6
VENTILATION
Localcodesandconditionsvarygreatlyfromoneareatoanotherandmustbecompliedwith.Thefollowing
aretheminimumrequirementsforgoodventilation.Pleaserememberthatthesearegeneral
recommendationsorguidelinesandyoumayhaveaspecialconditionorproblemthatwillrequirethe
servicesofaventilationengineerorspecialist.
PROPERVENTILATIONISTHEOVENOWNER’SRESPONSIBILITY.
Improperventilationwill
inhibitovenperformance,suchasthepilotgoingoutortheburningofthebottomofpies.
Marsal&Sons,Inc.cannotassumeresponsibilityforlossordamagesufferedasaresultofimproper
installation.
WARNING:
Failuretoproperlyventtheovencanbehazardoustothehealthofthe
operatorandmayresultinoperationalproblems,unsatisfactorybakingandpossible
damagetotheequipment.
Damagesustainedasadirectresultofimproperventilationwillnotbecoveredbythe
Manufacturer’swarranty.
CANOPYMETHOD
(Whentheexhaustfromtheovendumpsintothecanopyhood)
Theidealmethodofventingagasovenisthroughtheuseofaproperlydesignedventilationhoodwhich
extends10”‐12”infrontoftheoven.The
SHORTSTAINLESSSTEELFLUE
thatissuppliedwiththeoven
MUSTBEINSTALLED
.Placetheflueoverthecollarthatislocatedonthetopoftheovenandpressdown
untilitisfirmlylockedinplace.Theangleshouldfaceforwardandalwaysawayfromanyfilters.Astrong
exhaustfanwillcreateavacuumintheroom.Foranexhaustsystemtoworkproperly,replacementairmust
beintroducedintotheroom.Inthecaseofafilteredhood,thehoodmustbedesignednottopullexhaustout
oftheoven.
Thehoodshouldbesizedtocompletelycovertheequipmentplusanoverhangofatleast6”(15cm)onall
sidesnotadjacenttoawalland10”‐12”(25.4‐30.4cm)infrontoftheoven.Thedistancefromthefloorto
theloweredgeofthehoodshouldnotexceed7’(2.1m).
THERECOMMENDEDCFMFORTHEHOODISAPPROXIMATELY150CFMPERLINEARFOOT
Thecapacityofthehoodshouldbesizedappropriatelywithprovisionsforanadequatesupplyofmake‐upair.
DIRECTCONNECTIONMETHOD
(Whentheexhaustfromtheovenisdirectlyventedtotheoutside)
Anunrestrictedventpipethatprovidesexitairattheovenofaminimumof55CFMperovenmustbe
providedfortheventpipeatthetopoftheoven.Theventpipeshouldbeaminimumof6”indiameter.
A
DRAFTDIVERTER(ordrafthood)MUSTBEINSTALLEDforadirectventconnectionsysteminorderto
workproperly.Nomorethantwo90°elbowsshouldeverbeusedinadirectventconnectionandall
horizontalrunsmusthaveatleasta1”perfootpitch.