Maxeon MAX3 Setup guide

SafetyandInstallationInstructions
UnitedStates
ThisdocumentappliestoMaxeonPVmodules
listedinTable1.
Contentsofthismanualaresubjecttochangewithoutnotice.
Forthelatestversionpleaserefertohttps://www.maxeon.com/us/InstallGuideUL
MaxeonSolarTechnologies,Ltd.
www.maxeon.com
Document544753Rev.A
ThisdocumentincludesreferencestoMAX3andMAX6modules.These
modulesdonothavegroundingrestrictionsandallarecompatiblewithhigh‐
efficiencytransformerlessinverters.

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document544753Rev.A
©2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedintheseinstructionsaresubjecttochangewithoutnotice.Page|2
SafetyandInstallationInstructions
(UnitedStates)
1.0 Introduction
TheseinstructionsprovidesafetyandinstallationinstructionsforUL
ListedMaxeonphotovoltaic(PV)modulesthathavetheULlogoonthe
productlabel:
1.1DisclaimerofLiability
Theinstallationtechniques,handling,anduseofthisproductarebeyond
companycontrol.Therefore,Maxeonassumesnoresponsibilityforloss,damage
orexpenseresultingfromimproperinstallation,handling,oruse.
1.2UnderwritersLaboratories(UL)ListingInformation
ThisproductmeetsorexceedstherequirementssetforthbyUL61730andUL
61215.TheseStandardscoverflat‐platePVmodulesandpanelsintendedfor
installationonbuildingsorthoseintendedtobefreestanding.Tosatisfythe
Listingforthisproductthemodulesmustbemountedwitharackorstandoff
structure.TheListingdoesnotincludeintegrationintoabuildingsurfacebecause
additionalrequirementsmayapply.Thisproductisnotintendedforusewhere
artificiallyconcentratedsunlightisappliedtothemodule.
1.3LimitedWarranty
ModulelimitedwarrantiesaredescribedinfullintheMaxeonwarranty
certificatesobtainableatwww.sunpower.maxeon.com.Insummary,theLimited
Warrantiesdonotapplytoanyofthefollowing:
PVModulessubjectedto:(i)misuse,abuse,neglectoraccident;(ii)alterationor
improperinstallation(improperinstallationincludes,withoutlimitation,
installationthatdoesnotcomplywithallMaxeoninstallationinstructionsand
operationsandmaintenanceinstructionsofanytype,asmaybeamendedand
updatedfromtimetotimeatMaxeon’ssolediscretion,andallnational,state,
andlocallaws,codes,ordinances,andregulations);(iii)repairormodificationby
someoneotherthananapprovedservicetechnicianofMaxeon;(iv)conditions
exceedingthevoltage,wind,snowload,andanyotheroperational
specifications;(v)powerfailureorsurges;(vi)indirectordirectdamagefrom
lightning,flood,fireorotheractsofnature;(vii)damagefrompersons,biological
activity,orindustrialchemicalexposure;or(viii)damagefromimpactorother
eventsoutsideMaxeon’scontrol.
1.4ProductSerialIdentification
SerialNumberRule:
WXXYZZZZZZZ
Where:
W–representsyearofmanufacture
XX–representstheweekofmanufacture
Y–representstheFactorylocation
ZZZZZZZ–uniqueidentificationnumberassignedtoeachmodule.
2.0 SafetyPrecautions
Beforeinstallingthisproduct,readallsafetyinstructionsinthisdocument.
AllinstallationsmustbeperformedincompliancewiththeNationalElectrical
Code(NEC)andanyapplicablelocalcodes.
ModulescertifiedtoUL61730areSafetyClass2forprotectionagainst
electricshock
Therearenouser‐serviceablepartswithinthemodule.Donotattemptto
repairanypartofthemodule.
Installationshouldbeperformedonlybyqualifiedpersonnel.
Donotstandon,drop,scratch,orallowobjectstofallonmodulesasdoingso
maydamagethemandvoidthewarranty.
Donotplaceanythingonthemodules,evenforamomentbecauseresulting
residuemaydamageorstaintheglasssurface.
Ifthefrontglassisbroken,orthebacksheetistorn,contactwithanymodule
surfaceormoduleframecancauseelectricshock. Damagedmodulesshould
beimmediatelydisconnectedfromtheelectricsystem.Themoduleshould
beremovedfromarrayassoonaspossibleandcontactthesupplierfor
disposalinstructions.
BrokenJ‐boxesorconnectorsareelectricalhazardsaswellaslaceration
hazards.Installersshouldremoveanysuchmodulefromthearrayand
contactMaxeonfordisposalinstructions.
Donotinstallorhandlethemoduleswhentheyarewetorduringperiodsof
highwind.
Donotblockdrainholesorallowwatertopoolinornearmoduleframes.
Maxeonrecommendsaconservativeminimumcablebendradiusofequalto
orgreaterthan40mm(1.5”).
Unconnectedconnectorsmustalwaysbeprotectedfrompollution(e.gdust,
humidity,foreignparticles,etc),priortoinstallation.Donotleave
unconnected(unprotected)connectorsexposedtotheenvironment.Aclean
assemblyenvironmentisthereforeessentialtoavoidperformance
degradation.
Donotallowtheconnectorstocomeincontactwithchemicalssuchas
greases,oilsandorganicsolventswhichmaycausestresscracking.
Donotdisconnectanymoduleswhenitsinverterisfeedingintothegrid.
Switchofftheinverterbeforedisconnecting,reinstallingormakinganyaction
withthemodules.
Forconnectors,whichareaccessibletountrainedpeople,itisimperativeto
usethelockingconnectorsandsafetyclips,ifapplicable,inordertodefend
againstuntrainedpersonneldisconnectingthemodulesoncetheyhavebeen
installed.
CoverallmodulesinthePVarraywithanopaqueclothormaterialbefore
makingorbreakingelectricalconnections.
Asthemodulesbendundertheload,donotmountsharpobjects(e.g.
screws)nearthemodulebackside.
Donotmountrailsunderthejunctionboxes
Donotattachoradhereitemsatthebacksheetofthemodules.
ContactMaxeonifmaintenanceisnecessary.
Savetheseinstructions!
2.1FireRating
ThemodulefireratingisType2perUL1703,2013edition.Firerating
classificationforanyPVsystemusingUL1703:2013canonlyestablishafirerating
incombinationwiththemountingsystemratingsnormallyfoundinthemounting
systeminstallationinstructions.
3.0 ElectricalCharacteristics
ElectricalcharacteristicsofthemodulesaredescribedinTable1below.Rated
electricalcharacteristicsarewithin10percentofmeasuredvaluesatStandard
TestConditionsof:1000W/m2,25°Ccelltemperatureandsolarspectral
DANGER!Moduleinterconnectioncablespassdirectcurrent(dc)and
aresourcesofvoltagewhenthemoduleisunderloadandwhenitis
exposedtolight.Directcurrentcanarcacrossgapsandmaycause
injuryordeathifimproperconnectionordisconnectionismade;or
ifcontactismadewithmoduleleadsthatarefrayedortorn.Donot
connectordisconnectmoduleswhenacurrentsourceisenergizing
theconductors.Modulesmaycontainhighvoltagewhen
interconnectedwithothermodules.
IMPORTANT!Pleasereadtheseinstructionsintheirentiretybefore
installing,wiring,orusingthisproductinanyway.Failuretocomply
withtheseinstructionswillinvalidatetheMaxeonLimitedWarranty
forPVModules.

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document544753Rev.A
©2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedintheseinstructionsaresubjecttochangewithoutnotice.Page|3
irradianceperIEC60904‐3orirradiationof(airmass)AM1.5global(G)spectrum.
Eachmodulecontainsthreebypassdiodes.Themaximumseriesfuseratingis
15A(X‐Series),forMAX3andMAX6modulesitis20A
Undernormalconditions,aphotovoltaicmodulemayexperienceconditionsthat
producemorecurrentand/orvoltagethanreportedatStandardTestConditions.
Accordingly,thevaluesofISCandVOCmarkedonULListedmodulesshould
alwaysbemultipliedbyafactorof1.25whendeterminingcomponentvoltage
ratings,conductorcapacities,fusesizesandsizeofcontrolsconnectedtothe
moduleoutput.RefertoSection690‐8oftheNECforanadditional1.25Safety
factorwhichmaybeapplicable.
Table1:ElectricalCharacteristics1
Module
Rated
Power
(W)
+5/‐0%
Voltage
atRated
Power
Vmpp
(V)
Current
atRated
Power,
Impp(A)
Open
Circuit
Voltage
Voc(V)
+/‐3%
Short
Circuit
Current,
Isc(A)
+/‐3%
Current
Temp.
Coeff.
%/°C
Voltage
Temp.
Coeff.
%/°C
Power
Temp.
Coeff.
%/°C
System
Safety
Class
SPR‐MAX3‐420‐BLK‐R 420 35.5 11.82 40.7 12.65 0.058 ‐0.236 ‐0.27 II
SPR‐MAX3‐415‐BLK‐R 415 35.3 11.75 40.7 12.64 0.058 ‐0.236 ‐0.27 II
SPR‐MAX3‐410‐BLK‐R 410 35.1 11.68 40.7 12.63 0.058 ‐0.236 ‐0.27 II
SPR‐MAX3‐430‐R 430 35.1 12.25 40.7 13.15 0.058 ‐0.236 ‐0.27 II
SPR‐MAX3‐425‐R 425 34.9 12.18 40.7 13.13 0.058 ‐0.236 ‐0.27 II
SPR‐MAX3‐415‐R 415 34.5 12.03 40.6 13.10 0.058 ‐0.236 ‐0.27 II
SPR‐MAX6‐480‐COM 480 44.2 10.87 52.6 11.58 0.060 ‐0.239 ‐0.30 II
SPR‐MAX6‐475‐COM 475 43.9 10.82 52.6 11.57 0.060 ‐0.239 ‐0.30 II
SPR‐MAX6‐460‐COM 460 43.2 10.64 52.5 11.54 0.060 ‐0.239 ‐0.30 II
SPR‐MAX6‐450‐COM 450 42.8 10.52 52.4 11.51 0.060 ‐0.239 ‐0.30 II
4.0 ElectricalConnectionsandSystemMonitoring
Modulesmaybeconnectedinseriesand/orparalleltoachievethedesired
electricaloutputaslongasoptimumdesignparametersareachieved.Pleaseuse
onlythesametypeofmodulesinacombinedsourcecircuit.Donotmixthe
moduleswithdifferentnameplateswithoutauthorizationbyMaxeon.
Evenifallowedbylocalregulation,PlugandSocketconnectorsmatedtogetherin
aPVsystemmustbeofthesametype(model,rating)fromthesame
manufactureri.e.aplugconnectorfromonemanufacturerandasocket
connectorfromanothermanufacturer,orviceversa,shallnotbeusedtomakea
connection.Currentlyapprovedcompatibleconnectorsare:Tyco,ModelPV4‐
S1M4/F4orStaubli,ModelPV‐KST4andKBT4/6II‐UR.
Maxeonrecommendsaconservativeminimumbendingradius(R)5xcable
diametermustbemaintainedandmustnotbebentonthedirectexitofthe
connectororjunctionbox.Avoidexposureofelectricalconnectionstodirect
sunlightanddonotplacetheconnectorinalocationwherewatercouldeasily
accumulate.Installersmustrefertoconnectormanufacturer’sinstructionfor
furtherinstallationandconnectionrequirements.
Connectorsarefactoryassembledwithintentionalgapsbetweenthecablenut
andthebodyoftheconnector.Donotretightenmoduleconnectornutsasthis
mayleadtostresscrackingoftheconnectorassemblyandwillvoidthewarranty.
4.1EquipmentGrounding
Toreducethepossibilityofelectricalshock,groundtheframeofthemoduleor
arrayperNECbeforewiringthecircuit.Inordertoinstallinaccordancewiththeir
ULListing,Maxeonmodulesmustbegroundedusinggroundinghardwarethat
meetsrequirementsforgroundingsystemsinUL61730andUL61215on
anodizedaluminumframes.Maxeonrecommendstorefertotheapplicable
regionalandlocalcodesandrequirementsongroundingPVarraysandmounting
framesinconjunctionwithyourrackingsupplier.
1Formodelsnotshownhere,pleasecontactMaxeontechnicalsupportorvisit
www.sunpower.maxeon.com.ElectricalparametersaremeasuredatStandardTest
Conditions(STC).Theseriesfusemusthaveaninterruptingratingthatisequaltoorgreater
thanthemaximumfaultcurrentthatthefuseisrequiredtointerrupt,includingcontributions
fromallconnectedsourcesofenergy.
RefertoNECArticle100,PartIIastowhattypeofseriesfuseisacceptableformodulesrated
athigherthan600Vdcsystemvoltage.
Inaddition,toavoidcorrosionduetotheuseofdissimilarmetalsMaxeon
recommendsstainlesssteelbetweencopperandaluminum.
4.2SystemGrounding
ReviewTable2belowforthepropergroundingtechniquesfortheinstallationof
yourparticularMaxeonmodules.
4.3SeriesConnection
Themodulesmaybewiredinseriestoproducethedesiredvoltageoutput.Do
notexceedthemaximumsystemvoltageshowninmoduledatasheetsand
productlabel.
4.4ParallelConnection
Themodulesmaybecombinedinparalleltoproducethedesiredcurrentoutput.
Eachseriesstringormodulemayberequiredtobefusedpriortocombiningwith
otherstringsiftheresultingmaximumfusesizeallowed(numberofmodules
whichcanbeconnectedinparallelandprotectedbyonefuse)exceedsthefuse
ratingasshowninthemoduledatasheetandproductlabel.Pleaserefertothe
NECArticle690foradditionalfusingrequirements.
Table2:ModuleGroundingKey
ModuleModelGroundingKey
MaxeonP‐Seriesmoduleshavenogroundingrestrictions:
AllmodelnumbersstartingwithSPR‐MAX3‐xxx‐R,SPR‐MAX3‐xxx‐BLK‐
R,SPR‐MAX6‐xxx‐COM
IMPORTANT!P‐Seriescanbegroundedwitheitherpolarity.Failureto
complywiththisrequirementwillreducesystemperformanceand
invalidateMaxeon’sLimitedPowerWarrantyforPVModules.
5.0 ModuleMounting
TheMaxeonLimitedWarrantyforPVModulesiscontingentuponmodulesbeing
mountedinaccordancewiththerequirementsdescribedinthissection.
5.1SiteConsiderations
Maxeonmodulesshouldonlybemountedinlocationsthatmeetthefollowing
requirements:
OperatingTemperature:AllMaxeonmodulesmustonlybemountedin
environmentsthatensuretheywilloperatewithinthefollowingtemperatures:
OperatingTemperaturerange(ambient)‐40°Cto+85°C
‐40°Fto+185°F
Adequateventilationshouldbeprovidedbehindthemodules,especiallyinhot
environments.
Shading:Modulesshouldbeinstalledsothatpermanentshadingofcellsis
avoidedandpartialshadingthatmayoccurduringcertaintimesofthedayor
yearisminimized. Permanentshadingisdefinedasshadethatiscastoverthe
sameposition(ofconstantarea)ofthesolarmodulethroughoutthegeneration
hoursoftheday.
Shadingmayinduceincertaincasesstrongenergyproductionreduction,evenin
caseofsmallshadingandshouldbeavoidasmuchaspossible,especiallyatmid‐
daywhentheproductionismaximum.
DesignStrength:Maxeonmodulesaredesignedtomeetapositive(downward)
and/ornegative(upward)withstandingtestpressureload,asperIEC61215,
whenmountedaspertheguidelinesinSection5.2andconfigurationsin
Appendix.Testloadsareforinformationpurposesonly;designloadsshouldbe
consideredfortheprojectdesign.
Whenmountingmodulesinsnowproneorhighwindenvironments,specialcare
shouldbetakentomountthemodulesinamannerthatprovidessufficient
designstrengthwhilemeetinglocalcoderequirements.
AdditionalauthorizedOperatingEnvironments:
Modulescanbemountedinthefollowingaggressiveenvironmentaccordingto
thetestlimitsmentionedbelow
Saltmistcorrosiontesting:IEC61701Severity6

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document544753Rev.A
©2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedintheseinstructionsaresubjecttochangewithoutnotice.Page|4
AmmoniaCorrosionResistance:IEC62716Concentration:6,667ppm
Modulesaredesignedforamaximumaltitudeof2000m.
ExcludedOperatingEnvironments
CertainoperatingenvironmentsarenotrecommendedforMaxeonmodules,and
areexcludedfromtheMaxeonLimitedWarranty. NoMaxeonmoduleshouldbe
mountedatasitewhereitmaybesubjecttodirectcontactwithsaltwater,or
otheraggressiveenvironment.
Modulesshouldnotbeinstallednearflammableliquids,gases,orlocationswith
hazardousmaterials;ormovingvehiclesofanytype.
5.2MountingConfigurations
Modulesintegratedintoormountedoveraroofingsystemmustbemounted
overafire‐resistantroofcoveringratedfortheapplication.Modulesmaybe
mountedatanyangle,fromhorizontaltovertical.Toreducesoiling,modules
shouldbemountedataminimumof5degrees.
Commercialmodules(128cells)frameshavepermanentlyattachedstackingpins
locatedina20mmzoneonthelongsideframeat388‐408mmfromthecorner.
Mountingsystemhardwareusedwithcommercialmodulesmustaccountforthe
presenceofthesestackingpins(seeAppendix).
Specificinformationonmoduledimensionsandthelocationofmountingand
groundingholesisprovidedinAppendix.Thesysteminstallerisresponsiblefor
thedeterminationoflocation‐specificloadrequirements.
Inordertopreventwaterfromenteringthejunctionbox,whichcouldpresenta
safetyhazard,modulesshouldbeorientedwiththejunctionboxinthe
uppermostpositionandnotbemountedsuchthatthecellfacesdownward(e.g.
onatrackingstructurethatpositionsthemoduleswiththejunctionboxfacing
skywardduringsleepmode).
ItshouldbenotedthatwatertightnessisnotensuredbyMaxeon,therefore,if
watermanagementisrequired,themountingsystemshouldbedesigned
accordingly.
Clearancebetweenthemoduleframesandstructureorgroundisrequiredto
preventwiringdamageandallowsairtocirculatebehindthemodule.Forall
modulesaminimumof1.5″ofclearancebetweenthemoduleframesandthe
structure(orgrade)isrequired.Therequiredminimumclearancebetween
installedmodulesis1/4″.
Wheninstalledonaroof,themoduleshallbemountedaccordingtothelocaland
regionalbuildingandfiresafetyregulations.Incasethemoduleisinstalledina
roofintegratedPV‐System(BIPV),itshallbemountedoverawatertightandfire‐
resistantunderlaymentratedforsuchapplication.
Modulesmountingsystemsshouldonlybeinstalledonbuildingsthathavebeen
formallyconsideredforstructuralintegrity,andconfirmedtobecapableof
handlingtheadditionalweightedloadoftheModulesandmountingsystems,by
acertifiedbuildingspecialistorengineer.
Mountingsystemsuppliershallmanagethegalvaniccorrosionwhichcanoccur
betweenthealuminumframeoftheModulesandmountingsystemorgrounding
hardwareifsuchdevicesiscomprisedofdissimilarmetals.
Themoduleisonlycertifiedforusewhenitsfactoryframeisfullyintact.Donot
removeoralterthemoduleframe.Creatingadditionalmountingholesor
removingthestackingpinsmaydamagethemoduleandreducethestrengthof
theframe,thereforearenotallowed.UsingmountingClampsorclipswith
additionalgroundingboltsorgroundingmetalsheetscouldbeincompliancewith
thisSafetyandInstallationInstructionsmanualsubjecttoconditionsofSection
4.1
Modulesmaybemountedusingthefollowingmethodsonly:
1) FrameHoles:Securethemoduletothestructureusingthefactory
mountingholes.Four1/4″stainlesssteelbolts,withnuts,washers,andlock
washersarerecommendedpermodule;tightenedtoamin.torqueof10in‐
lb.Thismethodhasbeencertifiedbyathird‐partyorganizationaccordingto
UL1703.Forframeholemounting,modulesmustbesecuredusingthe
holesshowninAppendix.
2) Clamps:Mountthemodulewiththeoppositeclampsonthelongerand/or
shortersidesofthemodule.Theclips
allowedlocationshouldbeaccording
toAppendix.Installersshouldensure
theclampsareofsufficientstrength
toallowforthemaximumdesign
pressureofthemodule.Clampsare
notprovidedbyMaxeon.Clampsmust
applyforcecollinearwiththe‘wall’of
themoduleframeandnotonlytothe
topflange.Clampsshallnotapply
excessiveforcetothetopframe,warpthetopflangeorcontacttheglass‐
thesepracticesvoidthemodulewarrantyandriskglassbreakage.Figure1a
illustrateslocationsfortopframeclampforce.Whenclampingtothe
moduleframe,torqueshouldneverexceed132in‐lbs(15Nm)toreduce
chancesofframedeformationand/orglassbreakage.Iftheclamp
manufacturerrecommendsaspecifictorquevaluewhichislowerthan132
in‐lbs(15Nm),theinstallershouldusetheclampmanufacturer’storque
value.Iftheclampmanufacturerrecommendsaspecifictorquevalue
whichishigherthan132in‐lbs(15Nm),theinstallershouldcontactthe
clampmanufacturerforacceptanceofthe132in‐lbs(15Nm)maximum
torquevalueortofindalternativeclamps.Acalibratedtorquewrenchmust
beused.Mountingsystemsshouldbeevaluatedforcompatibilitybefore
installing,especiallywhenthesystemisnotusingClampsorclip.
Maxeondoesnotrecommendnorendorsetheapplicationonthemodules
ofclampswhich,aspartoftheirgroundingorearthingfunction,haveteeth
orclawfeatureswhichmay,individuallyorcumulatively,causethemodule
breakagedueto(andwithoutlimitation):
i.thegroundingfeaturestouchingthefrontglasswhichisincorporatedinto
themoduleduetothepositionofsuchgroundingfeature,
ii.theshape,thepositionorthenumberofthegroundingfeatures
deformingthemoduletopframe,or
iii.theclampbeingover‐torquedduringtheinstallation.
Maxeonshallnotbeliableforanydamagesorlosseswhatsoeverarising
fromtheusebytheInstallerofanysuchclampsonitsmodules,and
disclaimsallwarranties,expressorimplied,applicabletothosemodules
shouldtheybedamagedinanywaybysuchclamps.Therefore,theuseof
theabovementionedclampsbytheInstallerisattheInstaller'ssolerisks.
5.2ModuleHandling
Donotplacemodulesfaceforwardindirectcontactwithabrasivesurfaceslike
roofs,driveways,woodenpallets,railings,stuccowalls,etc…
Themodulefrontsurfaceglassissensitivetooilsandabrasivesurfaces,which
mayleadtoscratchesandirregularsoiling.
Duringstorage,modulesneedtobeprotectedfromrainoranykindsofliquids.
Requiredstoragetemperatureisbetween10°Cto40°Cinadryenvironment
(humiditybetween30to80%).Donotstoremodulesoutdoortoavoidmoisture
andwetconditions.
Modulesthatfeatureantireflectivecoatedglassarepronetovisiblefingerprint
marksiftouchedonthefrontglasssurface.Maxeonrecommendshanding
moduleswithanti‐reflectiveglasswithgloves(noleathergloves)orlimiting
touchingofthefrontsurface.Anyfingerprintmarksresultingfrominstallation
willnaturallydisappearovertimeorcanbereducedbyfollowingthewashing
guidelinesinSection6.0below.Anymodulecoverage(coloredplastictarpsor
similar)duringinstallationcanleadtopermanentfrontglassdiscolorationandis
notrecommended.Theuseofvacuumliftingpadscancausepermanentmarks
Force must not deform
top frame flange or
glass may break
Force
has to
be
applied
in line
with
frame
wall
Figure 1a: Clamp Force Locations

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document544753Rev.A
©2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedintheseinstructionsaresubjecttochangewithoutnotice.Page|5
onthefrontglass.Neverliftormovethemoduleusingthecablesorthejunction
boxunderany‐circumstances.
Systemenergizationandshutdownproceduresneedtobefollowedbasedon
respectiveNationalguidelinesandlocalregulations.Safesiteoperational
practicesmustbeadheredbeforeenergizingthePVsystem(e.g.electrical
continuity,avoidingdirectcontactwithelectrical/framingequipment,wearing
safetyPPE,etc.).Systemshouldbeelectricallydisconnectedduringmaintenance,
upgrades,andmodificationworkswhichcanaffecttheoperationofPVsystem.
Systemsshouldbedisconnectedinanycasesofmaintenancewhichcancause
shading(e.g.chimneysweeping,anyroofmaintenance,antenna/dish
installations,etc).
6.0MaintenanceandCleaning
TrainedMaxeondealerortrainedMaxeonsupportpersonnelshouldinspectall
modulesannuallyforsafeelectricalconnections,soundmechanicalconnections,
andfreedomfromcorrosion.
Periodiccleaningofmoduleglasshasresultedinimprovedperformancelevels,
especiallyinregionswithlowlevelsofannualprecipitation;thereforeMaxeon
recommendsperiodiccleaningofthemodules.
Tocleanamodule,washitsglasssurfacewithpotable,non‐heatedwater.
NormalwaterpressureisadequatewhencleaningtheARglass.Some
fingerprints,stains,oraccumulationsofdirtontheglassmayberemovedwith
over‐the‐counterglasscleaners(suchasWindex®orequivalent),orwitha3%
soap‐and‐watersolution.Forsmallersystems,wetthemoduleglasswiththe
solution,letitstandforfiveminutes,andthenwetthemagainanduseasoft
spongeorseamlessclothtowipetheglasssurfaceinacircularmotion.Forlarge
systems,wetthemoduleswiththecleaningsolution,letthemstandforfive
minutes,andthenrinsethemwithhigh‐pressurewaterorasoftsqueegee.Do
notuseharshindustrial‐strengthcleaningmaterialssuchasscouringpowder,
steelwool,scrapers,blades,orothersharpinstrumentstocleanthemodule
glass.Useofsuchmaterialswillvoidtheproductwarranty.
Recommended Cable Management
Portrait Stringing
Leapfrog Stringing (Portrait)
Maxeon Product Line:
Landscape Stringing

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document544753Rev.A
©2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedintheseinstructionsaresubjecttochangewithoutnotice.Page|6
Appendix: Mounting Configurations and Load Ratings
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 150
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 272
50 - 150
150 - 272
272 - 453
453 - 710
50 - 150
150 - 272
272 - 453
453 - 710
0 - 350
0 - 350
+2700/-2700
+2700/-2700
+2700/-2700 +1800/-1800
+1800/-1800
+1800/-1800
+3600/-3600
+5400/-4200
+3600/-3600
+2700/-2700
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+2400/-2400
+3600/-2800
+2400/-2400
+1800/-1800
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
TOP CLAMPS
Maxeon 3 112 cells AC Ready Solar Panel
(SPR-MAX3-XXX-R, SPR-MAX3-XXX-BLK-R, SPR-MAX3-XXX-COM-R)
GEN 5.2 FRAME PROFILE
SIDE FRAME PROFILE END FRAME PROFILE
A - Ground Holes (4X Ø4.2mm)
B - Mounng Holes (8X Ø6.8mm)
1046 mm [41.8in]
1002 mm [39.43in]
1100 mm [43.31in]
1300 mm [51.18in]
1656 mm [65.17in]
1812 mm [71.34in]
0
B
272
[10.71] 453
[17.83]
150
[5.91] 710
[27.95]
0
272
[10.71]
453
[17.83] 150
[5.91]
710
[27.96]
0
350
[13.78]
0
A
50
[1.97]
50
[1.97]
350
[13.78]
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1300mm Holes
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
+5400/-5400
+5400/-5400
+5400/-5400
+3600/-3600
+3600/-3600
+3600/-3600
1100mm Holes
BOLTS
1300mm Holes
1100mm Holes +5400/-5400 +3600/-3600
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
4 Rails must not be under the juncon box.
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
CoveredunderIEC 61730 Cert Testfor 104 cell
5 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
0 - 350
272 - 453
453 - 710
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Tes t Lo ad
Downward/Upward
(Pa)
Tes t Lo ad
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
32 mm
[1.26in]
40 mm
[1.57in]
40 mm
[1.57in]
24 mm
[0.94in]
6 Boom flange mounng.

MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document544753Rev.A
©2022MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedintheseinstructionsaresubjecttochangewithoutnotice.Page|7
GEN 5.6 FRAME PROFILE
A - MLSD Holes
B - Mounng Holes (16X Ø6.8mm)
C - Ground Holes (4X Ø4.2mm)
Maxeon 6 72 cells Commercial Solar Panel
(SPR-MAX6-XXX-COM)
1039 mm [40.91in]
995 mm [39.17in]
400 mm
[15.74in]
1200 mm [47.24in]
1423 mm [56.02in]
1653 mm [65.08in]
2047 mm [80.59in]
0
ABC
SIDE FRAME PROFILE END FRAME PROFILE
50
[1.97]
0
50
[1.97]
296
[11.65]
536
[21.10] 150
[5.91]
825
[32.48]
0
0
350
[13.78]
32 mm
[1.26in]
35 mm
[1.38in]
32 mm
[1.26in]
35 mm
[1.38in]
350
[13.78]
825
[32.48]
536
[21.10]
296
[11.65]
150
[5.91]
Mounng Configuraon Diagram
Front View Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 150
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 296
296 - 536
536 - 825
50 - 150
150 - 296
296 - 536
536 - 825
50 - 150
150 - 296
296 - 536
536 - 825
0 - 350
0 - 350
0 - 350
+2400/-1600
+1800/-1600
+1800/-1600 +1200/-1067
+1200/-1067
+1600/-1067
+2400/-2400
+5400/-2400
+2400/-2400
+1800/-1800
+2400/-2400
+5400/-2400
+2400/-2400
+1800/-1800
+2400/-2400
+5400/-2400
+2400/-2400
+1800/-1800
+1600/-1600
+3600/-1600
+1600/-1600
+1200/-1200
+1600/-1600
+3600/-1600
+1600/-1600
+1200/-1200
+2600/-1600
+3600/-1600
+1600/-1600
+1200/-1200
TOP CLAMPS/INVISIMOUNT
Tes t Loa d
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Mounng
Configuraon
Descripon
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Mounng Configuraon Diagram
Front View Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1423mm Holes
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
1200mm Holes
400mm Holes
+2500/-2400
+5400/-5400
+5400/-5400
+2400/-2400
+5400/-6000
+5400/-6000
+1600/-1600
+3600/-3600
+3600/-3600
+1600/-1600
+3600/-4000
+3600/-4000
1423mm Holes
1200mm Holes
400mm Holes
BOLTS
Tes t Loa d
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Mounng
Configuraon
Descripon
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
3 This configuration was cert tested to +9000/-4500 Pa
Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
4 Rails must not be under the juncon box.
5 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
6 Boom flange mounng
This manual suits for next models
11
Table of contents
Other Maxeon Control Unit manuals
Popular Control Unit manuals by other brands

ABB
ABB ACS880-04F Hardware manual

Roland
Roland XV-3080 Turbostart

Harvia
Harvia XAFIR CS170 Instructions for installation and use

praher
praher AquaStar easy 1000 operating manual

Bandini Industrie
Bandini Industrie Gi.Bi.Di. BA24 Instructions for installations

Nice
Nice WA20/A Instructions and warnings for installation and use