Mark-10 Corporation expressly warrants to its buyer for three (3) years
from the date of delivery that the goods sold are free from defects in
workmanship and materials. Mark-10 Corporation will, at its option,
repair or replace or refund the purchase price of goods found to be
defective. This remedy shall be the buyer’s sole and exclusive remedy.
Any modification, abuse, exposure to corrosive environment or use
other than intended will void this warranty. This warranty is in lieu of all
other warranties, including implied warranties of merchantability and
fitness for an intended purpose. In no event shall Mark-10 Corporation
be liable for any incidental and consequential damages in connection
with goods sold or any part thereof.
WARRANTY
User’s Guide
11-1042 OVERLOAD PROTECTION MODULE
09-1090 SET POINT CABLE
11-1042 OVERLOAD PROTECTION MODULE
11-1042 / 09-1090
SETTING UP
Both the 11-1042 overload protection module and 09-1090 share the
same dual connectors. Each connector is marked and should be con-
figured as follows:
A B
ESM, ESMH, TSTMH TSTM, TSFM500, TSFM500H,
TSFM1000, TSFM1000H
Test stand
model
This device is designed to prevent accidental overload to a Mark-10
gauge or sensor when used with any Mark-10 motorized test stand.
Applicable gauges are the BG, BGI, CG, and EG (if equipped with
optional outputs package). The module operates in both force and
torque applications.
Set the percentage of full scale of the gauge or sensor at which the
test stand is to stop moving by adjusting the two potentiometers on the
module with a Philips screwdriver. The percentage range is 20 - 110%
of full scale. See the illustration on the following page.
GAUGE
GAUGE
PC
PC
11-1042 09-1090 11-1042 09-1090
11-1042 MODULE
TO OUTPUT
CABLE
(OPTIONAL)
STAND
STAND
LIMITS
LIMITS
TO LIMIT
SWITCH
CABLE
(OPTIONAL)
TO TEST
STAND
TO
GAUGE
If using the overload protection module and 09-1090 set point cable
simultaneously, they should be configured as follows:
GAUGE
PC
TO
GAUGE
TO OUTPUT
CABLE
(OPTIONAL)
STAND
LIMITS
TO TEST
STAND
TO LIMIT
SWITCH
CABLE
(OPTIONAL)
REVERSE A
B
SELECT A OR B
ACCORDING TO
THE TABLE BELOW
User’s Guide
T / CCW
This setting applies to the tension
or counter-clockwise motion of the
test stand.
C / CW
This setting applies to the
compression or clockwise
motion of the test stand.
Once the percentages have been set, set up the test sample and pro-
ceed with the motorized test. When the force or torque threshold has
been reached, the stand will stop moving, the module will produce a
constant audible tone and the indicator below the potentiometer will be
lit. The tone and indicator light will not turn off until the force or torque
decreases to below the threshold value.
Note: It is highly recommended that the first test be per-
formed at low speed to ensure that the module is function-
ing properly.
09-1090 SET POINT CABLE
This cable is designed to stop the motion of any Mark-10 motorized
test stand travel at user-programmable set points with a BG, BGI, or
CG gauge. Refer to your gauge’s user’s guide for programming in-
structions.
Cable configuration instructions are provided on the previous page.

This manual suits for next models

1

Popular Cables And Connectors manuals by other brands

Ask HDSP0108N user manual

Ask

Ask HDSP0108N user manual

MAC Panel 7849211-30 Wiring Assembly Instructions

MAC Panel

MAC Panel 7849211-30 Wiring Assembly Instructions

Philips SPLITTER SWV3804 Specifications

Philips

Philips SPLITTER SWV3804 Specifications

DataComm Electronics 70-0078 Instruction/installation sheet

DataComm Electronics

DataComm Electronics 70-0078 Instruction/installation sheet

Keysight 16048A Operation and service manual

Keysight

Keysight 16048A Operation and service manual

Expondo MSW PRO-E 10 user manual

Expondo

Expondo MSW PRO-E 10 user manual

Festo MS9-12-ARMV Assembly instructions

Festo

Festo MS9-12-ARMV Assembly instructions

Optics LHM2-N Series user manual

Optics

Optics LHM2-N Series user manual

Thermon Fastrax Installation & operation manual

Thermon

Thermon Fastrax Installation & operation manual

Harwin KONA IS-49 instruction sheet

Harwin

Harwin KONA IS-49 instruction sheet

Philips SWV3020S/10 user manual

Philips

Philips SWV3020S/10 user manual

Global Cache Flex Link Serial Cable quick start

Global Cache

Global Cache Flex Link Serial Cable quick start

Spectrum Technologies 3660DP product manual

Spectrum Technologies

Spectrum Technologies 3660DP product manual

Eaton COOPER POWER SERIES installation instructions

Eaton

Eaton COOPER POWER SERIES installation instructions

Philips SWV2214 Specifications

Philips

Philips SWV2214 Specifications

Goobay 58979 user manual

Goobay

Goobay 58979 user manual

Lindy 38060/1 user manual

Lindy

Lindy 38060/1 user manual

Axis T8123-E Midspan 1-p user guide

Axis

Axis T8123-E Midspan 1-p user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.