LUX LUMEN 10717 User manual

Fiber Source
White light
Order code: 10717

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.2/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
CONTENTS
1PICTURE.....................................................................................3
1.1 GENERAL....................................................................................... 3
2DIMENSIONS ...............................................................................4
3SAFETY INFORMATION ...................................................................5
3.1 SYMBOLS ...................................................................................... 5
3.2 PROTECTION FROM ELECTRIC SHOCK ....................................................... 6
3.3 PROTECTIONS FROM FIRE AND BURNS...................................................... 6
3.4 PROTECTION FROM INJURY .................................................................. 7
3.5 DISPOSING OF THIS FIBER SOURCE........................................................ 7
4PHYSICAL INSTALLATION................................................................8
4.1 UNPACKING.................................................................................... 8
4.2 LOCATION AND ORIENTATION ............................................................... 8
4.3 MOUNTING..................................................................................... 8
4.4 ASSEMBLING FIBERS ......................................................................... 8
5EXTERNAL CONNECTIONS...............................................................9
5.1 DC POWER INPUT ............................................................................. 9
6EMC AND SAFETY REQUIREMENTS ..................................................10
7INSTALLATION SETUP ..................................................................11
7.1 SPECIFICATION.............................................................................. 11
8SERVICE AND MAINTENANCE .........................................................12
8.1 SAFETY PRECAUTIONS ...................................................................... 12
8.2 CLEANING.................................................................................... 12
9WARRANTY ...............................................................................13
9.1 APPLICATION OF WARRANTY............................................................... 13
9.2 RMA PROCEDURE ........................................................................... 15
10 LIST OF USED ABBREVIATIONS .......................................................16

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.3/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
1Picture
1.1 General
Fiber Source
Fiber Source with fiber

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.4/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
2Dimensions
Total length from cooling pins to swivel M25: 123mm

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.5/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
3Safety information
Before installing, powering up, or servicing the Fiber Source, it is highly
recommended that you read this manual and ensure yourself that you
completely understand its content. Observe the safety precautions in this
manual. Install and operate the led-unit only as described in this manual,
and in conformity with local regulations. If you have any questions how to
operate this Fiber Source safely, please contact your point of sale.
3.1 Symbols
Following symbols are used to identify important safety information on the
Fiber Source and in this manual.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.6/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
3.2 Protection from electric shock
Although this device itself does not operate with dangerous voltages, the
installation in which it is intended to be used, can contain dangerous
voltages.
Shut down the power of the complete installation before carrying out any
installation, or maintenance work.
Use only AC to DC power sources, suitable for the application, and conform
to local regulations. Please ensure yourself that the AC to DC power supply
is able to deliver the rated current requirements of the installation.
If any cable, seal or housing is damaged, cracked, or reformed, disconnect
the power of the installation immediately.
For any additional servicing, not described in this manual, please contact
your point of sale.
3.3 Protections from fire and burns
Do not operate this led-unit if ambient temperature is over 45 °C (113°F).
Please ensure yourself that sufficient ventilation around the led-unit is
possible.
It might be necessary to allow the led-unit to cool down for 5 minutes,
before servicing.
Do not modify the led-fixture, in a way, not described in this manual.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.7/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
3.4 Protection from injury
Ensure yourself that the led-unit and all its accessories are securely
fastened. Verify that the led-unit is firmly fixed to its supporting
underground.
3.5 Disposing of this Fiber Source
This led-lighting device is manufactured in compliance with directive of the
European community: waste electrical and electronically equipment. Please
help to preserve our environment and ensure that this Fiber Source will be
recycled properly at the end of its life.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.8/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
4Physical installation
Thank you for selecting this Fiber Source as best solution in your setup.
Warning! Read the safety precautions in this manual before integrating this
led-unit into your installation.
Installation must be carried out by qualified professionals only.
Assure yourself that there is sufficient and unrestricted air flow around the
Fiber Source.
4.1 Unpacking
The following items are included in your package:
•Led-fixture with focussing bracket included
•Protective antistatic packaging, with short form manual
4.2 Location and orientation
This led-unit can be used in all directions.
4.3 Mounting
The Fiber Source can be mounted on all kind of non-combustible materials
but take in consideration that the module can have a Tc of approximately
30 °C higher as ambient temperature.
In case of problems, or doubts, please contact your point of sale.
4.4 Assembling Fibers
Insert the fused bundle of fibers, in the swivel.
By moving the fibers more or less towards the LED source, the optimal light
efficiency can be obtained.
When at the desired position, lock the swivel.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.9/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
5External connections
5.1 DC power input
Safety precautions
Never connect the live power on the input terminals of the Fiber Source!
In case of doubts, contact your point of sale.
Polarity
The Fiber Source is polarity sensitive. So observe polarity and cabling:
•Red inner conductor = positive
•Black inner conductor = negative
Improper connection might damage the Fiber Source and power supply
permanently. In case of inversed polarity, the warranty is void.
Power supply: Rated current
Cable
Cable type Omerin 2x0,25mm
Red
+700mA
Black
Ground
Please ensure yourself that the cable end is watertight sealed at the
connection. If this is not properly done, water can pass through the inner
conductors of the cable and damage the internal electronics of the Fiber
Source.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.10/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
6EMC and safety requirements
The Fiber Source is fully compliant to the LVD and EMC directive of the
European council, if used in a properly designed setup.
The Fiber Source is only intended to be used in lighting applications, and as
such, the complete assembly of led-unit and power supply needs to be fully
compliant with following harmonized standards:
LVD requirements of the power supply
•EN 60598: general requirements of lighting equipment.
EMC requirements of the power supply
Immunity according to:
•EN 61547:2009 (General EMC immunity requirements lighting eq.)
•EN 61000-4-1:2006 (General immunity testing techniques)
•EN 61000-4-2:2008 (ESD immunity test)
•EN 61000-4-3:2006 + A1:2007 (Radiated immunity test)
•EN 61000-4-4:2004 (Fast transients and burst immunity)
•EN 61000-4-5:2005 (Surge immunity test)
•EN 61000-4-6:2008 (Conducted immunity test)
•EN 61000-4-8:1993 (Magnetic field immunity test)
•EN 61000-4-11:2004 (Voltage variations immunity test)
•EN 61000-6-1:2005 (Generic standards for immunity)
Emission according to:
•EN 61000-3-2:2005+A1:2008+A2:2009 (Harmonics emission
test<16A)
•EN 61000-3-3:2008 (Flicker+ voltage changes limits< 16A)
•EN 55015:2006+A2:2009 (Conducted + radiated emission lighting
equipment)
To achieve this compliance, a proper power supply must be supplied. In
case of doubts, contact your point of sale.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.11/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
7Installation setup
7.1 Specification
The Fiber Source has a black anodized aluminum housing with a M25
Swivel with a total length of 12cm
•Power consumption: 12W
•Input current: +700mA
•Mechanical connection: Bracket
•Led-color: White:
2700K/3000K/4000K/5700K, CRI 80 (CRI 90 on request)
•With collimator optic inside.
•Ingress protection: IP20
•Maximum operating temperature: -20°C to 40°C
•Maximum storage temperature -30°C to 50°C
•Dimensions: Ø65mm (width swivel included 85mm) x L123mm
Height of bracket 75mm
Total width including bracket: 70mm
•Weight: approximately 0,4kg

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.12/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
8Service and Maintenance
8.1 Safety precautions
Read carefully the safety information in this manual. Lock out the power on
the entire system and allow all electronic devices to discharge, and cool
down, before executing any service or maintenance.
8.2 Cleaning
The Fiber Source itself
Extensive dirt, and particle build-up degrades performance, may cause
overheating can result in damaged led-unit and power supplies. Damage by
inadequate cleaning or maintenance is not covered by the Fiber Source
warranty.
Never use solvents to clean the outer housing of the unit.
Never use water, or wet cloth.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.13/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
9Warranty
9.1 Application of warranty
Warranty period
Warranty service is valid for one year from the date of purchase by the
consumer, as evidenced by invoice date given out by your point of sale.
Warranty service
Service under warranty can only be done by Lux Lumen.
Coordinates:
Lux Lumen
Kernenergiestraat 53 A
2610 Wilrijk
Belgium
Any cost of secure transportation of the Fiber Source to and from Lux
Lumen service department, will be borne by the customer.
Limitations
Lux Lumen will not warrant the following:
•Periodic check-ups, maintenance and repair or replacement of parts
due to normal wear and tear.
•Consumables
•software
•Defects caused by modifications carried out without Lux Lumen’s
approval.
•Damage resulting from the fact that a Fiber Source is not conforming
to country specific standards or specifications in another country that
the country of purchase.
Costs incurred by Lux Lumen’s service center in making any adoptions or
modifications of a Fiber Source necessary for country specific technical or
safety standards or specifications, or any other cost to adjust the Fiber
Source as a result of any specifications which have changed since the
delivery of the Fiber Source.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.14/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
Warranty service is excluded if damage or defects have been caused by:
Improper use, extensive use, handling or operation of the Fiber Source as
referred to in the user manual or operator manual and/or relevant user
documents, including without limitation, incorrect storage, dropping,
excessive shocks, corrosions, dirt, water, or sand damage, if the Fiber
Source is not rated to be used in severe conditions, indicated by its IP and
IK degree, mentioned in the Fiber Source specifications in this manual.
Repairs, modifications or cleaning carried out by a non Lux Lumen service
centre.
Use of spare parts, software or consumables, which are not compatible
with the Fiber Source.
Connecting the Fiber Source to equipment not intended to be used with this
Fiber Source.
Defects caused by improper condition of the power supply network.
Inadequate packaging of the Fiber Source when returning it under the RMA
procedure.
Accidents or disasters or any cause beyond the control of Lux Lumen,
including but not limited to lightning, water, fire, public disturbances,
improper ventilation, and acts of god.
For full details of the warranty offered on this Fiber Source, please contact
Lux Lumen’s service center.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.15/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
9.2 RMA procedure
To send material back to Lux Lumen, you need a RMA (Return Material
Authorization) document that you will receive from Lux Lumen.
Without the RMA document, we cannot accept the material.
The procedure to obtain a RMA:
Step 1:
Customer contacts Lux Lumen about warranty, defects if material has to be
returned.
Step 2:
Lux Lumen sends the customer a filled out RMA document (using a unique
RMA number)
Step 3:
Customer sends material (include a copy of the RMA document with the
material)
Step 4:
Lux Lumen evaluates the problem, and informs the client if repair is done
under warranty, or makes an offer to the client for repair.

PRODUCT NAME LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.16/16
MODEL T: +32 3 293 35 50 –www.lux-lumen.com
10 List of used abbreviations
•AC: Alternating current
•DC: Direct current
•°F: Temperature in degrees Fahrenheit
•°C: Temperature in degrees Celsius
•LED: Light Emitting Diode
•CRI: Color Rendering Index
•RGBW: Red Green Blue White
•FWHM: Full Width Half Measurement
•RMA: Return Material Authorization
•PWM: Pulse Width Modulation
•LVD: Low Voltage Directive
•EMC: ElectroMagnetic Compatibility
Table of contents
Other LUX LUMEN Dj Equipment manuals