Burner Pilot Tube Field Retro Kit Document Number 117950 Page 6 of 6
03/28/01 Lucks Food Equipment Company
Technical Support 800-526-0725 or 800-824-0696
Adjusting the Thermjet TJ50/100 Burner
R(M)15/20/30 Rack Ovens
To adjust the burner on a Lucks Rack Oven you need two special tools.
- Water Column gauge with a range of 0-10 inches W.C.
- Exhaust analyzer, Carbon Monoxide and Oxygen sensors
ADJUST GAS PRESSURE
Install a barbed fitting into the port on the manual gas valve just after the regulator. A tube must connect from the
fitting to the HIGH side of your gauge.
With the oven NOT running you should see a pressure of at least 6 inches W.C. Start the oven and verify that the
pilot and main burners fire on the TJ100 burner. While running, the gas pressure should be 4.5 inches W.C.
The regulator will have a lead seal you must cut to remove the cap and gain access to the adjusting screw. If
adjustments are required, adjust the regulator by turning the screw to get 4.5" W.C. while running. Turning the
screw counter-clockwise decreases the gas pressure.
Note: You may only cut this seal on initial installation without prior approval from the Lucks Company, and you
must notify Lucks technical support within 72 hours that you have done so. At all other times prior approval must be
obtained from the Lucks Company to cut security seals, or the equipment warranty may be voided.
AIR ADJUSTMENT
The air shutter is located inline with the flex tubing coming from the combustion fan. It has a bolt to lock it in place,
raise it to increase air, lower it to decrease air. The air shutter should not be raised any more than 3/8" above its
lowest point.
Look into the sight glass on the burner, you are looking for a blue flame with a large quantity of yellow. NOTE:
Very small adjustments make a large change at this point.
Using the exhaust analyzer place it into the exhaust BELOW the draft hood. It should be in the middle of the tube, at
the hottest spot. Note that you may have to drill a 3/8” hole into the exhaust ventilation. The settings you must get
are...
Carbon Monoxide (Co) = less than 50 PPM ( 0 is expected )
Oxygen (O2) = 6.5 to 7.5 percent O2
With the oven running adjust the air shutter to achieve the desired performance and exhaust results. Adjust the
shutter DOWN to decrease the air, which will INCREASE the flames heat. Watch the oxygen and Carbon Monoxide
results carefully, decrease the air until the Carbon Monoxide level begins to increase, then increase the air slightly
and stop.
If you have any questions, please call the Lucks Technical Support Hot Line at 800-526-0725
WARNING: Injury or death may result if the burner is allowed to operate with exhaust
levels of Carbon Monoxide greater than 50 PPM.