manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R3-SV4 User manual

M-system R3-SV4 User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8366 Rev.5 P. 1 / 3
INSTRUCTION MANUAL
DC VOLTAGE INPUT MODULE
(4 points, isolated) MODEL R3-SV4
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
DC voltage input module ....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■UNUSED INPUT CHANNELS
• Set the unused channels to the ranges otherthan 1 – 5V.
Otherwise, set them as “Unused” with PC Configurator
software: R3CON. Unused channels left open with 1 – 5V
setting are equal to the input lower than -15%, which sets
a data abnormality at the PLC or the host device.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-SV4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8366 Rev.5 P. 2 / 3
COMPONENT IDENTIFICATION
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
■ FRONT VIEW ■ SIDE VIEW
ERR LED
RUN LED
Conv.
Rate
Input 2 (SW1)
or
Input 4 (SW2)
Range
Input 1 (SW1)
or
Input 3 (SW2)
Functions
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with input circuit abnormality (AD con-
verter response failure);
Green in normal operating conditions.
■SIDE DIP SW
(*)Factory setting
• Input Range: SW1, SW2
INPUT 1 (SW1) INPUT 2 (SW1)
RANGEINPUT 3 (SW2) INPUT 4 (SW2)
12345678
OFF OFF OFF OFF OFF OFF OFF OFF -10 – +10V (*)
ON OFF OFF OFF ON OFF OFF OFF -5 – +5V
OFF ON OFF OFF OFF ON OFF OFF -1 – +1V
ON ON OFF OFF ON ON OFF OFF 0 – 10V
OFF OFF ON OFF OFF OFF ON OFF 0 – 5V
ON OFF ON OFF ON OFF ON OFF 1 – 5V
OFF ON ON OFF OFF ON ON OFF 0 – 1V
• Conversion Rate: SW3-1, 3-2
SW CONVERSION RATE
80 ms (*) 40 ms 20 ms 10 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
Note: Be sure to set unused SW3-3 and 3-4 to OFF.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Unused 0: Enable
1: Disable
0: Enable
R3-SV4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8366 Rev.5 P. 3 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
■CONNECTION DIAGRAM
INPUT
1
11
1
12
+
–
2
–
NARROW SPAN
WIDE SPAN
+
INTERNAL POWER
*For dual redundant communication.
Note: Connect either wide or narrow span terminals for each channel.
BUS CONNECTOR
INPUT
2
13
3
14
+
–
4
–
NARROW SPAN
WIDE SPAN
+
INPUT
3
16
6
17
+
–
7
–
NARROW SPAN
WIDE SPAN
+
INPUT
4
18
8
19
+
–
9
–
NARROW SPAN
WIDE SPAN
+
INTERNAL BUS A
INTERNAL BUS B*
■Wide span: -10 – +10 V DC, -5 – +5 V DC, 0 – 10 V DC,
0 – 5 V DC, 1 – 5 V DC
■Narrow span: -1 – +1 V DC, 0 – 1 V DC
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.75 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)

Other M-system I/O System manuals

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7C-EC16B User manual

M-system

M-system R7C-EC16B User manual

M-system R7F4DC-DAC16D-H User manual

M-system

M-system R7F4DC-DAC16D-H User manual

M-system M5XPHS User manual

M-system

M-system M5XPHS User manual

M-system R30YN16A User manual

M-system

M-system R30YN16A User manual

M-system R30SV4 User manual

M-system

M-system R30SV4 User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R5-SS User manual

M-system

M-system R5-SS User manual

M-system Devicenet R7F4DD-DC16B-H User manual

M-system

M-system Devicenet R7F4DD-DC16B-H User manual

M-system R3-RS8B User manual

M-system

M-system R3-RS8B User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system R7C-DA16 User manual

M-system

M-system R7C-DA16 User manual

M-system R7G4HML-6-SVF8N User manual

M-system

M-system R7G4HML-6-SVF8N User manual

M-system 6BSN User manual

M-system

M-system 6BSN User manual

M-system R80UST4 User manual

M-system

M-system R80UST4 User manual

M-system R3-SV8 User manual

M-system

M-system R3-SV8 User manual

M-system R3S-RS4A User manual

M-system

M-system R3S-RS4A User manual

M-system R5T-RS User manual

M-system

M-system R5T-RS User manual

M-system M8BS1-16U0 User manual

M-system

M-system M8BS1-16U0 User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system Devicenet R7F4HD-DA32B User manual

M-system

M-system Devicenet R7F4HD-DA32B User manual

M-system R7HL-PA4E User manual

M-system

M-system R7HL-PA4E User manual

M-system R7F4HC-DAC32C-K User manual

M-system

M-system R7F4HC-DAC32C-K User manual

M-system M8BS2-042 User manual

M-system

M-system M8BS2-042 User manual

Popular I/O System manuals by other brands

TAC Xenta 411 Handbook

TAC

TAC Xenta 411 Handbook

Siemens 6DL2804 Series Hardware installation manual

Siemens

Siemens 6DL2804 Series Hardware installation manual

Pilz PSS u2 ES 4AI I operating manual

Pilz

Pilz PSS u2 ES 4AI I operating manual

Measurement Computing miniLAB 1008 user guide

Measurement Computing

Measurement Computing miniLAB 1008 user guide

National Instruments 9225 Operating instructions and specifications

National Instruments

National Instruments 9225 Operating instructions and specifications

Puls DIMENSION CT-Series manual

Puls

Puls DIMENSION CT-Series manual

Mitsubishi GT15V-75ROUT user manual

Mitsubishi

Mitsubishi GT15V-75ROUT user manual

Automationdirect.com Productivity 2000 P2-16NA manual

Automationdirect.com

Automationdirect.com Productivity 2000 P2-16NA manual

NK TECHNOLOGIES AGT Series instructions

NK TECHNOLOGIES

NK TECHNOLOGIES AGT Series instructions

Addi-Data APCI-3000 Technical description

Addi-Data

Addi-Data APCI-3000 Technical description

ICP DAS USA tET Series quick start guide

ICP DAS USA

ICP DAS USA tET Series quick start guide

ALLEN & HEATH DX88-P Getting started guide

ALLEN & HEATH

ALLEN & HEATH DX88-P Getting started guide

Sun Microsystems Fire 6800 Assembly Installation Guide

Sun Microsystems

Sun Microsystems Fire 6800 Assembly Installation Guide

Meilhaus Electronic ME-5001 manual

Meilhaus Electronic

Meilhaus Electronic ME-5001 manual

Valcom VE8048 quick start guide

Valcom

Valcom VE8048 quick start guide

Datexel DAT8016 Setup manual

Datexel

Datexel DAT8016 Setup manual

National Instruments PXI-7830R Getting started

National Instruments

National Instruments PXI-7830R Getting started

INVT EC-IO801 user manual

INVT

INVT EC-IO801 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.