II InstallationI.
The BR may only be connected by a person authorized to operate electrical
installations Remember to choose the right protection
On the front of the BR , there are three LED indicators: green, red and blue.
On the side walls of the BR there are connection diagram and operating
characteristics
In order to connect the BR
make sure the electrical system is turned off
connect the RELAY according to the diagram fig fig in the options
> S1 control signal from L voltage
> S1 control signal from voltage N
> when using terminals 1-2 - after switching on, the receivers are turned off
> when using terminals 2-3 - after switching on, the receivers are turned on
switch on the supply voltage
> the green LED lights up
> after 1 s red LED and blue LED will blink
> after seconds, the blue LED will light up, which indicates closed contacts 2-3
Press the TEST button
> the blue LED turns off and the red LED turns on
> contacts 2-3 will open and contacts 1-2 will close
check operation with impulse button
> each subsequent press changes the voltage state on the receiver
and changing the LED lighting
blue contacts closed
red contacts closed
the efficiently operating installation is ready for operation
the pause between successive presses should not be less than ms
A schematic diagram of the operation of the BR is shown in Fig
The BR can work with an unlimited number of non illuminated buttons and a limited
number of illuminated buttons
- buttons illuminated with a typical neon (1mA) <10 pcs.
- LED illuminated buttons (0.1mA) <100 pcs.
-10
. .
-10
-10 :
.
-1 :
1.
2. ( .2, .3) :
3. :
4.
5.
:
- 2-3
- 1-2
6.
7. 200 .
8. -10 . 1.
-10 -
:
BISTABLE RELAY
BISTABLE RELAY
BISTABLE RELAY
BISTABLE RELAY 0
2
BISTABLE RELAY
BISTABLE RELAY
Fig An exemplary diagram of the connection of the BR
along with a table of possible connection variants
. 2. -10
.
BISTABLE RELAY
IV. Technical data
Rated supply voltage LN
Rated frequency
Maximum load current (power):
> resistive load
> incandescent lamps
> halogen lamps
> fluorescent lamps
> energy-saving lamps and LED
Instantaneous inrush current
Executive contacts
Rated power consumption
Short circuit current of impulse buttons-
Response time to the impulse button
Function check
Time to be ready again
Mechanical durability
Protection level
Cross section of connection cables-
Installation
Work position
Working temperature
Weight
230 V AC, + 10%, - 15%
50 Hz
16 A, AC1 (4 000 W)
10 A (2500 W)
8 A (2000 W)
8 A (2000 W)
8 A (2000 W)
100A
1 x NO, 1 x NC
0,5 W
5 mA
< 40 ms
TEST button
< 200 ms
100 000 operations
IP 20
0,2 2,5 mm÷ 2
One 18 mm field, 35 mm rail
Vertical
-25...+50 °C
80 g
Fig Schematic diagram of the operating principle of the BR. 1. -10.BISTABLE RELAY
t
t
t
t
S
TEST
Diagrams of possible variants of BR connections are shown in Fig-10 . 3.
N
L
16A
250VAC
(peak 100A)
1 2 3
23
1
BR-10
A1 A2
S
5 mA
S1
TEST
N
L
NL
N
L
A2
A1
S1