LUX KONOz User instructions

Installation Settings Guide
In this guide we will describe the advanced
installation settings that you can access from
KONOz’s main menu. We recommend that
an HVAC service professional uses these settings
to fine-tune your thermostat’s performance for
your home.
You can access the installation settings by going to
the main menu and selecting the gear icon. You
will see “IS” on the screen and will be prompted to
select “yes” or “no”. Select “yes” to access the
installation settings. Rotate the knob to view
settings and press the knob to confirm.
Once in the installer settings, rotate the knob to
change a setting value. Press the knob to confirm
the new value and proceed to the next option.
There are three ways to exit the settings:
1. Continue through the remaining settings until you
pass setting 99.
2. Press and hold the knob for 3 seconds after you
confirm any changes to your settings.
3. Wait 60 seconds after you confirm any changes
to your settings.
Installation Settings Guide
System Type & Configuration
You will first see your current system type and configuration – confirm by pressing the knob
and then you will begin navigating through the available settings.
HVAC system type
F = Furnace
HP = Heat Pump Available System
Modes
HVAC system subtype
Furnace Systems
ELEC: Electric fan. Thermostat calls fan
to run with heat
GAS: Gas fan. Thermostat does not call
fan to run with heat
BOIL: Boiler. No fan connected to
heating system
Heat Pump
o: Changeover valve = O
b: Changeover valve = B
All manuals and user guides at all-guides.com
all-guides.com
-01 Temperature Format
F for Fahrenheit C for Celsius
Use this setting to select your preferred temperature format.
-02 Temperature Calibration
Installation Settings Guide
KONOz is factory calibrated, but you can use this setting to adjust the temperature
sensor for your home. The screen will alternate between your calibration temperature and the
offset value – to remove calibration, make sure that the offset value is set to 0.
-03 Available HVAC Modes
Heat Only Heat & Cool
KONOz uses terminal detection to identify your system type and you can use this
installation setting to view and change the available modes. Use this setting to view and/or
change the different modes available depending on your system type. Rotate the knob to see
various options and configurations for your system.
Cool Only
All manuals and user guides at all-guides.com
Installation Settings Guide
-04 Maximum Heat Limit
Default Temperature: 90°F
Use this setting to set a maximum temperature limit for your heating system. The limit can be
as high as 90°F (32°C) or as low as 60°F (15°C). *Note: Not available for cool only systems
-05 Minimum Heat Limit
Default Temperature: 45°F
Use this setting to set a minimum temperature limit for your heating system. The minimum
heat limit range is from 60°F (15°C) to as low as 45°F (7°C). *Note: Not available for cool
only systems
-06 Maximum Cool Limit
Default Temperature: 95°F
Use this setting to set a maximum temperature limit for your cooling system. The maximum
cool limit range is dependent on your heating limits.
All manuals and user guides at all-guides.com
Installation Settings Guide
-07 Minimum Cool Limit
Use this setting to set a minimum temperature limit for your cooling system. The minimum
cool limit range is dependent on the values you entered for your heating and cooling limits.
-08 System Type
Use this setting to modify the system type. The available options include Gas Furnace, Electric
Furnace, Boiler (No Fan) and Heat Pump. See step 09 below for additional options when
selecting Heat Pump.
-09 System Type - Heat Pump
If you selected heat pump during #8, you will then have to select your valve type in #9. Select
O or B depending on your valve type. B will energize the B/O terminal in heat mode and O
will energize the B/O terminal in cool mode.
Gas Furnace Electric Furnace Boiler (No Fan)
Heat Pump Option O Valve B Valve
Default Temperature: 50°F
All manuals and user guides at all-guides.com
Installation Settings Guide
-10 Minimum On/Off Time
-11 Temperature Swing
Use this setting to set a swing value. Your swing setting determines how far the ambient
Temperature can deviate from the set temperature before KONOz turns on your heating
or cooling system. You can select 0, .25°, .5°, 1° or 2.25°.
Use this setting to set a standby time so that your HVAC systems can safely and efficiently
switch on and off. You can either select a 5-minute or a 2-minute off time. During normal
operation, the hourglass icon indicates that the minimum off time is temporarily preventing
your heating and cooling system from turning on.
-12 Stage 2 Heating Offset (for conventional systems)
Use this setting to set a value that your thermostat will use to decide when to turn on your
second stage of heating. You can select Off, 1, 2, 3, 4 or 5 degrees F.
Off, no second stage heat 1° 5°
All manuals and user guides at all-guides.com
Installation Settings Guide
-13 Stage 2 (Auxiliary) Heating Offest (for heat pump systems)
Use this setting to set a value that your thermostat will use to decide when to turn on your
second stage of heating. You can select Off, 1, 2, 3, 4 or 5 degrees F.
-14 Clock Format
12 Hour AM/PM Display 24 Hour Time Display
Use this setting to choose between 12-hour am/pm time display or 24-hour time display.
*Note: This setting not available with battery-only power.
-15 Backlight
Use this setting to choose between a backlight auto-off setting of 10 seconds or an always-on
backlight. When the backlight is turned off the display will not be visible. Press the knob
to turn on the display. *Note: This setting not available with battery-only power.
Off, no second stage heat 1° 5°
10 Seconds Always On
All manuals and user guides at all-guides.com
all-guides.com
Installation Settings Guide
-16 Filter Life
Off 30 Days
Use this setting to turn on and set a value for your air filter’s lifespan. You’ll then be able to check
its remaining lifespan in the fan settings sub-menu. (You can select Off, 30, 60, 90, 120, 180 or 365 days).
365 Days
-98 Compressor Bypass
Use this setting to temporarily disable the minimum on/ off time protection. If you set
compressor bypass protection to ‘yes’ then your system will switch heating and cooling on/off
without waiting for the minimum on/off time.
Compressor Bypass On Compressor Bypass Off
-99 Factory Reset
Reset KONOz Do Not Reset KONOz
Use this setting to initiate a factory reset and to setup your KONOz from scratch.
All manuals and user guides at all-guides.com
Installation Settings Guide
We’re here to help! Please contact our customer support team for assistance:
PHONE:
LIVE CHAT:
EMAIL:
VIDEOS:
SUPPORT HOURS:
856.234.8803
LuxProducts.com/support
techsupport@luxproducts.com
LuxProducts.com/Videos
8am to 6pm EST, Monday - Friday
For wiring diagrams, please reference the appendix
section of the KONOz Manual
Lock: Press and hold the knob for 10 seconds on the main run screen to lock local
control of KONOz. When locked, press and hold the knob for 10 seconds
to unlock.
Power Cycle: Remove KONOz from its base and locate the black reset
button on the back of the thermostat. Press and hold this button for 3 seconds
to fully power cycle the device.
EMER Heat: If you have a Heat Pump system with stage 2 (auxiliary) heat
enabled, you can select EMER heat from the mode menu. When this is enabled,
the thermostat will not use the compressor heating stage and will use the
auxiliary heating stage as the only heat source.
-Additional Features
LUX Products - Designed in Philadelphia
All manuals and user guides at all-guides.com

Other manuals for KONOz

1

Other LUX Thermostat manuals

LUX ELV4d User manual

LUX

LUX ELV4d User manual

LUX SMART TEMP TX500b Series User manual

LUX

LUX SMART TEMP TX500b Series User manual

LUX TX1500B SERIES User manual

LUX

LUX TX1500B SERIES User manual

LUX ELV1/PSPLV510 User manual

LUX

LUX ELV1/PSPLV510 User manual

LUX TX500E User manual

LUX

LUX TX500E User manual

LUX PSP511Ca User manual

LUX

LUX PSP511Ca User manual

LUX T20-1141SA User manual

LUX

LUX T20-1141SA User manual

LUX DMH110b User manual

LUX

LUX DMH110b User manual

LUX TX100E User manual

LUX

LUX TX100E User manual

LUX TX100Ea User manual

LUX

LUX TX100Ea User manual

LUX KONOz User manual

LUX

LUX KONOz User manual

LUX CS1 User manual

LUX

LUX CS1 User manual

LUX KONOzw User manual

LUX

LUX KONOzw User manual

LUX ELV4 Operating instructions

LUX

LUX ELV4 Operating instructions

LUX DMH110b User manual

LUX

LUX DMH110b User manual

LUX CAG1500 Series User manual

LUX

LUX CAG1500 Series User manual

LUX T10-1143SA User manual

LUX

LUX T10-1143SA User manual

LUX TX9100Ua SMART TEMP User manual

LUX

LUX TX9100Ua SMART TEMP User manual

LUX LP0511D User manual

LUX

LUX LP0511D User manual

LUX KONO User manual

LUX

LUX KONO User manual

LUX 120-1141 User manual

LUX

LUX 120-1141 User manual

LUX CS1 User manual

LUX

LUX CS1 User manual

LUX TX9600TS User manual

LUX

LUX TX9600TS User manual

LUX SMART TEMP TX9100U User manual

LUX

LUX SMART TEMP TX9100U User manual

Popular Thermostat manuals by other brands

RST IQ777 instruction manual

RST

RST IQ777 instruction manual

Aprilaire 8840 Safety & installation instructions

Aprilaire

Aprilaire 8840 Safety & installation instructions

Trane XL824 user guide

Trane

Trane XL824 user guide

ABB -i-Bus-KNX Millenium Reference manual

ABB

ABB -i-Bus-KNX Millenium Reference manual

Emerson Sensi Control guide

Emerson

Emerson Sensi Control guide

Tech Controllers EU-292 v2 user manual

Tech Controllers

Tech Controllers EU-292 v2 user manual

Siemens RDD100.1DHW operating instructions

Siemens

Siemens RDD100.1DHW operating instructions

AMX ENV-VST-C user guide

AMX

AMX ENV-VST-C user guide

Regin TM1-P Instruction

Regin

Regin TM1-P Instruction

Honeywell Home Round Smart Thermostat Professional install guide

Honeywell Home

Honeywell Home Round Smart Thermostat Professional install guide

Vector TLC3-ECO Series manual

Vector

Vector TLC3-ECO Series manual

TOTALINE CPV220LA owner's manual

TOTALINE

TOTALINE CPV220LA owner's manual

RCS TR65 installation manual

RCS

RCS TR65 installation manual

jablotron TP-155 manual

jablotron

jablotron TP-155 manual

Carrier 33CS Installation and operating instructions

Carrier

Carrier 33CS Installation and operating instructions

Computherm q3rf operating instructions

Computherm

Computherm q3rf operating instructions

American Standard ASYSTAT656 Operation guide

American Standard

American Standard ASYSTAT656 Operation guide

Glen Dimplex Nordic AS Nobo R80 PDE-N User instruction

Glen Dimplex Nordic AS

Glen Dimplex Nordic AS Nobo R80 PDE-N User instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.