Matsusada Precision RMO Series User manual

Instruction Manual
MODEL RMOseries
19-inch Rack Mount Holder
B/N 174.9.020*174.9.020* Rev. 1.6

Note
◆All rights reserved.
◆
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted, in any form, or by any means, mechanical, electronic, photocopying,
recording, or otherwise, without the prior written permission of Matsusada Precision.
◆
No patent liability is assumed with respect to the use of the information contained herein.
Moreover, because Matsusada Precision is constantly striving to improve its high-quality
products, the information contained in this manual is subject to change without notice.
Every precaution has been taken in the preparation of this manual. Nevertheless,
Matsusada Precision assumes no responsibility for errors or omissions.
Neither is any liability assumed for damages resulting from the use of the information
contained in this publication.
Trademarks
◆Company names and product names in this document are the trademarks or registered
trademarks of their respective companies.
Warranty
◆For details, refer to the following website.
https://www.matsusada.com/support/manufacturer_warranty.html

i
RMO series
Page
1 Introduction ...........................................................................................................................................1
1-1 Introduction...............................................................................................................................................1
1-2 Overview...................................................................................................................................................1
1-3 Features....................................................................................................................................................1
1-4 Lineup.......................................................................................................................................................2
2 Before Use............................................................................................................................................3
2-1 Accessories..............................................................................................................................................3
2-2 Initial Inspection........................................................................................................................................3
2-3 Installation Condition................................................................................................................................3
2-4 Handling Precautions...............................................................................................................................3
3 External Appearance.............................................................................................................................4
3-1 Example of Installation.............................................................................................................................4
3-2 External Dimensions.................................................................................................................................7
3-2-1 RMO-133H-RK/-RK2/-RK3 (RK-80/R4K-80 series)................................................................................7
3-2-2 RMO-133H-RK/-RK2/-RK3 (R4K-36 series)...........................................................................................8
3-2-3 RMO-133H-RK400 (RK series 400W/800W/1200W).............................................................................9
3-2-4 RMO-133H-CO (CO series)..................................................................................................................10
3-2-5 RMO-150H-B (ES series) .....................................................................................................................11
3-2-6 RMO-133H-DRJ (DRJ series)...............................................................................................................12
3-2-7 RMO-44H-HALF (REKJ series)............................................................................................................13
3-2-8 RMJ-150H-EJC (EJC series)................................................................................................................14
3-2-9 RMO-133H-EPR (EPR series)..............................................................................................................15
3-2-10 RMO-177H-R4G (R4G series)............................................................................................................16
4 Installation and Connection .................................................................................................................17
4-1 Before Installation...................................................................................................................................17
4-2 Mounting on Holder................................................................................................................................ 17
4-2-1 RMO-133H-RK/-RK2/-RK3 (RK-80/R4K-80 series)..............................................................................17
4-2-2 RMO-133H-RK/-RK2/-RK3 (R4K-36 series).........................................................................................18
4-2-3 RMO-133H-CO (CO series)..................................................................................................................18
4-2-4 RMO-133H-RK400 (RK series 400W/800W/1200W)...........................................................................19
4-2-5 RMO-150H-B (ES series) .....................................................................................................................20
4-2-6 RMO-133H-DRJ (DRJ series)...............................................................................................................20
4-2-7 RMO-44H-HALF (REKJ series)............................................................................................................21
4-3 Wiring RMO-133H-RK/RK2/RK3............................................................................................................22
4-3-1 AC Wire Harness of RMO-133H-RK2/RK3...........................................................................................22
4-3-2 Fan Cable of RMO-133H-RK2..............................................................................................................23
4-3-3 Fan Cable of RMO-133H-RK3..............................................................................................................23
4-3-4 Installing Fan Unit .................................................................................................................................25
4-3-5 Installing Rack Mount Cover of RMO-133H-RK/RK2/RK3 ...................................................................25
4-3-6 Wiring Fan Unit of RMO-133H-RK/RK2/RK3........................................................................................26
Table of Contents

Page
5 Accessories.........................................................................................................................................27
5-1 Blank Panel.............................................................................................................................................27
5-2 Installing Blank Panel.............................................................................................................................27
5-2-1 RMO-133H-RK/RK2/RK3 (RK-80/R4K-80/R4K-36 series )..................................................................28
5-2-2 RMO-133H-RK400 (RK series: 400W/800W/1200W)..........................................................................28
5-2-3 RMO-133H-CO (CO series)..................................................................................................................28
5-2-4 RMO-150H-B (ES series) .....................................................................................................................29
5-2-5 RMO-133H-DRJ (DRJ series)...............................................................................................................29
5-2-6 RMO-177H-R4G (R4G series)..............................................................................................................30
5-2-7 RMO-133H-EPR (EPR series)..............................................................................................................31
5-2-8 RMO-150H-EJC (EJC series)...............................................................................................................31
5-2-9 RMO-44H-HALF (REKJ series)............................................................................................................32

1 Introduction
1
RMO series
1 Introduction
1-1 Introduction
Thank you for purchasing RMO series (19-inch rack mount holder).
Matsusada Precision takes every precaution to ensure the quality of our products. Please refer carefully
to this manual to use this product correctly and safely, and to achieve the best possible performance.
We have made every effort to provide all the necessary information in this manual. However, please do
not hesitate to contact us if you find any errors or omissions.
1-2 Overview
The RMO series is a rack mount adapter for our tabletop power supplies, electronic loads, and digital
controllers in a 19-inch rack.
The product is specially designed in accordance with Matsusada products to be installed, so it can be
easily used for installing them without measures against heat generation.
1-3 Features
•Specially designed for cooling so as not to affect the performance of the mounted devices. *1
•As for models employing built-in forced cooling fans, you have only to prepare a single cable to provide
power to drive the fan and the power supply.
•Perfect fit for the 19-inch rack cabinet lineup (RAC series). *2
*1 The intake temperature of the power supply unit should be within the operating temperature range. It
is generally known that more than 10C higher temperature than the operating temperature could cut
the service life in half.
*2 For details, contact our sales representatives.

1 Outline and Features
2
RMO series
1-4 Lineup
Model
Applicable power supplies
RMO-44H-HALF
REKJ/VOLJ
RMO-133H-RK*1 -RK2*1*2/-RK3*1*3*4
R4K-36/R4K-80/RK-80/EGS and CD (36Wor lower)
RMO-133H-RK400
RK/RZJR/EQ/TB and RKT (400W/800W)
RMO-133H-DRJ*5
DRJ/DRS/DJOP
RMO-133H-EPR
EG*7/ECD (48W or higher) /EPR
RMO-133H-CO
CO
RMO-150H-B*6
ES
RMO-150H-EJC
EJC
RMO-177H-R4G*1*6
R4G/R4GT
*1: Forced cooling fan attached. 115Vac (standard) / 230Vac (optional): 1 grounded cable 2.5 meters
supplied.
*2: Both the AC input cables of the main unit and the cooling fan can be put together as a whole one.
(Prepare AC wire harness separately.)
*3: Both the AC input cables of the main unit and the cooling fan together as a whole one. And the
[Power] switch ON/OFF on the power supply front panel can turn maximum 10 units ON/OFF at once.
(Prepare AC wire harness separately.)
*4: Some blank panels may be not used depending on number of power supply units to be installed.
*5: Note that DRJ series and DRS series with handles exceed 5.24 inches (133 mm) in height.
If you do not need the handle, select DRJ-LNh (option without handles).
*6: To increase the air flow, make space more than 10 cm. But, if it cannot be allocated, install a forced
cooling system.
*7 As EGD series can operate as a charge/discharge system combined with RK series
(400W/800W/1200W), they can be mixed and stored compactly in the holder.

2 Before Use
3
RMO series
2 Before Use
2-1 Accessories
After unpacking the box, check that the following accessories are supplied with the unit. If the
accessories are different, missing, or broken, please contact us immediately.
Model
Accessories
RMO-133H-RK400
RMO-133H-DRJ
RMO-133H-EPR
RMO-150H-B
RMO-150H-EJC
・Instruction Manual (this)
1 pc
RMO-44H-HALF
・Instruction Manual (this)
・Flat-head screw (M3 x 8)
・Display seal for input terminal
・Display seal for output terminal
1 pc
8 pcs
2 pcs
2 pcs
RMO-133H -RK
RMO-133H -RK2
RMO-133H -RK3
・Instruction Manual (this)
・AC cable for fan
1 pc
1 pc
RME-133H-CO
・Instruction Manual (this)
・Pan-head screw for fan unit (M3 x 6)
1 pc
22 pcs
RME-177H-R4G
・Instruction Manual (this)
・AC cable for fan
1 pc
1 pc
2-2 Initial Inspection
After unpacking the box, check the rack mount holder as well as the cover for scratches, dents, or other
damage on the unit caused by handling or transportation. If you find any abnormalities, please contact
the carrier and us.
2-3 Installation Condition
Install and use the unit in a horizontal orientation.
The intake temperature of the power supply unit should be within the operating
temperature range. It is generally known that more than 10C higher temperature
than the operating temperature could cut the service life in half.
Do not concentrate weight on the product when installing.
・DRJ series and DRS series with handles exceed 133 mm in height.
・RGJ series with handles exceed 149 mm in height.
2-4 Handling Precautions
Do not transport or install by a single person.
Do not attempt to install or remove by a single person.
When attaching the power supply unit to the rack mount, do not use longer screws
than 8 mm in length.
・Use the screws (M3 x 8) supplied for the plastic feet for installation.
・However, as for REKJ series, use the supplied pan-head screws (M3 x 8) for it.

3 External Appearance
4
RMO series
3-1 Example of Installation
RK-80/R4K-80/R4K-36 series
RK series (400W)
RK series (800W)
RK(800W): 2 units and Blank panel 140W: 1 piece (*Up to 3 units are available.)
(1)
(3)
(2)
RK series (1200W)
RK(1200W): 1 unit and Blank panel 210W: 1 piece (*Up to 2 units are available.)
(1)
(3)
(2)
(1) JIS pitch hole
(3) Blank panel (sold separately)
(2) EIA pitch hole
(4) Handles
3 External Appearance
O
F
RK-80: 5 units and Blank panel 35W: 5 pieces (*Up to 10 units are available. )
(1)
(4)
(3)
(2)
RK(400W): 3 units and Blank panel 70W: 3 pieces (*Up to 6 units are available.)
(1)
(3)
(2)

3 External Appearance
5
RMO series
CO series
CO-HV: 5 units and Blank panel 35W: 6 pieces (*Up to 11 units are available.)
(1)
(3)
(2)
ES series
ES: 4 units (*Up to 4 units are available.)
(1)
(2)
DRJ500 series
REKJ series
(1)
(3)
(2)
(1) JIS pitch hole
(3) Blank panel (sold separately)
(2) EIA pitch hole
DRJ500: 2 units and Blank panel 140W: 1 piece (*Up to 3 units are available.)
(1)
(3)
(2)
REKJ: 1 unit and Blank panel 210W: 1 piece (*Up to 2 units are available.)

3 External Appearance
6
RMO series
EJC series
EJC: 1 unit and Blank panel 212W: 1 piece (*Up to 2 units are available.)
(1)
(3)
(2)
EPR series
EPR: 3 units and Blank panel 84W: 2 pieces (*Up to 5 units are available.)
(1)
(2)
(3)
R4G series
EGD series
EGD: 3 units and Blank panel 84W: 2 pieces (*Up to 5 units are available.)
(1)
(2)
(3)
(1) JIS pitch hole
(3) Blank panel (sold separately)
(2) EIA pitch hole
R4G: 3 unitsand Blank panel 84W: 2pieces (*Up to 5 units are available.)
(1)
(2)
(3)

3 External Appearance
7
RMO series
3-2 External Dimensions
3-2-1 RMO-133H-RK/-RK2/-RK3 (RK-80/R4K-80 series)
Rear view

3 External Appearance
8
RMO series
3-2-2 RMO-133H-RK/-RK2/-RK3 (R4K-36 series)
Rear view

3 External Appearance
9
RMO series
3-2-3 RMO-133H-RK400 (RK series 400W/800W/1200W)

3 External Appearance
10
RMO series
3-2-4 RMO-133H-CO (CO series)

3 External Appearance
11
RMO series
3-2-5 RMO-150H-B (ES series)

3 External Appearance
12
RMO series
3-2-6 RMO-133H-DRJ (DRJ series)
For DRJ500-LNh

3 External Appearance
13
RMO series
3-2-7 RMO-44H-HALF (REKJ series)

3 External Appearance
14
RMO series
3-2-8 RMJ-150H-EJC (EJC series)

3 External Appearance
15
RMO series
3-2-9 RMO-133H-EPR (EPR series)

3 External Appearance
16
RMO series
3-2-10 RMO-177H-R4G (R4G series)
Table of contents
Popular Rack & Stand manuals by other brands

Amico
Amico RS-42-PKS Series Quick installation

Vicon
Vicon VM614RK-2 Installation & operation manual

Allen-Bradley
Allen-Bradley 2711-NP3 installation instructions

Victaulic
Victaulic VAPS1672 Operating and maintenance instruction manual

CablesPlus
CablesPlus SCM-1 quick start guide

HDX
HDX EH-WSTHDUS-021 Use and care guide