MegaRAID 320 Storage Adapter Comparisons 1-4
2.1 Target ID’s 2-4
3.1 MegaRAID 320-1 Headers and Connectors 3-2
3.2 MegaRAID 320-2 Headers and Connectors 3-4
3.3 MegaRAID 320-2X Headers and Connectors 3-6
3.4 MegaRAID 320-4X Headers and Connectors 3-8
3.5 Storage Adapter Characteristics 3-10
3.6 Storage Adapter Specifications 3-11
3.7 Array Performance Features 3-13
3.8 MegaRAID 320 Fault Tolerance Features 3-13
3.9 Maximum Power Requirements 3-14
4.1 Nodes and Storage Devices 4-6

xvi Copyright © 2003 by LSI Logic Corporation. All rights reserved.

MegaRAID 320 Storage Adapters User’s Guide 1-1
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
Chapter 1
Overview
This section provides a general overview of the LSI Logic MegaRAID 320
series of PCI-to-SCSI storage adapters with RAID control capabilities. It
consists of the following sections.
•Section 1.1, “Overview,” page 1-1
•Section 1.2, “Features,” page 1-3
•Section 1.3, “Hardware,” page 1-4
1.1 Overview
The LSI Logic MegaRAID 320 storage adapters are high-performance
intelligent Peripheral Component Interconnect to Small Computer
System Interface (PCI-to-SCSI) host adapters with Redundant Array of
Independent Disks (RAID) control capabilities. MegaRAID 320 storage
adapters provide reliability, high performance, and fault-tolerant disk
subsystem management. They are an ideal RAID solution for the internal
storage of workgroup, departmental, and enterprise systems.
MegaRAID 320 storage adapters offer a cost-effective way to implement
RAID in a server.
MegaRAID 320 storage adapters are available with one, two, or four
SCSI channels.
•The MegaRAID 320-1 storage adapter (single-channel) has one
LSI53C1020 controller chip that controls one SCSI channel. The
storage adapter has one very high-density cable interconnect
(VHDCI) 68-pin external SCSI connector and one high-density cable
interconnect (HDCI) 68-pin internal SCSI connector.
•The MegaRAID 320-2 storage adapter (dual-channel) has one
LSI53C1030 controller chip that controls two SCSI channels. The

1-2 Overview
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
storage adapter has two VHDCI 68-pin external SCSI connectors
and two HDCI 68-pin internal SCSI connectors.
•The MegaRAID 320-2X storage adapter (dual-channel) has one
LSI53C1030 controller chip that controls two SCSI channels. The
storage adapter has two VHDCI 68-pin external SCSI connectors
and two HDCI 68-pin internal SCSI connectors. Note that the
MegaRAID 320-2X is a PCI-X controller.
•The MegaRAID 320-4X storage adapter (quad-channel) has two
LSI53C1030 controller chips that control the four SCSI channels. The
storage adapter has four VHDCI 68-pin external SCSI connectors
and two HDCI 68-pin internal SCSI connectors. Note that the
MegaRAID 320-4X is a PCI-X controller.
The MegaRAID 320 storage adapters support a low voltage differential
(LVD) or a single-ended (SE) SCSI bus. With LVD, you can use cables
up to 12 meters long. Throughput on each SCSI channel can be as high
as 320 Mbytes/s.
You can install the MegaRAID 320 storage adapters in PCI-X computer
systems with a standard bracket type. With these adapters in your PCI
or PCI-X system, you can connect SCSI devices over a SCSI bus.
For Ultra320 SCSI performance, you must connect only LVD devices to
the bus. Do not mix SE with LVD devices, or the bus speed will be limited
to the slower SE (Ultra SCSI) SCSI data transfer rates. Do not connect
a high voltage differential (HVD) device to the SCSI bus because the chip
on the storage adapter must be reset to return to LVD or SE mode once
the HVD device is removed.
The MegaRAID 320 storage adapters support major operating systems,
such as Windows (NT 4.0, 2000, Server 2003, and XP), Red Hat Linux,
SuSe Linux, Novell NetWare, SCO OpenServer, and UnixWare. Other
software support ensures data integrity by intelligently testing the
network before completing negotiation.
Note: The MegaRAID 320-1 and 320-2 adapters support
Windows NT 4.0, but MegaRAID 320-2X and 320-4X do
not. Refer to the MegaRAID Device Driver Installation
User’s Guide for driver installation instructions.
The MegaRAID 320 storage adapters use Fusion-MPT™ architecture for
all major operating systems for thinner drivers and better performance.

Features 1-3
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
To obtain a driver for an operating system other than the ones listed
above, contact the LSI Logic technical support team at 1-678-728-1250,
or visit our website at http://www.lsilogic.com.
1.2 Features
Features of the LSI Logic MegaRAID 320 storage adapters include:
•Support for hard disk drives with capacities greater than 8 Gbytes
•Online RAID level migration
•RAID remapping
•No reboot necessary after expansion (for NT 4.0: if virtual sizing is
enabled)
•More than 200 Qtags per array
•Hardware clustering support on the board
•User-specified rebuild rate
•Wide Ultra320 LVD SCSI performance up to 320 Mbytes/s
•MegaRAID 320-1 has 64 Mbytes of synchronous dynamic random
access memory (SDRAM)
•MegaRAID 320-2 supports up to 256 Mbytes of SDRAM; a 32-,
64-, 128-, or 256-Mbyte DIMM can be installed.
•MegaRAID 320-2X and -4X support up to 1 Gbyte of double data
rate (DDR) SDRAM; a 32-, 64-, 128-, 256, or 512-Mbyte, or 1-Gbyte
DIMM can be installed.
•MegaRAID 320-2, -2X, and -4X support a 64-bit PCI host interface
(note that the -2X and -4X are PCI-X controllers)
•MegaRAID 320-1 has one internal and one external SCSI connector;
MegaRAID 320-2 and -2X have two internal and two external SCSI
connectors; MegaRAID 320-4X has two internal and four external
SCSI connectors.
•Support for RAID levels 0 (striping), 1 (mirroring), 5 (striping and
parity data across all drives), 10 (mirroring and striping), and 50
(RAID 5 and striping)
•Advanced array configuration and management utilities

1-4 Overview
Copyright © 2003 by LSI Logic Corporation. All rights reserved.
•Battery backup for up to 72 hours for the MegaRAID 320-2, -2X, and
-4X
•Support for up to 14 SCSI drives per channel on storage system with
SAF-TE enclosures (SCSI accessed fault-tolerant enclosures):
15 SCSI drives per channel for other configurations
•32 Kbyte x 8 NVRAM for storing RAID system configuration
information; the MegaRAID 320 firmware is stored in flash ROM for
easy upgrade.
Note: The MegaRAID 320-1 does not support clustering.
1.3 Hardware
You can install the MegaRAID 320-1 and -2 in a computer with a
motherboard that has 5 V or 3.3 V, 32- or 64-bit PCI slots. You can install
the MegaRAID 320-2X and -4X in a computer with a motherboard that
has 3.3 V, 64-bit PCI-X slots.
The following subsections describe the hardware configuration and
configuration-on-disk for the MegaRAID 320 storage adapters.
1.3.1 Storage Adapter Configurations
Table 1.1 compares the configurations for the MegaRAID 320-1, -2, -2X,
and -4X storage adapters.
Table 1.1 MegaRAID 320 Storage Adapter Comparisons
MegaRAID 320-1 MegaRAID 320-2 MegaRAID 320-2X MegaRAID 320-4X
RAID Levels 0, 1, 5, 10, 50 0, 1, 5, 10, 50 0, 1, 5, 10, 50 0, 1, 5, 10, 50
SCSI Device Types Synchronous or
Asynchronous Synchronous or
Asynchronous Synchronous or
Asynchronous Synchronous or
Asynchronous
Devices per SCSI
Channel Up to 15 Wide
SCSI devices Up to 15 Wide
SCSI devices Up to 15 Wide
SCSI devices Up to 15 Wide
SCSI devices
SCSI Channels 1 2 2 4
SCSIDataTransfer
Rate Up to 320
Mbytes/s per
channel
Up to 320
Mbytes/s per
channel
Up to 320
Mbytes/s per
channel
Up to 320
Mbytes/s per
channel
SCSI Bus LVD or SE LVD or SE LVD or SE LVD or SE
Other manuals for MegaRAID 320
2
Table of contents
Other LSI Adapter manuals

LSI
LSI LSISAS3442E-R User manual

LSI
LSI SAS 9300-8i User manual

LSI
LSI MegaRAID SATA 150 User manual

LSI
LSI MegaRAID SATA 150 User manual

LSI
LSI SAS 9207-8e User manual

LSI
LSI MegaRAID 8480 User manual

LSI
LSI LSISAS3080X-R User manual

LSI
LSI LSISAS9211-4i User manual

LSI
LSI SAS3442X User manual

LSI
LSI LSI20320IE User manual