19
Mareli Systems
CHRONO
This Manu allows selecting the programming modalities and and the Ignition/Extinguishing time slots.
Disable
Daily
Weekly
Week
-
End
Modality - It allows selecting the disired modality, or disable all set programming.
1. Enter modication mode through the key P3.
2. Select the chosen modality (Daily, Weekly or Week end).
3. Enable/disable chrono modality through the keys P2.
4. Save the settings through the keys P3.
Programming
The system includes three type of programming: Daily, Weekly, Week end.
After selecting the desired kind of programming:
1. Select the programming time through the keys P4/P6.
2. Enterthe adjustment modality (selected time will be ashing) through the keys P3.
3. Change the time via keys P4/P6.
4. Save the programmong with the keys P3.
5. Enable (a “V” is displayed) or disable the time slot (a“V” is not displayed”) by
pressing the keys P5.
Daily
Select the day of the week to program and set the ignition and extinguishing times.
Programs around midnight
Set the clock On of the previous day at the desired time: Ex. 20.30
Set the clock of OFF of the previous day at: 23:59
Set the clock On of the following day at 00:00
Set the clock of OFF of the following day at the desired time: Ex. 6:30
The system turns on at 20.30 on Tuesday and turns o at 6.30 on Wednesday
Weekly
The programs are the same for all days of the week.
Week-end
Choose between 'Monday-Friday' and 'Saturday-Sunday' and then set the switching
on and o times.
Monday
ON OFF
09:30 11:15 V
00:00 00:00
00:00 00:00
Tuesday
Wednesday
Thrusday
USER MENU 2
Menu is accessed by pressing the P3 buttons for 3 seconds .
Settings
Time and Date - Used to set the day, month, year and current time.
Language - Menu to modify the language of the LCD board.
Display Menu
Contrast - Menu used to regulate the display contrast.
Brightness - It allows you to adjust the screen brightness.
Minimum Brightness - Menu used to regulate the lighting of the display when the command aren’t used.
Keyboard Address - This Menu is protected by a password (the password is 1810), that allows you to set the RS485
node address. With the bus 485 it is not possible to have more nodes with the same address.
Sound - It allows you to enable or disable sound from the control panel.
Node List - This menu shows: communication address of the board, typology of the board, rmware code and
rmware version. Data are not modiable. The typologies of board that can appear are:
MSTR - Master; INP - Input; KEYB - Keyboard; OUT - Output;
CMPS - Composite; SENS - Sensor; COM - Communication;
Acoustic Alarm - It allows to enable or disable the acoustic alarm of the keyboard.
Auger Calibration - It allows to modify the value set in rm of Auger’s speed or On times. The values are in the
range – 7 ÷ 7. The rm’s value is 0.
Fan Calibration - It allows to modify the value set in rm of Combustion Fan’s speed. The values are in the range
– 7 ÷ 7. The rm’s value is 0.
Summer-Winter - This Menu allows you to modify the hydraulic plant functioning depending on the season.
USER MENU 2
Settings
Time and Date - It allows you to set day, month, year and current time.
Language - It allows you to modify the language of the keyboard.
Recipe - Menu for the selection of the combustion recipe.
Summer/Winter - Menu to edit the functioning of the hydraulic system according to the season.
Service
Counters - Ignitions (Number of attempted Ignitions) - Failed Ignition (Number of failed ignitions) -
Working hours (Operating hours in Run mode, Modulation and Safety).
Errors List - e menu shows the last 10 errors; in each line the error code and time/date of the error itself
are shown.
Secondary Information - Information about congurable outputs and inputs are only available if they have
been set.
Cleaning Reset - Menu to reset the function ‘System Maintenance 2’. It is displayed only if T67>0.
Auger Calibration - is menu allows you to modify the default values of the Auger speed or its On times.
You can set the values in a range within –7÷7. e default value is 0.
Fan Calibration - is menu allows you to modify the default values of the Combustion Fan speed. You can
set the values in a range within –7÷7. e default value is 0.
Mixer Valve - Menu to manage the Mixer Valve operation.
Automatic Power - is menu allows you to set combustion power in automatic mode only. If you set it,
power change menus are no longer displayed.
Loading - e procedure enables the pellet manual charge and it is automatically interrupted aer 300
seconds. In order to enable this function, the system must be on mode O.
Loading Test - e procedure allows calculating the amount of pellet used in 10 minutes with the auger.
Display
Contrast - It allows you to adjust the screen contrast.
Screen saver - is Menu allows the user to enable and disable the screen saver.
Acoustic Alarm - Menu to enable/disable the acoustic alarm.
Minimum Brightness - It allows you to adjust the screen brightness when not using the controls.