TROUBLESHOOTING CLEANING MINERAL DEPOSITS
TROUBLESHOOTING
3. Using the program of pre-heating, put the metal funnel (no ground coffee inside) and a container
in place. Brew water per “ PRE-HEATING”.
4. Press the power switch to the lower position which is the “ ” position. The power indicator will
be illuminated. The appliance will start heating.
5. Press down the Coee/steam button to the higher position which is the “ ” position, waiting a few
seconds, until the ready indicator turns on which indicates pre-heating is finished.
6. Turn the operation knob to the “ ” position and make two cups of espresso (about 2 oz / 1/3 cup).
Then turn it to the“ ” position.
7. Press the coee/steam switch to the lower position which is the position, waiting a few seconds
until the ready indicator is illuminated. Turn the operation knob to the “ ”position and make steam
for 2 minutes, , then turn the operation knob to the “ ” position to stop making steam. Press the power
switch to the higher position to stop the unit immediately, and allow the descaler to remain in the unit
at least 15 minutes.
8. Restart the unit and repeat the steps of 4-7 at least 3 times.
9. Add tap water to the MAX level. Turn on the espresso maker (with no ground coffee) and brew.
Repeat steps of 4-7 three times (it is not necessary to wait for 15 minutes in step of 7), then brew
until no water is left in the tank.
Symptom
Water leaks from the bottom of
espresso maker.
Acid (vinegar) taste exists in
Espresso coffee.
There is a lot of water in the drip
tray.Please clean the drip tray.
The espresso maker malfunctions.
Espresso maker not properly
cleaned.
Ground coffee was stored in a hot,
damp place for a long time. Ground
coffee has turned bad.
Clean espresso maker following
steps in 'Before the First Use'
several times.
Please contact an authorized
service facility for repairing.
Cause Corrections
CLEANING MINERAL DEPOSITS
1. To ensure your espresso maker operates efficiently and coffee retains its peak flavour and the
internal piping is clean, the mineral deposits should be removed every 2 to 3 months.
2. Fill the tank with water and descaler to the MAX level (the scale of water and descaler is 4:1, the
detail refers to the instructions on the descaler. Please use “household descaler”, you can use the citric
acid (obtainable from a chemist’s or a drug store) instead of the descaler (the one hundred parts of
water and three parts of citric acid).
Always use fresh ground coee.
Store unused ground coee in a
cool, dry place. Reseal open
packages and store in refrigerator
to maintain freshness.
9