M8BS2-042
P. 1 / 3EM-5478-2 Rev.3
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Installation base.......................................................(1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• This equipment is suitable for use in a Pollution Degree 
2 environment and in Installation Category II, with the
maximum operating voltage 300V.
Basic insulation is maintained between the input and output.
Prior to installation, check that the insulation class of this 
unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• The  equipment  must be installed such that  appropriate 
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformity.
■ POWER INPUT RATINGS
•  Power  input  ratings  are  specied  by  the  model  number 
suffix code. Check the power input voltage for the unit on
the specification label.
AC power: 100 – 240V AC rating: 85 – 264V, 47 – 63 Hz,
130VA min.
DC power:  24 V DC rating: 24V ±10%, 2,5A min.
■ ENVIRONMENT
• Indoor use
• When  heavy  dust  or  metal  particles  are  present  in  the 
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous 
vibration.  Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C or 32 
to 131°F (0 to 50°C or 32 to 122°F for AC power) with relative 
humidity within 30 to 90% RH (30 to 85% RH for AC Power) 
in order to ensure adequate life span and operation.
•  Be  sure  that  the  ventilation  slits  are  not  covered  with 
cables, etc.
■ WIRING
• Do not install cables (power supply, input and output) close 
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises 
are present.  Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is supplied, 
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■ REAR VIEW
INSTALLATION BASE
(for Network interface) MODEL
M8BS2-042
INSTRUCTION MANUAL
MOUNTING REQUIREMENTS mm (inch)
230 (9.06)
4–M5 SCREW
50 (1.97)
Specifications
M8BS2-042
P. 2 / 3EM-5478-2 Rev.3
TERMINAL CONNECTIONS
Connect the unit referring the drawings below and the connection diagrams in the following page.
■EXTERNAL DIMENSIONS mm (inch)
• M8BS2-042-M2
CH1 CH4
1 2 34
+–+–+–+–
7.3(.29)
16–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
3
4
5
2
1
V.ADJ +–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
156 (6.14)
132 (5.20) 26 (1.02) min.
AC POWER UNIT
5–M3.5 POWER
TERMINALS
6.6 (.26)
• M8BS2-042-R
CH1 CH4
1 2 34
+–+–+–+–
7.3(.29)
16–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
+–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
132 (5.20) 26 (1.02) min.
3–M3.5 POWER
TERMINALS
123
92 (3.62)
POWER LED
8.6 (.34)
M8BS2-042
P. 3 / 3EM-5478-2 Rev.3
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2)  Power  input  voltage:    Check  voltage  across  the  power 
terminals.
3) Installation & environment
MAINTENANCE
Power units' standard life is expected for 10 years with aver-
age ambient temperature 35°C (95°F) and 1.0A load.  Contact 
M-System for use in extremely different conditions.
■
HOW TO REPLACETHE POWER UNIT (power suffix code: M2)
1)  Prepare Power Unit (switching regulator) model HDC10.
2)  Turn off the power supply connected to the Power Unit.
3)  Remove  the  wire  binding  and  wiring  connected  to  the 
terminal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(4 places).
5)  Detach the Power Unit from the Installation Base.
6)  Attach the new Power Unit to the Installation Base and 
tighten the screws in reverse order as explained above.
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT +
–
+
–
OUTPUT 2 OUTPUT 2
Ch.4
OUTPUT
POWER
+
-
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT +
–
+
–
OUTPUT 2 OUTPUT 2
Ch.4
OUTPUT
POWER
+
-
■ CONNECTION DIAGRAM
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
3
4
5
2
1
V.ADJ
AA
A
A
A
1
2
3
4
5
: Mounting screws with
washer, M3 x 6 (4 pls.)
: 24V DC (+)
: 24V DC (–)
: FG
: AC power input (U)
: AC power input (V)

Other M-system I/O System manuals

M-system R7D-TS4 User manual

M-system

M-system R7D-TS4 User manual

M-system Devicenet R7F4DD-DAC16C-H User manual

M-system

M-system Devicenet R7F4DD-DAC16C-H User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R7C-EC16B User manual

M-system

M-system R7C-EC16B User manual

M-system R7C-DS4N User manual

M-system

M-system R7C-DS4N User manual

M-system R7G4HEIP-6-DC16A User manual

M-system

M-system R7G4HEIP-6-DC16A User manual

M-system R7D-YS2A User manual

M-system

M-system R7D-YS2A User manual

M-system R30YN16A User manual

M-system

M-system R30YN16A User manual

M-system R7D-TS4/UL User manual

M-system

M-system R7D-TS4/UL User manual

M-system R3-SS8N User manual

M-system

M-system R3-SS8N User manual

M-system R7L-SV4 User manual

M-system

M-system R7L-SV4 User manual

M-system R7M-DAC16C-R User manual

M-system

M-system R7M-DAC16C-R User manual

M-system R8-SS4N User manual

M-system

M-system R8-SS4N User manual

M-system EtherCAT R7I4DECT-1-YVF4 User manual

M-system

M-system EtherCAT R7I4DECT-1-YVF4 User manual

M-system Remote I/O R8 Series User manual

M-system

M-system Remote I/O R8 Series User manual

M-system R7ML-DC16A-R User manual

M-system

M-system R7ML-DC16A-R User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system JC-IO User manual

M-system

M-system JC-IO User manual

M-system R30NE1 User manual

M-system

M-system R30NE1 User manual

M-system R7ML-SV4 User manual

M-system

M-system R7ML-SV4 User manual

M-system R80UST4 User manual

M-system

M-system R80UST4 User manual

M-system R8-PA4 User manual

M-system

M-system R8-PA4 User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R7ML-DC16B-R User manual

M-system

M-system R7ML-DC16B-R User manual

Popular I/O System manuals by other brands

Contec COM-1C-LPE user guide

Contec

Contec COM-1C-LPE user guide

HRW HPE8884MR manual

HRW

HRW HPE8884MR manual

MC PCI-DAS1001 user guide

MC

MC PCI-DAS1001 user guide

Fastwel DIC324 user manual

Fastwel

Fastwel DIC324 user manual

Unitronics UG-ULK-EIP-4A4BP6 user guide

Unitronics

Unitronics UG-ULK-EIP-4A4BP6 user guide

WAGO I/O SYSTEM 750 Quickstart Reference

WAGO

WAGO I/O SYSTEM 750 Quickstart Reference

National Instruments 9225E Operating instructions and specifications

National Instruments

National Instruments 9225E Operating instructions and specifications

Moxa Technologies ioThinx 4510 Series user manual

Moxa Technologies

Moxa Technologies ioThinx 4510 Series user manual

IFM Electronic AL19 operating instructions

IFM Electronic

IFM Electronic AL19 operating instructions

turck DM80-N quick start guide

turck

turck DM80-N quick start guide

Novus DigiRail-2A Communications manual

Novus

Novus DigiRail-2A Communications manual

Triax COFDM user guide

Triax

Triax COFDM user guide

Festo CPX Series Electronic manual

Festo

Festo CPX Series Electronic manual

Paso PM2093-VL Instructions for use

Paso

Paso PM2093-VL Instructions for use

Mitsubishi Electric AJ65SBTC1-32T1 user manual

Mitsubishi Electric

Mitsubishi Electric AJ65SBTC1-32T1 user manual

Weber PL751A Operation manual

Weber

Weber PL751A Operation manual

DAAB DB410 instruction manual

DAAB

DAAB DB410 instruction manual

National Instruments NI 9234E Operating instructions and specifications

National Instruments

National Instruments NI 9234E Operating instructions and specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.