PRODUCT MODEL NUMBERS
MGDE400X, MGDE500W
Gas supply: This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid
pipe is used it should be 1/2" IPS. When acceptable
to the gas supplier and local codes, 3/8" approved
tubing may be used for lengths under 20 ft (6.1 m).
For lengths over 20 ft (6.1 m), larger tubing should be
used. Pipe-joint compounds resistant to the action of
L.P. gas must be used. An individual manual shutoff
valve must be installed within 6 ft (1.8 m) of the dryer
in accordance with the National Fuel Gas Code ANSI
Z223.1.
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp
fused electrical supply is required. A time-delay fuse or
circuit breaker and a separate circuit are recommended.
Water (Steam models only): The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or exible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
The vent system chart provides venting requirments
that will help to achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.
4"
(102 mm)
2½"
(64 mm)
4"
(102 mm)
4"
(102 mm)
B
A
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
C
Number of
90 turns
or elbows
Ty pe of
vent
Box or
Louvered
hoods
Angled
hoods
0Rigid metal 64 ft (20 m) 58 ft (17.7 m)
154 ft (16.5 m) 48 ft (14.6 m)
244 ft (13.4 m) 38 ft (11.6 m)
335 ft (10.7 m) 29 ft (8.8 m)
427 ft (8.2 m) 21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
14
"
(356 mm)
3
7
/
16
"
(87 mm)
1
"
(25 mm)
7
5
/
8
"
(194 mm)
3
3
/
8
"
(86 mm)
1
"
(25 mm)
Back View Side View
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Ref. W10255469B
06/2010
OVERALL DIMENSIONS
27
"
(686 mm)
38
"
(965 mm)
NON-STEAM - 511/2
"
(1308 mm)
STEAM - 529/16
"
(1335 mm)
NON-STEAM - 311/2
"
(800 mm)
*STEAM - 329/16
"
(827 mm)
†
27
"
(686 mm)
38
"
(965 mm)
1
"*
(25 mm)
1
"*
(25 mm)
0
"
(0 mm)
(460 mm)
NON-STEAM - 5
"*
STEAM - 5
1
/
2
"*
27
"
(686 mm)
1
"
(25 mm)
76
"
(1930 mm)
6
"*
(152 mm)
NON-STEAM - 31
1
/
2
"
STEAM - 32
9
/
16
"
1
"*
(25 mm)
5
"**
(127 mm)
1
"
(25 mm)
3
"*
(76 mm)
3
"*
(76 mm)
48
"2*
(310 cm2)
48
"2*
(310 cm2)
(800 mm)
(827 mm)
(140 mm)
(127 mm)
(229 mm)
5
"**
(127 mm)
9
"*
(229 mm)
7
"*
(178 mm)
7
"*
(178 mm)
1
"*
(25 mm)
1
"*
(25 mm)
27
"
(686 mm)
1
"*
(25 mm)
NON-STEAM - 311/2
"
STEAM - 329/16
"
(800 mm)
(827 mm)
NON-STEAM - 31
1
/
2
"
*
STEAM - 32
9
/
16
"
*
(800 mm)
(827 mm)
Custom undercounter installation-dryer only
Dryer dimensions
† Most installations require a minimum
5" (127 mm) clearance behind the dryer for
the exhaust vent with elbow. See Installation
Instructions, “Venting Requirements.”
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Do not use vent runs longer than specied in vent length chart.
Determine the number of elbows you will need.
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
For cabinet installation, with a door, the minimum ventilation openings in the top
are required.
*Required spacing **For side or bottom venting, 2" (51 mm) spacing is allowed.

This manual suits for next models

1

Other Maytag Dryer manuals

Maytag MED5870TW1 User manual

Maytag

Maytag MED5870TW1 User manual

Maytag MGDE251YG0 User manual

Maytag

Maytag MGDE251YG0 User manual

Maytag MGD6000XG0 User manual

Maytag

Maytag MGD6000XG0 User manual

Maytag MDG7400AWQ User manual

Maytag

Maytag MDG7400AWQ User manual

Maytag W10385090A User manual

Maytag

Maytag W10385090A User manual

Maytag NEPTUNE MD68 User manual

Maytag

Maytag NEPTUNE MD68 User manual

Maytag MGDZ600TB2 User manual

Maytag

Maytag MGDZ600TB2 User manual

Maytag MDE17MNBGW User manual

Maytag

Maytag MDE17MNBGW User manual

Maytag MDG50PNH User manual

Maytag

Maytag MDG50PNH User manual

Maytag MEDE201Y User manual

Maytag

Maytag MEDE201Y User manual

Maytag MD-15 User manual

Maytag

Maytag MD-15 User manual

Maytag MED5720TQ0 User manual

Maytag

Maytag MED5720TQ0 User manual

Maytag PY-1 User manual

Maytag

Maytag PY-1 User manual

Maytag MD-24 User manual

Maytag

Maytag MD-24 User manual

Maytag MEDC300BW User manual

Maytag

Maytag MEDC300BW User manual

Maytag 29" User manual

Maytag

Maytag 29" User manual

Maytag S-8 User manual

Maytag

Maytag S-8 User manual

Maytag MED7500YW User manual

Maytag

Maytag MED7500YW User manual

Maytag MLG34 Administrator Guide

Maytag

Maytag MLG34 Administrator Guide

Maytag 4KMEDX505BW0 User manual

Maytag

Maytag 4KMEDX505BW0 User manual

Maytag BRAVOS MEDB200VQ0 User manual

Maytag

Maytag BRAVOS MEDB200VQ0 User manual

Maytag MED5600TQ0 User manual

Maytag

Maytag MED5600TQ0 User manual

Maytag YMEDB755DW1 User manual

Maytag

Maytag YMEDB755DW1 User manual

Maytag MGD6400TB - Bravos Gas Dryer User manual

Maytag

Maytag MGD6400TB - Bravos Gas Dryer User manual

Popular Dryer manuals by other brands

Alliance Laundry Systems 505048R2 Installation and operation

Alliance Laundry Systems

Alliance Laundry Systems 505048R2 Installation and operation

Kenmore 110C79592800 User instructions

Kenmore

Kenmore 110C79592800 User instructions

GE Profile DNSB514 owner's manual

GE

GE Profile DNSB514 owner's manual

GE GTX33EASK Dimensions and installation information

GE

GE GTX33EASK Dimensions and installation information

Frigidaire FFQG5000QW Features

Frigidaire

Frigidaire FFQG5000QW Features

Bosch WPG23100IN User manual and installation instructions

Bosch

Bosch WPG23100IN User manual and installation instructions

Bosch WTG86403UC Use and care manual / installation instructions

Bosch

Bosch WTG86403UC Use and care manual / installation instructions

Equator ED 620 owner's manual

Equator

Equator ED 620 owner's manual

Hitachi TD-80YFE instruction manual

Hitachi

Hitachi TD-80YFE instruction manual

Zanussi TD 4213 W Instruction booklet

Zanussi

Zanussi TD 4213 W Instruction booklet

GE DPGT750ECPL - Profile Harmony 7.3 cu. Ft. Electric... owner's manual

GE

GE DPGT750ECPL - Profile Harmony 7.3 cu. Ft. Electric... owner's manual

Bosch WTW84469GR Installation and operating instructions

Bosch

Bosch WTW84469GR Installation and operating instructions

American Dryer Corp. AD-100 Installation/service parts

American Dryer Corp.

American Dryer Corp. AD-100 Installation/service parts

AEG LAVATHERM 9DEC87S user manual

AEG

AEG LAVATHERM 9DEC87S user manual

LG DLEX0001TM User's guide & installation instructions

LG

LG DLEX0001TM User's guide & installation instructions

GE GTDS820GDWS Dimensions and installation information

GE

GE GTDS820GDWS Dimensions and installation information

Siemens WT47XMH1EU User manual and installation instructions

Siemens

Siemens WT47XMH1EU User manual and installation instructions

JetDryer Business2 instruction manual

JetDryer

JetDryer Business2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.