When turn the knob 5, the boiler doesn't ignite in
10 seconds, the red indicator 3 lights.
Check the gas valve is opened or not, press the
RESET knob to restart the boiler to ignite once
more, if the boiler still doesn't start up, turn off the
boiler and ask for technician.
When the input/output power is normal, the
temperature is too high the boiler will show
the overheating malfunction.
The causations are as follow:
• Water lackage in heating system. Check
the pressure is during the 1-1.2bar or not.
• The circulation in the heating system is not
so smoothly, check the pipeline in the
sealed heating system and air vent works or
not.
• To restart the boiler, please turn the knob 4
to the RESET If this malfunction happened
continully, turn off the boiler and ask for
technician.
Air pressure sensor malfunction—red
indicator 3 lights and the yellow indicator 2
lights
In this situation, check the air inlet
pipe, the exhaust gas pipe and the fan. If
necessary, turn off the boiler and ask for
technician.
CdUtion: Maintenance should be taken by
technician.
Gas smell. The gas has leaked, so the pipe
should be checked if sealed.
When the fan is operationg, the flame can't cover
the burner. Maybe the fan has started, but the
point of the air pressure sensor hasn't changed. It
need examination.
The inlet-exhaust gas pipe is too long that has
exceed the size permision;
The inlet-exhaust gas pipe is blocked.(Maybe the
part of the inlet pipe and the part of the exhaust
pipe.)
The isolation ring is not fitted to the inlet-exhaust
gas pipe;
The sealed box is not sealed well.
The power of the fan is lower than 196V.
The burning is abnormal that the flame is red or
yellow. The causation are as follows. The burner
is too dirty. The wrong tie-in terminal..
Over temperature and the pressure meter shows
frequently boiler malfunction.This is caused by
the lack of system water, the abnormal heating
system water circulation and the block in the
circulation system. Check the pressure meter to
ensure the pressure is under 1-1.2bar. Be sure
that the valve of the heating system are all closed
and the operation of the circulation system is
normal.
The air is not emptied in the system. Check the
safe valve to be opened, the pressure of the
boiler and the expansion vessel at the ranged
pressure. The pressure of the expansion vessel
should be at LObar, the pressure of the boiler
should be at 1-1.2bar.
The circulation pump maybe blocked because it
is not used for a long time. Please disassemble
the front of the pump, running the motor base by
screwdrive. Do this carefully.