Lucasey THFSWADS2 User manual

Important! Please read all warnings and cautions before installing the mount.
Caution: Improper installaion of this wall mount may void the warranty on your monitor.
Caution: Wall attachment should be performed by qualified installers only, using construction methods prescribed
by authorized architects or engineers that comply to all applicable codes and standards.
The maximum weight of each monitor to be installed on the THFSWADS2 is 125Lbs. (56.8 Kg.)
Inspect all parts to make sure there is no shipping damage. Do not install if any parts are damaged.
Please call 1-800-LUCASEY or 1-510-534-1435 if you have any questions about this installation.
THFSWADS2
Double Stud Articulating Wall Mount
for 32" to 50" Flat Screens
A multi-position dual articulating arm for flat screens
up to 125 Pounds. Ideal for concealing cord connections
in the wall behind the flat screen. Designed to mount
to structures with 16"
C
L
wall studs. The monitor can
be pushed into or pulled away from the wall as needed.
The dual pivot points and relocatable wall arm position
allow for flexibility in monitor placement. The viewing
angle can be adjusted
45
for the best viewing angle.
Wood lag screws are provided for wood stud installations.
Toggle bolts are provided for metal stud installations.
Concrete anchor bolts can be ordered separately using
part number WMAAB6.
Open pattern of wall plate allows access holes to be cut
into wall.
THFSWADS2_Ins (2/10) ©2010 Lucasey Manufacturing Corporation, Oakland, California www.lucasey.com
Protected under one or more of these U.S. Patent numbers: 3,291,432 3,559,942 3,724,798 DES.270,689 4,613,109 4,878,645 4,852,842 DES.309,5624,973,023 5,169,114 5,255,884 5,310,152 5,522,576 5,621,614 Re.35,677 DES.398,834 5,826,384 5,941,492 5,964,068 6,060,661 6,102,398 6,158,704 6,454,116B1 6,761,276B2 6,806,425B1
Page 1 of 5
THFSWADS2 INSTALLATION INSTRUCTIONS

WARNING: Improper installation can result in serious personal injury. It is the responsibility of the installer to ensure
that all safety precautions are taken during the installation and that all safety features of the mount are properly utilized.
WARNING: The structure to which the mount is attached needs to be capable of supporting five times the stated load limit.
Additional reinforcement of the structure to which the mount is attached may be necessary and a certified architect
or engineer is needed to make this determination.
WARNING: Take into consideration the combined weight of the mount, the monitor and any auxiliary equipment when
determining the total load on the wall and mount.
WARNING: Do not place body parts between movable parts on the THFSWADS2 mount. The mount has pinch points that can
cause injury.
WARNING: Make sure that the screws used to attach the monitor to the mount are the appropriate size and length. An
assortment of monitor attaching screws is provided for convenience. The appropriate screws to use for mounting the
monitor are determined by the monitor manufacturer. Failure to use the screws recommended by the monitor manufacurer
can result in the montior dropping from the mount and/or damage to the electronic components inside the monitor.
Item List
Tools Required
THFSWADS2 Wall Bracket Assembly
THFSWADS2 Wall Arm
Top and Bottom Covers for Wall Bracket Assembly
Side Covers for Wall Bracket Assembly
3/8-16 x 9" Flanged Head Hex Bolt
3/8" Belleville Washers
3/8-16 Nylock Nut
5/16-18 x 2" Hex Button Head Screw
5/16-18 x 2-1/4" Hex Head Bolt
5/16" Flat Washers
5/16" Belleville Washers
5/16-18 Nylock Nuts
1/4-20 x 2" Hex Button Head Screw
1/4" Flat Washer
1/4" Belleville Washers
#8-32 x 3/8" Self Tapping Phillips Screws
#14 x 2-1/2" HWH Lag Screws
1 ...
1 ...
2 ...
2 ...
2 ...
4 ...
1 ...
1 ...
1 ...
3 ...
2 ...
2 ...
1 ...
1 ...
2 ...
4 ...
6 ...
1/8" Hex Wrench
9/16" Box Wrench or Socket Driver
1/2" Box Wrench or Socket Driver
7/16" Box Wrench or Socket Driver
Phillips Screw Driver
Table of Contents
Page 1 ... Title Page & Product Description
Page 2 ... Warnings, Item List & Tools Required
Page 3 ... Dimensional Drawings
Page 4 ... Installation Instructions for THFSWADS2
Page 5 ... Pivot Adjustment & Warranty
Protected under one or more of these U.S. Patent numbers: 3,291,432 3,559,942 3,724,798 DES.270,689 4,613,109 4,878,645 4,852,842 DES.309,5624,973,023 5,169,114 5,255,884 5,310,152 5,522,576 5,621,614 Re.35,677 DES.398,834 5,826,384 5,941,492 5,964,068 6,060,661 6,102,398 6,158,704 6,454,116B1 6,761,276B2 6,806,425B1
Page 2 of 5
THFSWADS2 INSTALLATION INSTRUCTIONS
THFSWADS2_Ins (2/10) ©2010 Lucasey Manufacturing Corporation, Oakland, California www.lucasey.com

1.9
"
4.0
"
2.0" Dia.
THFSWADS2 Front View
(with Covers in Place)
5.0
"
5.0
"
16.0
"
THFSWADS2 Wall Plate
(without Covers)
THFSWADS2 Side View
15.5"
0.5
"
THFSWADS2 Top View
(Max. Projection)
2.0"
0.5
"
THFSWADS2 Top View
(Min. Projection)
20
Note: Maximum Left &
Right Pivot will be limited
by the size of monitor and
projection from the wall.
THFSWADS2 Top View
(with 20
Pivot)
Protected under one or more of these U.S. Patent numbers: 3,291,432 3,559,942 3,724,798 DES.270,689 4,613,109 4,878,645 4,852,842 DES.309,5624,973,023 5,169,114 5,255,884 5,310,152 5,522,576 5,621,614 Re.35,677 DES.398,834 5,826,384 5,941,492 5,964,068 6,060,661 6,102,398 6,158,704 6,454,116B1 6,761,276B2 6,806,425B1
Page 3 of 5
THFSWADS2 INSTALLATION INSTRUCTIONS
THFSWADS2_Ins (2/10) ©2010 Lucasey Manufacturing Corporation, Oakland, California www.lucasey.com

1. Determine the proper height and viewing location for the
monitor taking into consideration the proper ceiling and head
clearance for the monitor being mounted. Also, consider
where the monitor pivot point location will be placed and the
final desired viewing angle for the monitor.
2. Find the location of the center of two wood studs 16"
appart using a stud finder. Using the THFSWADS2 Wall Bracket
as a template, mark the location for the six Wood Lag Screws.
3. Using a 1/8" Drill bit, drill the six pilot holes 2-3/4" deep
at the marked locations on the wall.
4. Attach the Wall Bracket to the wall using the provided
Wood Lag Screws or Toggle Bolt Machine Screws. Make
sure all the screws are tight before proceeding with the
remainder of the installation.
Wood Lag Screws are provided for 16" on center wood stud
installations. If installing onto metal studs, use our WMATB6
toggle bolt kit. If installing into concrete, use our WMAAB6,
concrete anchor bolt kit.
See http://www.lucasey.com for details and drawings of
all available mount accessories.
Wall Bracket Mounting
Wall Bracket
6Pcs. Lag Screws
1. Attach the Adaptor Plate to the THFSWADS2 Pivot Plate using
the provided 1/4" Nylock Nuts and Washers.
2. Make sure that all four nuts are tight before mounting the
monitor.
3. Check to make sure that the 5/16 & 3/8" nuts and bolts
are tight at each of the six mount pivot points. Adjust the
tension at each of these pivot points to make sure the
monitor will not move unintentionally once installed.
4. Follow the monitor attaching instructions specific to the
Adaptor Plate being used. Make sure that the proper monitor
attaching screws are used as specified by the monitor
manufacturer.
Adaptor Plate Attachment
2Pcs. Horizontal Covers
2Pcs. Vertical Covers
4Pcs. Self Tapping Screws
4Pcs. 1/4-20 Nylock Nuts
4Pcs. 1/4" Flat Washers
THFSUL Adaptor (Sold Separately)
1/4-20 Studs
Protected under one or more of these U.S. Patent numbers: 3,291,432 3,559,942 3,724,798 DES.270,689 4,613,109 4,878,645 4,852,842 DES.309,5624,973,023 5,169,114 5,255,884 5,310,152 5,522,576 5,621,614 Re.35,677 DES.398,834 5,826,384 5,941,492 5,964,068 6,060,661 6,102,398 6,158,704 6,454,116B1 6,761,276B2 6,806,425B1
Page 4 of 5
THFSWADS2 INSTALLATION INSTRUCTIONS
THFSWADS2_Ins (2/10) ©2010 Lucasey Manufacturing Corporation, Oakland, California www.lucasey.com

Wall Pivot Point
Middle Pivot Point
Monitor Pivot Point
Monitor Pivot Adjustment
1. Revove the top and bottom Horizontal Covers as shown
on Page 4 for the wall bracket installation.
2. Use a 9/16" box wrench or socket to tighten the 3/8"
bolts and nuts on the Wall and Middle Pivot Points. Tighten
the bolts and nuts until the desired arm movement tension is
achieved.
3. Use a 1/2" box wrench or socket to tighten the 5/16"
bolt and nut on the Monitor Pivot Point. Tighten the bolt
and nut until the desired arm movement tension is achieved.
LIMITED WARRANTY
LUCASEY MANUFACTURING CORPORATION MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED except that the goods sold under this agreement
shall be free of defects in materials and workmanship for a period of one year from the user's date of purchase. User assumes all risk and liability
resulting from the use of the goods, whether used singly or in combination with other goods. Lucasey Manufacturing Corporation neither assumes
nor authorizes any person to assume for it any other liability in connection with the sale or use of the goods sold and there are no oral agreements
or warranties collateral to or affecting this limited warranty. Lucasey Manufacturing Corporation will repair or replace defective parts or equipment
within one year of the date of purchase, at its option, provided the part or equipment is returned pre-paid to Lucasey Manufacturing Corporation's
plant. The repaired or replaced part shall be shipped to the user, FOB Lucasey Manufacturing Corporation's plant. NO allowance for outside labor
charges are implied within the terms of this limited warranty. Under no circumstances will Lucasey Manufacturing Corporation be responsible for
special, indirect or consequential damages. The remedies set forth in this Limited Warranty are exclusive and the liability of Lucasey Manufacturing
Corporation with respect to any contract of sale or anything done in connection therewith, whether in contract, in tort, under any warranty or
otherwise shall not, except as expressly provided herein, exceed the price of the equipment or part on which such liability is based. Any damage
caused by the improper use, operation beyond capacity, substitution of parts or equipment not approved by Lucasey Manufacturing Corporation,
improper packaging, failure to observe installation or other instructions, transit, or repair by one other than Lucasey Manufacturing Corporation,
will not be covered by and shall void this Limited Warranty.
Protected under one or more of these U.S. Patent numbers: 3,291,432 3,559,942 3,724,798 DES.270,689 4,613,109 4,878,645 4,852,842 DES.309,5624,973,023 5,169,114 5,255,884 5,310,152 5,522,576 5,621,614 Re.35,677 DES.398,834 5,826,384 5,941,492 5,964,068 6,060,661 6,102,398 6,158,704 6,454,116B1 6,761,276B2 6,806,425B1
Page 5 of 5
THFSWADS2 INSTALLATION INSTRUCTIONS
THFSWADS2_Ins (2/10) ©2010 Lucasey Manufacturing Corporation, Oakland, California www.lucasey.com
Table of contents
Other Lucasey Rack & Stand manuals

Lucasey
Lucasey LC200WDA User manual

Lucasey
Lucasey LC2X2WT Operational manual

Lucasey
Lucasey TH100200W User manual

Lucasey
Lucasey LC200WT User manual

Lucasey
Lucasey PCEC1417A User manual

Lucasey
Lucasey PCEC2410A User manual

Lucasey
Lucasey THFSUL2014 User manual

Lucasey
Lucasey PCEC2410B User manual

Lucasey
Lucasey LC200WA2 User manual

Lucasey
Lucasey LC200C9F User manual