Lumascape LS411LED User manual

INSTALLATION INSTRUCTIONS
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
W www.lumascape.com.au
IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
DANGER
ISOLATE LUMINAIRE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
Luminaire can become very hot.
Use discretion in placement.
Ensure that installation complies
with local authority standards.
All connections must be kept
dry; failure to do so may result
in product reliability issues.
Screw seals and sleeve must be
fitted or warranty void.
LS6023
(ordered separately)
LS411
Surface Mount
Base
LS411
Adaptor Base LS6025
(ordered separately)
OR OR
LS411
Concrete Anchor /
Spike
See individual mounting accessory
instructions overleaf
1.
2. Terminate luminaire. Single colour, non-dimmable, mains-voltage
version depicted in example. Refer to wiring diagrams below
for details. Earth lug connection only required for mains voltage
version of luminaire.
Select the grommet to suit wiring conductors. For correct cable selection refer
to table on top right. Screw mounting base to mounting accessory or screw
directly to mounting surface using 4 screws provided (holes for mounting
screws may be supplied blind. Drill through as required with a 4.5 mm drill. A
screw must be used for each hole drilled to achieve IP67 rating.)
Surface Mount Base
IMPORTANT For All Mounting Options
Select a suitable power supply and locate centrally in relation to desired luminaire locations.
Use discretion in placement as luminaire can become very hot and may burn. Run conduit
and drill / cast holes as specified. Run cables. Maximum distance for remote drivers is 30 m
from the luminaire. Use table on right to select a suitable supply cable with the appropriate
number of conductors for the luminaire you are installing.
Single colour, low-voltage, non-dimmable 2
Single colour, low-voltage, dimmable 4
Single colour, mains-voltage, non-dimmable 3
Integral RGB driver 6
Remote RGB driver 6
E
Earth lug only required
for mains voltage
NOTE: Use only 1 x circular
cable to keep IP rating
SPOTLIGHT & FLOODLIGHT
LS411LED Omnio Mini
Warranty void if not installed as per installation instructions N653
LS411LED
Surface Mount Base
Pole Clamp (LS6023)
Signage System (LS6025)
Concrete Anchor / Spike
IP67
100-240 V AC, 50/60 Hz
24 V DC Ripple Free Supply
12 V AC Magnetic Transformer
Single Colour
Single Colour Dimming
RGB (Integral & Remote Driver)
NO POWER
TOOLS
KEEP AWAY FROM
FLAMMABLE MATERIAL
DO NOT USE SILICONE
ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE
FROM DIRT AND MOISTURE
DO NOT HOSE OR
PREASSURE CLEAN
see over for wiring diagrams

IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
To aim luminaire loosen socket head screw on the side of the knuckle, position
luminaire and retighten using the 5 mm Allen key supplied.
3.
0.5 Nm
5 Nm
IMPORTANT:
Attach screw seals
Peel back sleeve to
tighten screws
screw seal base
Sleeve must
meet base
Wiring Diagrams
Low Voltage Mains Voltage
Red Red +
Orange Red
-
Green Green +
White Green
-
Blue Blue +
Black Blue
-
White 1 AC1 +
White 2 AC2
-
Orange PWM Common
Red PWM Red
Green PWM Green
Blue PWM Blue
White 1 AC1 +
White 2 AC2
-
Orange PWM +
Red
Green PWM
-
Blue
White AC1 +
Black AC2
-
Black Active
Green Earth
White Neutral
JOIN
Surface Mount Base Continued...

IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
2. Use M4 x 10 mm screws to fit base
to bracket.
Secure bracket to pole (6 mm Allen key
required).
3. Fit grommet assembly (Required for IP rating).
1.
4.
Mark luminaire location on post and drill
clearance hole to suit cable used.
NOTE: Cable exit location is aligned central to
luminaire base.
Minimum pipe size
38 mm
(1.5 in)
PIPE SIZE RANGE
78 mm (3.0 in)
Maximum pipe size
Adaptor Base for Pole
5. 6.
Terminate luminaire. Mains-voltage version
depicted in example. Refer to wiring
diagrams below for details.
Aim luminaire. Refer to Surface Mount Base
section for lamping instructions.
NOTE: Use only 1 x circular
cable to keep IP rating
Wiring Diagrams
Low Voltage Mains Voltage
Red Red +
Orange Red
-
Green Green +
White Green
-
Blue Blue +
Black Blue
-
White 1 AC1 +
White 2 AC2
-
Orange PWM Common
Red PWM Red
Green PWM Green
Blue PWM Blue
White 1 AC1 +
White 2 AC2
-
Orange PWM +
Red
Green PWM
-
Blue
White AC1 +
Black AC2
-
Black Active
Green Earth
White Neutral
JOIN
EEarth lug only required
for mains voltage

IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
Base of luminaire
4x Screws/Bolts and Washers
to suit Ø8 mm hole required
2x screws to suit Ø5 mm hole required
Hole Centres
110 mm Square
150 mm Square
1220 mm
450 mm
Saddle
Conduit
Supply Cable
Mounting Stud
4x Screws/Bolts and Washers
to suit Ø8 mm hole required
Turnbuckle
Turnbuckle
2x Screws to suit 5 mm hole
1.
2.
3. 4.
1. Drill/cast holes and run cables as per lighting plan. Cable will need to exit the mounting surface
into the hollow of the signage pole.
2. Use discretion in placement as luminaire can become very hot and may burn.
3. Select/purchase appropriate stainless steel fasteners for mounting substrate. (Not supplied.)
1. Feed supply cable through pole until exiting mounting stud at the end.
2. Bolt signage pole to wall.
3. Open turnbuckle to approximately half of it’s adjustment range. Extend the rope assembly up the wall and fasten saddle in place.
4. Fit rope assembly to saddle and lightly adjust tension if required.
Remove base from luminaire and feed through
supply cable.
Screw luminaire base onto mounting stud.
Terminate supply cable.
Adaptor Base for Signage
NOTE: Use only 1 x circular
cable to keep IP rating

IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
Cable entry
4x Through
Holes
5. 6.
Seal cable entry point and 4 small
holes in base with silicone.
Finalise installation and aim as desired. Refer to Surface
Mount Base section for lamping instructions.
7. Finalise installation and aim as desired. Refer to Surface
Mount Base section for lamping instructions.
NOTE: Use only 1 x circular
cable to keep IP rating
Wiring Diagrams
Low Voltage Mains Voltage
Red Red +
Orange Red
-
Green Green +
White Green
-
Blue Blue +
Black Blue
-
White 1 AC1 +
White 2 AC2
-
Orange PWM Common
Red PWM Red
Green PWM Green
Blue PWM Blue
White 1 AC1 +
White 2 AC2
-
Orange PWM +
Red
Green PWM
-
Blue
White AC1 +
Black AC2
-
Black Active
Green Earth
White Neutral
JOIN
E
Earth lug only required
for mains voltage
Adaptor Base for Signage Continued...

IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
50 mm minimum
Attach protective sleeve.
Peel back when tighten screws.
1.
3. Adjust luminaire
and lock into place
5 Nm
0.5 Nm
5.
Concrete Anchor / Spike
Firmly push spike into ground ensuring base of
luminaire is at least 50 mm above soil level.
Connect top of luminaire to supply cables from mounting spike.
Refer to wiring diagram below for details.
2.
White 1 Red
White 2 Black
Orange Orange
Red
Green Grey
Blue
JOIN
White 1 White
White 2 Black
Orange Orange
Red Red
Green Green
Blue Blue
White White
Black Black
Orange Orange
Red Red
Green Green
Blue Blue
Black Brown
Green Green
White Blue
Black Black
White White
For mains voltage use as
concrete anchor only. Contractor
is to ensure installation complies
with local wiring rules.
Tighten screw to secure luminaire
to base. Connect luminaire cable in
accordence with local wiring rules.
See diagram below for details.
4.
Mains Voltage
Finished
surface
level
Conduit
Concrete
Wiring Diagrams
Wiring Diagrams
Low Voltage
Low Voltage
Mains Voltage
Red or White AC1 +
Black AC2
-
Orange (1) PWM + (optional)
Grey (1) PWM
-
(optional)
(1) Do not connect if dimming is not required
White AC1 +
Black AC2
-
Brown Active
Green Earth
Blue Neutral
Red Red +
Orange Red
-
Green Green +
White Green
-
Blue Blue +
Black Blue
-
White AC1 +
Black AC2
-
Orange PWM Common
Red PWM Red
Green PWM Green
Blue PWM Blue

IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
WARNING - To reduce the risk of FIRE or INJURY:
1. Luminaires and transformers to be installed by licensed electrical contractors.
2. Luminaires to be used for intended purpose only.
3. Do not operate the luminaires with a missing or damaged parts.
4. Use only genuine Lumascape parts to replace damaged or missing components.
5. Refer to instructions for installation and operating requirements.
6. Ensure installation complies with local regulations
Voltage insulation test (megger) will permanently damage product and will void warranty.
SAVE THESE INSTRUCTIONS.
SAFETY INSTRUCTIONS
Questions?
Call +61 7 3286 2299
Email [email protected]
www.lumascape.com.au
Table of contents
Other Lumascape Dj Equipment manuals