manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R3-SV16N User manual

M-system R3-SV16N User manual

Other M-system I/O System manuals

M-system R7ML-DC16B-R User manual

M-system

M-system R7ML-DC16B-R User manual

M-system Devicenet R7F4HD-DC32A User manual

M-system

M-system Devicenet R7F4HD-DC32A User manual

M-system R7M-DC4G-R User manual

M-system

M-system R7M-DC4G-R User manual

M-system R7C-MS4 User manual

M-system

M-system R7C-MS4 User manual

M-system R7F4DC-DAC16C-H User manual

M-system

M-system R7F4DC-DAC16C-H User manual

M-system R3-BSW User manual

M-system

M-system R3-BSW User manual

M-system R7D-YV2/UL User manual

M-system

M-system R7D-YV2/UL User manual

M-system M6 Series User manual

M-system

M-system M6 Series User manual

M-system Remote I/O R8 Series User manual

M-system

M-system Remote I/O R8 Series User manual

M-system R3-DA8C User manual

M-system

M-system R3-DA8C User manual

M-system R30US4 User manual

M-system

M-system R30US4 User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system Devicenet R7F4DD-DAC16C-C User manual

M-system

M-system Devicenet R7F4DD-DAC16C-C User manual

M-system R7ML-TS4 User manual

M-system

M-system R7ML-TS4 User manual

M-system R3-SV8N User manual

M-system

M-system R3-SV8N User manual

M-system R7F4HEIP-DAC16B User manual

M-system

M-system R7F4HEIP-DAC16B User manual

M-system R8-YS2 User manual

M-system

M-system R8-YS2 User manual

M-system R5T-RS User manual

M-system

M-system R5T-RS User manual

M-system R5 Series User manual

M-system

M-system R5 Series User manual

M-system R7F4HC-DC32A-K User manual

M-system

M-system R7F4HC-DC32A-K User manual

M-system R7ML-DA16 User manual

M-system

M-system R7ML-DA16 User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system R30YN16C User manual

M-system

M-system R30YN16C User manual

M-system R7C-EC16B User manual

M-system

M-system R7C-EC16B User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

R3-SV16N
P. 1 / 3EM-8404 Rev.3
DC VOLTAGE INPUT MODULE
(16 points, non-isolated) MODEL R3-SV16N
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
DC voltage input module ............................................. (1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ HOT INSERTION/REMOVAL OF MODULES
Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ UNUSED INPUT CHANNELS
Set the unused channels to -10 – +10V range. Otherwise, set
them as “Unused” with PC Configurator software: R3CON.
Unused channels left open with other settings are equal to
the input lower than -15%, which sets a data abnormality at
the PLC or the host device.
■ AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-SV16N
P. 2 / 3EM-8404 Rev.3
■ STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the input circuit abnormality (AD
converter response failure);
Green in normal operating conditions.
■ SIDE DIP SW
• Input Range: SW1, SW2 (selectable per 8 channels)
INPUT 1 through INPUT 8 (SW1)
RANGEINPUT 9 through INPUT 16 (SW2)
1 2 3 4
OFF OFF OFF OFF -10 – +10V (*)
ON OFF OFF OFF -5 – +5V
ON ON OFF OFF 0 – 10V
OFF OFF ON OFF 0 – 5V
ON OFF ON OFF 1 – 5V
• Conversion Rate: SW3
SW CONVERSION RATE
100 ms (*)50 ms 20 ms 10 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
(*)Factory setting
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
■ FRONT VIEW ■ SIDE VIEW
ERR LED
RUN LED
Conv.
Rate Range
Input 1-8 (SW1)
or
Input 9-16 (SW2)
Functions
COMPONENT IDENTIFICATION
R3-SV16N
P. 3 / 3EM-8404 Rev.3
WIRING INSTRUCTIONS
■ SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit. Applicable
wire size: 0.3 – 0.5 mm2
3.2 (.13) dia.
4 min.
(.16)
12 (.47) max.
6 max.
(.24)
3 (.12) max.
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
INTERNAL POWER
BUS A
BUS B*
*For dual redundant communication.
BUS CONNECTOR
1
2
INPUT 1
3
4
INPUT 2
5
6
INPUT 3
7
INPUT 4
INPUT 5
INPUT 6
INPUT 7
INPUT 8
INPUT 9
INPUT 10
INPUT 11
INPUT 12
INPUT 13
INPUT 14
INPUT 15
INPUT 16
COM
COM
COM
COM
15
13
16
14
8
12
11
19
10
9
17
20
18
■ DIMENSIONS mm (inch)
■ CONNECTION DIAGRAM
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]