ABuilding Safety. Building Security.
Remote Tableau Drive Unit
PTU288-1 and Accessories
Description
The Remote Tableau Drive Unit PTU288-1 allows to op-
tically signal events of a Fire Detection Control Panel
Series BC216 or BC016, or of an Extinguishing Control
Panel Series LC216, on an optional synoptic remote
tableau. In addition, a built-in buzzer signals the alarm
or fault condition of the control panel.
Up to 3 LED Display Fields LAB48 or LED Connection
Modules LAM48-1 can be connected to the remote tab-
leau drive unit in any combination.
In accordance to the parameterisation, the LEDs can be
used to display the conditions of detectors, detector zo-
nes, actuations, actuation elements, alarming devices,
transmitting devices, extinguishing systems or fl ooding
zones as well as the most important system conditions
of the fi re detection control panel (e.g., summary alarm,
fault condition or disablement condition). If needed, it is
also possible to combine several events into a summary
display.
Furthermore, the PTU288 has 5 freely parameterisable
control inputs.
The remote tableau drive unit is connected to the fi re
detection control panel via the INFO bus. Auxiliary mo-
dules are not needed for connection to Control Panels
Series BC216. A Serial Interface Module SIM016-3 is
necessary for connecting the PTU288 to a Fire Detec-
tion Control Panel Series BC016.
The PC software PARSOFT is used to parameterise the
remote tableau drive unit via the USB interface.
The componentry is prepared for direct installation into
the LED Display Tableau LAT288-1 or LAT288-1CE. The
componentry can also be mounted in any housing in the
LST standard grid, using the supplied mounting parts.
• Optically and acoustically signals
the events of a fi re detection or
extinguishing control panel
• Actuation of up to 144 LED pairs,
single LEDs or relays
• Single or summary indication
parameterisable
• Connection to the INFO bus
• Easy parameterisation by means of
PC software PARSOFT
Specifi cations
Operating voltage 15 – 31VDC
Current consumption at 24V typ. 15mA (without LED modules)
Ambient temperature -20°C to +60°C
Dimensions L × W × H 150 × 75 × 20 (mm)
Weight 76g
Order number 252012
Order name Remote Tableau Drive Unit PTU288-1
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
PTU288-1_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
LED Connection Module LAM48-1
The LED Connection Module LAM48-1 serves, as auxili-
ary module of a Remote Tableau Drive Unit PTU288-1,
to actuate up to 48 single LEDs, or relay outputs of a
Relay Module RL58-1 or RL58-2, in any combination. In
this way graphical orientation tableaus for signalling the
events of a fi re detection or extinguishing control panel
can be easily designed.
The events are assigned to the individual LEDs or relay
outputs by parameterising the remote tableau drive unit
by means of PARSOFT.
The signals are available on pin connectors, which are
prepared for connecting assembled LED cords. The
fi rst 16 outputs are routed in parallel to two fl at cable
connectors. Relay Modules RL58-1 or RL58-2 can be
directly connected to each of these two fl at cable con-
nectors. If more relay outputs are needed, 2-wire con-
nection cords can be used to actuate 2 further relays
each.
The componentry is delivered with the material needed
for mounting in the LST standard grid.
Specifi cations
Operating voltage 15 – 31VDC (supply through PTU288-1)
Current consumption at 24V typ. 3mA (quiescent)
max. 80mA (lamp test, 48 LEDs connected)
Ambient temperature -20°C to +60°C
Dimensions L × W × H 135 × 75 × 15 (mm)
Weight 62g
Order number 252013
Order name LED Connection Module LAM48-1
LEDs Assembled Green/Red/Amber
The package contains 10 light emitting diodes with as-
sembled connection cords, which serve to easily con-
nect and mount the LEDs on a synoptic remote tableau
in a time-saving way.
There is a luminous LED at one end of the cord. The
2-pin connector at the other end of the cord is connec-
ted to the pin connector of the LED Connection Module
LAM48-1.
The LED can be easily mounted by means of the sup-
plied black plastic clip.
Specifi cations
Operating voltage Supply through LED Connection Module LAM48-1
Length of LED cable 2m
LED ø 5mm
Drillled hole for LED clip ø 6.3 – 6.5mm
Thickness of front panel max. 2mm
LEDs Assembled Green
Order number 259011
Order name LED Assembled Green/10pcs. LED-GN/10
LEDs Assembled Red
Order number 259010
Order name LED Assembled Red/10pcs. LED-RT/10
LEDs Assembled Yellow
Order number 259012
Order name LED Assembled Yellow/10pcs. LED-GE/10
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
PTU288-1_DBL_LST_EN_0804.PDF • PAGE 3
ABuilding Safety. Building Security.
LED Connection Cord
The 2-wire connection cord serves to connect light
emitting diodes or relays to the LED Connection Mo-
dule LAM48-1. The cord is needed if other than the
pre-assembled LEDs are used, or if more than two Re-
lay Modules RL58-1 or RL58-2 – which can be directly
connected to the LED connection module via fl at cable
– have to be actuated.
At one end of the cord there is a connector which fi ts
to the pin connector of the LED Connection Module
LAM48-1, and the other end of the cord is open.
Specifi cations
Line length 2m
Order number 259013
Order name Cord 2-Wire for LED Connection/10pcs. LED-LEITUNG-10

This manual suits for next models

1

Popular Network Card manuals by other brands

Linksys WGA600N - Wireless-N Gaming Adapter Bridge Quick installation guide

Linksys

Linksys WGA600N - Wireless-N Gaming Adapter Bridge Quick installation guide

Cervoz MEC-LAN-M102i user manual

Cervoz

Cervoz MEC-LAN-M102i user manual

Delta Electronics Function Card DVP-EH instruction manual

Delta Electronics

Delta Electronics Function Card DVP-EH instruction manual

StarTech.com ST20000SPEXI quick start guide

StarTech.com

StarTech.com ST20000SPEXI quick start guide

IMC Networks iMcV-T1/E1/J1-LineTerm Operation manual

IMC Networks

IMC Networks iMcV-T1/E1/J1-LineTerm Operation manual

Nortel Agent Greeting NTVQ09BA installation guide

Nortel

Nortel Agent Greeting NTVQ09BA installation guide

Linksys LINKSYS WMP300N user guide

Linksys

Linksys LINKSYS WMP300N user guide

Emerson Liebert OpenComms-485 reference guide

Emerson

Emerson Liebert OpenComms-485 reference guide

TRENDnet TE100-S4PCI Specifications

TRENDnet

TRENDnet TE100-S4PCI Specifications

Belkin F5D6001 user manual

Belkin

Belkin F5D6001 user manual

Linksys Compact USB 2.0 user guide

Linksys

Linksys Compact USB 2.0 user guide

METRObility Optical Systems RADIANCE R231-13 Installation and user guide

METRObility Optical Systems

METRObility Optical Systems RADIANCE R231-13 Installation and user guide

IBM 10GBE Product guide

IBM

IBM 10GBE Product guide

Allied Telesis AT-2972SX Specifications

Allied Telesis

Allied Telesis AT-2972SX Specifications

Instar IN-LAN 500 Quick installation guide

Instar

Instar IN-LAN 500 Quick installation guide

Allied Telesis AT-2911SX/ST user guide

Allied Telesis

Allied Telesis AT-2911SX/ST user guide

Compaq 127453-B21 Quickspecs

Compaq

Compaq 127453-B21 Quickspecs

Linksys USB200M Quick installation

Linksys

Linksys USB200M Quick installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.