MAIN FEATURES
The smallest pump for the descaling of
wall-mounted boilers and boilers, equipped with
3-way valves, flow inverter and stand-by.
Low cost and high performances: with only 500
ml of descaling product DETEX Plus (diluted with
1500 ml of water), can be made up to 4 descaling
processes. The shoulder strap whose Boss Pulce
FI is equipped with, in addition to favour its car-
riage, guarantees the connection of the device to
the boiler that has to be descaled. It is equipped
with 2 corner connections that simplify the con-
nections to the heat exchangers, simplifying the
maintenance connections. BOSS PULCE FI has
been designed to offer to the user the maximum
safety, small dimensions the minimum weight
and the maximum handling: features that make
BOSS PULCE FI, a unique product on the mar-
ket. Reinforced and shock-proof polyethylene
tank, special pump with Viton® membrane,
self-priming and acid resistant pump.
ADVANTAGES
• Low price, high performances
• Small dimensions, minimum weight
• Maximum handling
• The lightest on the market
• Only 500 ml of liquid to work
TECHNICAL FEATURES
BOSS PULCE FI
Descaling pump for small heat
exchangers, hot water heaters,
boilers and wall-mounted boilers.
COD. 300601001
BENEFITS
• Restoring of the optimal heat exchange
• Reduction of energy consumption visible on
your bill
• Extension of system life
• Prevention of hot water total block
PACKAGING FEATURES
TANK 3,5 l
MAX FLOW RATE 8 l/min
CONNECTIONS 1/2"
MOTOR 12VD.C./D.C./0,04 kW
PRESSURE 3,5 bar
DEGREE OF PROTECTION IP 55
WEIGHT 3,5 kg
MAX TEMPERATURE 50° C
DIMENSIONS H: 270 mm L: 350 mm P: 170 mm
NUMBER OF PIECES PER BOX 1 pc
NUMBER OF PIECES PER EPAL PALLET 24
BOX DIMENSIONS H: 45 L:36 P: 40
EPAL PALLET DIMENSIONS 80x120x194 cm
PRODUCT WEIGHT 4,7 kg
BOX WEIGHT 5,5 kg
EPAL WEIGHT 152 kg
CUSTOMS CODE * 8413.82.00
BARCODE EAN 13 8054633849699
*Data updated in May 2016

APPLICATION AND USE
Pomp for the descaling of hot water heater, boilers, heat exchangers and wall-mounted boilers.
WHAT DO I NEED TO INSTALL IT
• Flexible pipes for an easier connection
• Nipples
• Connections
• Typical plumber's tool for connections of different type.
CORRECT INSTALLATION
1. As first thing (if it is possible) control if inside
the device that has to be descaled, there is
enough space to guarantee the passage for
the acid solution, the operation is not possi-
ble.
2. Disconnect the outlet and inlet of the device
to descale, if it is possible, drain it from the
internal water and then connect it to the
pump, through the use of equipped pipes.
3. Remove the tank cap and add water up to
half tank (please notice that operational
temperature during descaling must never
exceed 50 °C).
4. Connect the pump to the mains; switch it on
and start adding slowly descaling chemical,
until required concentration is obtained.
5. This operation guarantees the correct acid
product blending.
6. Please carefully follow use and safety in-
formation reported on the label of product.
Anyway, maximum operational time (con-
tinuously) of the motor, should not exceed
2 hours. Please after 2 hours, let the system
rest for at least half an hour.
ATTENTION: The flow inverter of the acid solu-
tion acting on the Flow Inverter (directional
valve) to obtain better results. Stand-by position
guarantees the flow interruption of the pump in
the circuit, when the boiler is very scaled and
there is a pressure increase verifiable through
the presence of noises due to higher frequency
of motor strokes.
1. Connection in/out pipes to the boiler
2. Pipes connection details
3. Pump correctly installed
3.
1. 2.
Note:
It is always suggested to connect the pump as
near as possible to the inlet and outlet of the
heat exchanger that has to be cleaned, in order
to avoid the damage of possible filters and/or
gaskets that are not resistant to acid action.
LEFT
INVERSION
RIGHT
INVERSION

EXPLODED VIEW AND SPARE PARTS
1 - TANK
2 - CAP
3 - CABLE GLANDS
4 - CHARGER
5 - MOTOR
6 - INOX BRACKET
7 - ½” – 3/8” NIPPLESE
8 - BELT WITH CARABINERS
9 - HOSE CONNECTOR
10 - CONNECTION PIPE
11 - TIPES
12 - PLASTIC CLAMPS
13 - DEVIATOR
14 - COMPLETED HOSE CONNECTOR
15 - MALE PLUG 8200 ½”
PACKAGING CONTENT
• 1 connections bag
• 1 User’s guide
• Connection pipes: 2,20m PVC pipe 10x15 – 2,30m PVC pipe 10x15
• Pump
MAINTENANCE
At the end of descaling operation:
1. Do not leave pump unattended during the operations.
2. Control the pH is included between 6,5 and 9,5. For the liquid neutralization, both the ones pres-
ent inside the pump, and also the ones present inside the descaled elements, we recommend to
use the neutralizing product Neutral Liquid or Neutral Powder.
3. Switch off the pump and disconnect as first thing the powder cord.
4. Wait till when the solution circulating inside the descaled device returns inside the tank.
DO NOT LEAVE ANY ACIDIC SOLUTION INSIDE THE TANK: fumes may seriously damage pump
components.

1. 2.
3. 4.
5. 6.
1. 2.
SIMILAR PRODUCTS
1. Boss 5 FI
COD. 300601002
2. Boss 18 FI
COD. 300601003
3. Boss 22 FI
COD. 300601005
4. Boss 36 FI
COD. 300601007
5. Boss 100 FI
COD. 300601009
6. Boss 200 FI
COD. 300601010
OPTIONAL
1. Buste terminali
COD. 300610001
2. Raccordi
COD. 300610003
3. HE Descaler Adaptor
COD. 300610004
3.

1. 3.2. 4.
TO BE USED WITH:
1. DETEX FE
5 kg - COD. 300501001
10 kg - COD. 300501002
20 kg - COD. 300501003
2. DETEX PLUS
1 kg - COD. 300501014
5 kg - COD. 300501004
10 kg - COD. 300501005
20 kg - COD. 300501006
3. DETEX Plurimetal
10 kg - COD. 300501011
20 kg - COD. 300501012
4. MANTEX POWDER
MULTI
1 kg - COD. 300501007
10 kg - COD. 300501008
5. MANTEX POWDER
ZN
1 kg - COD. 300501009
10 kg - COD. 300501010
6. NEUTRAL LIQUID
10 kg - COD. 300502001
7. NEUTRAL POWDER
1 kg - COD. 300502002
10 kg - COD. 300502003
5. 7.6.
OFFER DESCRIPTION
Descaling pump with membrane and ½” connections. Suitable to descale small heat exchangers, hot
water heaters, boilers, and wall-mounted boilers. Equipped with Flow Inverter. Tank of 3,5 litres.
Weight 3,5 kg. Small dimensions, contained weight and high manageability.

ORIGIN OF THE PRODUCT
Made in Italy
COMPLIANCE
This products mod. BOSS PULCE FI has been designed and constructed in accordance with the fol-
lowing European directives (including all applicable amendments):
Directive 2006/42/EC: Machine
Directive 2014/35/EU: Low Voltage
Directive 2014/30/EU: Electromagnetic Compatibility
Directive 2011/65/EC: RoHS 2
In addition, declares, that the electrical material used to made the product is in compliance with
Regulation CEI-EN 60034: Electrical rotating machines. Part 1: Nominal and operative features.
Boiler Performance by Manta Ecologica S.r.l.
Viale Archimede, 45 - 37059 - Zevio (VR)
www.boilerperformance.com
P.S. 343.01
Date of issue: 30/06/2016
Date of revision: 02/08/2016
Table of contents
Other Manta Water Pump manuals
Popular Water Pump manuals by other brands

EBARA
EBARA ESA300W instruction manual

Crane
Crane Barnes SGV 2 HP Service manual

Resol
Resol FlowSol B Installation, Operation, Commissioning, Maintenance

MULTIQUIP
MULTIQUIP QP4TB Operation manual

Elmo Rietschle
Elmo Rietschle C-VLR 62 OXY operating instructions

Gasboy
Gasboy 9120K Series Installation and operation manual

Wilo
Wilo Wilo-Stratos PICO Series Installation and operating instructions

Rietschle
Rietschle CLFG Series manual

STAR Water Systems
STAR Water Systems 4H05A05001 manual

Gardena
Gardena 5500/3 operating instructions

ULTIMATE SPEED
ULTIMATE SPEED 12 V UOP 12 C1 Operation and safety notes

Standard Pump
Standard Pump SP-CPVC operating instructions