OPERATION GUIDELINES
When a AK4 combustion air assembly and a combustion air duct are attached to the connecting point on the
leftofthefireplace,combustion air may enter thefireboxthroughadampered opening behind the leftsidepanel.
This feature is designed for your benefit to reduce the room air used for combustion and to prevent excessive
lossof heat fromthe room. When thefireplace is inuse, this dampershould be open. Whenthe fireplace isnot
in use, the damper should be closed to prevent cold air from entering the firebox. The combustion air damper
is open when the lever, located on the left side of the firebox near the top of the left firebrick, is up and closed
when the lever is down.
Outside air for combustion is optional unless required by federal, state or local building codes. See the section
of this manual providing the instructions for installation of the combustion air assembly. The design of the
fireplaceallowsthe routing of thecombustion air duct up,down,or horizontally to obtainthe outside combustion
air. This permits flexibility in planning your installation. See Figure 23 for typical installation methods. Review
the precautions and recommendations in this manual pertaining to outside combustion air installation.
Glassdoors should be installed to receive themaximumbenefitfromyourfireplace. Forlargefires,themaximum
heating benefit from the fireplace will be obtained with the doors open due to the high amount of radiant heat
being emitted out of the front opening of the fireplace. With a small fire, or before retiring in the evenings, it is
best to operate the fireplace with the doors closed to prevent excessive room air form being drawn up the
chimney. When the doors are open, the mesh screens should be closed to help keep burning embers from
popping out of the firebox.
Thefireplaceshould also be equippedwith a flue damper, which mustbe open when thefireplaceis in use. The
flue damper control lever is located inside the fireplace. The counterweighted damper is operated by simply
pushingup to open orpulling down toclose the damper. Whenthe fireplace is not in use, thedamper should be
closed to prevent cold air form entering the chimney as well as preventing warm air in the room from escaping
up the chimney.
NOTE: It is normal for a small amount of smoke to be released from the upper portion of the fireplace the first
few times you use your new fireplace. This results from an oil residue on the metal. Open a door or window
to allow the smoke to escape.
Thegrate included with thisfireplace helps to appropriatelylocate and containthe burning wood. Failure touse
thisgrate may cause overheating ofparts of the fireplace and allow largepieces of burning wood to roll forward
out of the firebox. If the grate becomes warped or damaged, it must be replaced with grate number 050456
only.
WARNING: Fireplaces equipped with doors should be operated only with the doors fully open or doors fully
closed. If doors are left partly open, gas and flame may be drawn out of the fireplace opening, creating risks of
both fire and smoke.
All fireplace chimneys are in direct contact with cold air on the exterior of the structure. Consequently, when
the fireplace is not in use, cold air can fall down the chimney of the fireplace to cool off the fireplace chase.
Therefore, the fireplace chase must be insulated to minimize the risk of cold air infiltration to the home. Even if
the fireplace chase is adequately insulated, this cannot completely ensure that cold air infiltration into the
structurewill beeliminated. Coldairinfiltration isapossibilitywith anyfireplaceordevice thatfreelycommunicates
with the air on the outside of the structure. Today’s homes are more energy-efficient and, therefore, better
insulated and tightly constructed. Unfortunately, when air is removed from the house, as by a bathroom fan, or
consumed by a furnace, additional air is needed to replace the air consumed. Unless the additional air is
supplied, this can cause a negative pressure in the home. When this happens, the house will draw in outside
air form the cracks in the windows, down the fireplace flue or other locations of air leakage in the home.
Becausecold air infiltrationmay be unavoidablein some structures,Martin Hearth & Heating is not responsible
for heat loss or air infiltration through or around the fireplace.