Electrical Connections Insure that all power components are connected securely. Connect control box either by means of an
approved moisture-resistant wall box or by leading an approved cable through the wall for connection outside the room. Use a
standard single gang flush mount outlet box. See the drawing for proper location of the outlet box. The wall outlet power supply is
120v 15 amp. Use GFI as required. The GFI control can be located at the wall panel or outlet. The product includes a built-in
24v/1amp transformer, 8’ power cord and 3-prong wall plug. Alternatively, product can be hard-wired directly into the electrical
power supply by a qualified, licensed electrician. Secure all cords/cables to protect users from tripping.
WARNING: Follow all instructions to avoid serious injury or product damage. If any parts are damaged, contact MAX-Ability. Do
not attempt to remove, modify, or repair damaged parts unless so instructed by MAX-Ability. Product should be installed by a
qualified professional, e.g., a licensed contractor. MAX-Ability is not liable for injury or damage caused by improper mounting.
● Use indicated dimensions to mount changing table..
● Please protect wall panel components from dust during installation.
Troubleshooting Should you experience any difficulty, verify the correct current, and check the power and hand
control plugs at the control box, making sure they are firmly connected. Check the operation manual for further
troubleshooting tips. Please contact MAX-Ability for assistance.
Subject to change without further notice
www.max-ability.com
800-577-1555 Fax: 707-575-3856 email: [email protected] rev. Feb 2017